GENERATOR

Owner’s Manual

H i

FM

AH

PANTONE

186C

K

背幅4.6mm

EU2200i / EU2200i

Companion

Companion

See page 13 for Initial Use Instructions

2020 Honda Motor Co., Ltd. -All Rights Reserved    

C

Summary of Contents for EU2200i

Page 1: ...hailand 31Z44610 00X31 Z44 6100 GENERATOR Owner s Manual H i FM AH 英 PANTONE 186C K 背幅4 6mm EU2200i EU2200i Companion Companion See page 13 for Initial Use Instructions 2020 Honda Motor Co Ltd All Rights Reserved C ...

Page 2: ...ations or design at any time without notice and without incurring any obligation whatsoever The illustration may vary according to the type Theengineexhaustfromthisproduct contains chemicalsknownto the Stateof Californiato cause cancer birth defects or other reproductiveharm Exhaust contains poisonous carbon monoxide gas that can build up to dangerous levels in enclosed or partly enclosed areas Br...

Page 3: ...e page 85 to fully understand its coverage and your responsibilities of ownership When your generator needs scheduled maintenance keep in mind that your Honda servicing dealer is specially trained in servicing Honda generators and is supported by the parts and service divisions of American Honda Your Honda servicing dealer is dedicated to your satisfaction and will be pleased to answer your questi...

Page 4: ...ions how to use this generator correctly and safely Safety Headings such as IMPORTANT SAFETY INFORMATION Safety Messages preceded by a safety alert symbol and one of three signal words DANGER WARNING or CAUTION These signal words mean This entire book is filled with important safety information please read it carefully DAMAGE PREVENTION MESSAGES In addition to the above you will find information p...

Page 5: ...TURES 19 COMPONENT CONTROL LOCATIONS 19 CONTROLS 21 Engine Switch 21 Starter Grip 21 Fuel Filler Cap Vent Lever 22 Choke Lever 22 Eco Throttle Switch 23 CO MINDER CO Shut off System 24 Parallel Operation Outlets 26 AC Circuit Protector 27 FEATURES 28 Ground Terminal 28 Output Indicator 29 Overload Alarm Indicator 30 Oil Alert Check Indicator 30 LED Light Patterns 31 Bluetooth Function 32 Smartphon...

Page 6: ...Operation Applications 50 ECO THROTTLE SYSTEM 53 STANDBY POWER 54 Connections to a Building s Electrical System 54 System Ground 54 Special Requirements 55 SERVICING YOUR GENERATOR 56 THE IMPORTANCE OF MAINTENANCE 56 MAINTENANCE SAFETY 57 Safety Precautions 57 MAINTENANCE SCHEDULE 58 ENGINE OIL CHANGE 59 AIR CLEANER SERVICE 60 Main and Outer Filters Cleaning 60 SPARK PLUG SERVICE 61 SPARK ARRESTER...

Page 7: ...HNICAL INFORMATION 75 SERIAL NUMBER LOCATION 75 CARBURETOR MODIFICATION FOR HIGH ALTITUDE OPERATION 76 EMISSION CONTROL SYSTEM INFORMATION 77 AIR INDEX 79 SPECIFICATIONS 80 WIRING DIAGRAM 82 CONSUMER INFORMATION 83 DEALER LOCATOR INFORMATION 83 Honda PUBLICATIONS 83 CUSTOMER SERVICE INFORMATION 84 Distributor s Limited Warranty 85 Emission Control System Warranty 90 REGISTRATION 95 Please Register...

Page 8: ... below along with the best way to protect yourself and others Operator Responsibility Never attempt to modify the generator It can cause an accident as well as damage to the generator and appliances Know how to stop the generator quickly in case of emergency Understand the use of all generator controls output receptacles and connections Be sure that anyone who operates the generator receives prope...

Page 9: ...ude headache fatigue shortness of breath nausea and dizziness Continued exposure to carbon monoxide can cause loss of muscular coordination loss of consciousness and then death To alert you to potentially dangerous levels of carbon monoxide coming from a generator operating outside or from other sources install battery operated carbon monoxide alarms or plug in carbon monoxide alarms with battery ...

Page 10: ...o not connect to a building s electrical system unless an isolation switch has been installed by a qualified electrician For parallel operation use only a Honda approved parallel operation cable kit optional equipment when connecting the generator combinations shown below An EU2200i can only be paired with EU2000i or EU2000i Companion models that have serial numbers within the ranges shown below N...

Page 11: ...eration and remains hot for a while after stopping the engine Be careful not to touch the muffler while it is hot Let the engine cool before storing the generator Do not pour the water directly on the generator to put out the fire when it occurs Use an appropriate fire extinguisher specially designed for electric fire or oil fire Refuel With Care Gasoline is highly flammable and gasoline vapor can...

Page 12: ...le trailer or boat Do not operate the generator when it is in a storage cargo or security enclosure including any RV generator bay Always completely remove the generator from the vehicle RV truck trailer boat other equipment or structure during operation The generator must remain stationary while in operation 31Z446100 book 10 ページ 2020年2月17日 月曜日 午前11時41分 ...

Page 13: ...hese labels warn you of potential hazards that can cause serious injury Read them carefully If a label comes off or becomes hard to read contact your servicing dealer for a replacement Example AG type 31Z446100 book 11 ページ 2020年2月17日 月曜日 午前11時41分 ...

Page 14: ...GENERATOR SAFETY 12 Example AG type 31Z446100 book 12 ページ 2020年2月17日 月曜日 午前11時41分 ...

Page 15: ...PI service category SJ or later or equivalent is recommended for general use for additional recommendations see page 14 Maximum oil capacity 14 oz 0 44 L Do not overfill the engine with oil If the engine is overfilled the excess oil may be transferred to the air cleaner housing and air filter 5 Screw in the oil filler cap securely 6 Reinstall the maintenance cover and tighten the maintenance cover...

Page 16: ...ended for general use Other viscosities shown in the chart may be used when the average temperature in your area is within the recommended range The SAE oil viscosity and service category are in the API label on the oil container Honda recommends that you use API service category SJ or later or equivalent oil AMBIENT TEMPERATURE 31Z446100 book 14 ページ 2020年2月17日 月曜日 午前11時41分 ...

Page 17: ...uel level is low wait for the generator to cool off and refill the fuel tank This engine is certified to operate on unleaded gasoline with a pump octane rating 86 or higher Refer to FUEL RECOMMENDATIONS see page 18 for additional fuel recommendations Fuel can damage paint and plastic Be careful not to spill fuel when filling your fuel tank Damage caused by spilled fuel is not covered under the Dis...

Page 18: ...e the upper level mark red on the fuel strainer Fuel can damage paint and plastic Be careful not to spill fuel when filling your fuel tank Damage caused by spilled fuel is not covered under the Distributor s Limited Warranty FUEL FILLER CAP UPPER LEVEL MARK RED TETHER FUEL STRAINER 31Z446100 book 16 ページ 2020年2月17日 月曜日 午前11時41分 ...

Page 19: ...rs away from the fueling source and site before starting the engine After initial fueling or anytime the generator is run completely out of fuel starting the engine may require additional pulls of the starter grip This generator utilizes a vacuum operated fuel pump and may require additional pulls to draw fuel into the carburetor FUEL FILLER CAP VENT LEVER OFF ON FUEL FILLER CAP 31Z446100 book 17 ...

Page 20: ...on inhibitors Use of fuels with content of ethanol or methanol greater than shown above may cause starting and or performance problems It may also damage metal rubber and plastic parts of the fuel system Engine damage or performance problems that result from using a fuel with percentages of ethanol or methanol greater than shown above and leaded gasoline are not covered under the Distributor Limit...

Page 21: ...es to locate and identify the most frequently used controls SPARK PLUG MAINTENANCE COVER MUFFLER SPARK PLUG FRAME SERIAL NUMBER AIR CLEANER FUEL FILLER CAP VENT LEVER FUEL FILLER CAP ENGINE SWITCH STARTER GRIP MAINTENANCE COVER CHOKE LEVER 31Z446100 book 19 ページ 2020年2月17日 月曜日 午前11時41分 ...

Page 22: ...OTTLE SWITCH PARALLEL OPERATION OUTLETS AC RECEPTACLES GROUND TERMINAL OUTPUT INDICATOR OVERLOAD ALARM INDICATOR OIL ALERT CHECK INDICATOR AC CIRCUIT PROTECTOR CO MINDER 20 A RECEPTACLE 30 A twist lock receptacle GROUND TERMINAL PARALLEL OPERATION OUTLETS ECO THROTTLE SWITCH OUTPUT INDICATOR OVERLOAD ALARM INDICATOR OIL ALERT CHECK INDICATOR AC CIRCUIT PROTECTORS CO MINDER 31Z446100 book 20 ページ 20...

Page 23: ...oses only the fuel valve see page 42 ON Running position opens the fuel valve and allows the engine to be started Starter Grip Pulling the starter grip operates the recoil starter to start the engine Do not allow the starter grip to snap back against the generator Return it gently to prevent damage to the starter ENGINE SWITCH ON OFF STARTER GRIP FUEL OFF 31Z446100 book 21 ページ 2020年2月17日 月曜日 午前11時...

Page 24: ...e possibility of fuel leakage Allow the engine to cool well before turning the vent lever to the OFF position Choke Lever The choke is used to provide proper starting mixture when the engine is cold It can be opened and closed by operating the choke lever manually Move the choke lever to the CLOSED position to enrich the mixture for cold starting FUEL FILLER CAP VENT LEVER OFF ON FUEL FILLER CAP O...

Page 25: ...oper speed to power the electrical load If high electrical loads are connected simultaneously turn the Eco Throttle switch to the OFF position to reduce voltage changes ON Recommended to minimize fuel consumption and further reduce noise levels when less than a full load is applied to the generator OFF The Eco Throttle system does not operate ECO THROTTLE SWITCH OFF ON 31Z446100 book 23 ページ 2020年2...

Page 26: ...e engine is stopped by the CO MINDER system change the operating location of the generator Do not operate the generator in an enclosed or partly enclosed area such as a garage Do not enclose or cover the generator with boards or a tent even when it is outside and away from of a building Place the generator so that the muffler is pointed in the same direction as the wind is blowing and the exhaust ...

Page 27: ...tion If this occurs do not attempt to restart the generator more than two times If the CO MINDER system is malfunctioning it cannot warn you of potential high concentrations of carbon monoxide Move the generator to a well ventilated location and consult an authorized Honda Power Equipment dealer CO SENSOR LIFE If the FAULT CO SENSOR LIFE indicator flashes when operating the generator the CO MINDER...

Page 28: ...mpanion or EU2000i generators Standard and Companion for parallel operation see page 48 through 52 A Honda approved parallel operation cable kit optional equipment is required for parallel operation This kit can be purchased from an authorized Honda generator dealer PARALLEL OPERATION OUTLETS 31Z446100 book 26 ページ 2020年2月17日 月曜日 午前11時41分 ...

Page 29: ...circuit protector switches OFF automatically check that the appliance is working properly and does not exceed the rated load capacity of the circuit before resetting the circuit protector ON AG AG3 types AG1 type 20 A RECEPTACLES ON OFF PUSH AC CIRCUIT PROTECTOR AC CIRCUIT PROTECTOR 20 A RECEPTACLES ON OFF PUSH AC CIRCUIT PROTECTOR AC CIRCUIT PROTECTOR 31Z446100 book 27 ページ 2020年2月17日 月曜日 午前11時41分...

Page 30: ...ualified electrician electrical inspector or local agency having jurisdiction for local codes or ordinances that apply to the intended use of the generator NEUTRAL FLOATING The generator stator winding is isolated from the frame and from the AC receptacle ground pin Electrical devices that require a grounded receptacle pin connection will not function if the receptacle ground pin is not functional...

Page 31: ...acles In addition the output indicator has a simplified hour meter function When you start the engine the indicator blinks according to the generator s cumulative operating hours as follows No blinks 0 100 hours 1 blink 100 200 hours 2 blinks 200 300 hours 3 blinks 300 400 hours 4 blinks 400 500 hours 5 blinks 500 or more hours OUTPUT INDICATOR GREEN 31Z446100 book 29 ページ 2020年2月17日 月曜日 午前11時41分 ...

Page 32: ...Check Indicator The Oil Alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase Before the oil level in the crankcase can fall below a safe limit the Oil Alert Check indicator red comes ON and the Oil Alert system automatically will stop the engine the engine switch will remain in the ON position If the engine stops or the Oil Alert Check indicato...

Page 33: ...tatus Possible cause Output Indicator Overload Alarm Indicator Oil Alert Check Indicator Normal Operating normally Malfunction Inverter unit failure Abnormal Output overcurrent Inverter unit overheat Warning Engine oil low OIL ALERT CHECK INDICATOR OVERLOAD ALARM INDICATOR OUTPUT INDICATOR 31Z446100 book 31 ページ 2020年2月17日 月曜日 午前11時41分 ...

Page 34: ...ator engine from a distance Remote monitoring Displays power output level Receive notifications Can receive error and maintenance alerts Downloading the app Go to the App Store iOS or Google Play Android and search for Honda My Generator to download the app Pairing For first time connection only Refer to the Support on the Honda My Generator smartphone application to pair the smartphone with the g...

Page 35: ...ting see pages 47 and 52 IS YOUR GENERATOR READY TO GO For your safety to ensure compliance with environmental regulations and to maximize the service life of your equipment it is very important to take a few moments before you operate the generator to check its condition Be sure to take care of any problem you find or have your servicing dealer correct it before you operate the generator Failure ...

Page 36: ...ilters will restrict air flow to the fuel system reducing engine and generator performance Check the fuel level see page 15 Starting with a full tank will help to eliminate or reduce operating interruptions for refueling AC Appliance and Power Cord Before connecting an AC appliance or power cord to the generator Use grounded 3 prong extension cords tools and appliances or double insulated tools an...

Page 37: ...low the lower limit fill with the recommended oil to the upper limit Do not overfill Upper limit means the oil exists to the oil filler neck Lower limit means the oil is attached only to the lower end of the dipstick Refer to ENGINE OIL RECOMMENDATIONS in page 14 5 Reinstall the oil filler cap securely 6 Reinstall the maintenance cover and tighten the maintenance cover screw securely MAINTENANCE C...

Page 38: ... Loosen the air cleaner cover screw and remove the air cleaner cover 3 Remove the main and outer filters from the air cleaner housing 4 Check the main and outer filters to be sure they are clean and in good condition If the main and outer filters are dirty clean them as described on page 60 Replace the main and outer filters if they are damaged MAIN FILTER MAINTENANCE COVER SCREW MAINTENANCE COVER...

Page 39: ...ll the maintenance cover and tighten the maintenance cover screw securely Operating the engine without the air filters or with a damaged air filter will allow dirt to enter the engine causing rapid engine wear This type of damage is not covered by the Distributor s Limited Warranty AIR CLEANER COVER RUBBER SEAL AIR FILTERS AIR CLEANER COVER SCREW AIR CLEANER COVER 31Z446100 book 37 ページ 2020年2月17日 ...

Page 40: ...ailers or boats Do not operate the generator when it is in a storage cargo or security enclosure including any RV generator bay Always completely remove the generator from the vehicle trailer boat or other equipment or structure during operation The generator must remain stationary while in operation Exhaust contains poisonous carbon monoxide gas that can build up to dangerous levels in enclosed o...

Page 41: ...ud water etc Cooling holes are located on the side panel the control panel and the bottom of the generator If the cooling holes are blocked the generator may overheat and damage the engine inverter or windings Since the CO MINDER may detect the carbon monoxide concentration and the engine may stop automatically pay attention to the direction of exhaust and where the generator is located see page 2...

Page 42: ...ed for warm up 4 To start a cold engine move the choke lever to the CLOSED position To restart a warm engine leave the choke lever in the OPEN position 5 Turn the engine switch to the ON position ECO THROTTLE SWITCH CHOKE LEVER CLOSED ON ENGINE SWITCH OFF 31Z446100 book 40 ページ 2020年2月17日 月曜日 午前11時41分 ...

Page 43: ...nt damage to the starter 7 If the choke lever was moved to the CLOSED position to start the engine gradually move it to the OPEN position as the engine warms up 8 If you wish to use the Eco Throttle system turn the Eco Throttle switch to the ON position after the engine has warmed up for 2 or 3 minutes STARTER GRIP CHOKE LEVER ECO THROTTLE SWITCH OPEN Direction to pull ON 31Z446100 book 41 ページ 202...

Page 44: ...osition can reduce the fuel in the carburetor When using the FUEL OFF position the generator will continue to run for several minutes until the fuel in the carburetor has been consumed and then the engine will stop Turn the engine switch to the OFF position after the engine stops After stopping the engine using the FUEL OFF position restarting the engine will require additional pulls on the recoil...

Page 45: ...ng period of time refer to page 67 for information on DRAINING THE FUEL TANK AND CARBURETOR STOPPING THE ENGINE with Bluetooth ENABLED SMARTPHONE The engine can be stopped via a Bluetooth enabled smartphone using a Bluetooth application Refer to the Bluetooth application to check the connection operation and for help pairing a smartphone PARALLEL OPERATION CABLE optional equipment 31Z446100 book 4...

Page 46: ...tandard procedure for starting the engine When the CO ALARM indicator or the FAULT CO MINDER LIFE indicator flashes press the CO MINDER reset button to turn off the indicator After the engine is stopped by the CO MINDER CO Shut off System the engine cannot be restarted for approximately 30 seconds The Oil Alert Check Indicator also comes ON when the engine is automatically stopped by the CO MINDER...

Page 47: ...cal rating for startup When an electric motor is started the overload alarm indicator red may come ON This is normal if the overload alarm indicator red goes OFF within 4 seconds If the overload alarm indicator red stays ON consult your Honda Power Equipment dealer 1 Start the engine see page 39 and make sure the output indicator green comes ON OVERLOAD ALARM INDICATOR RED OUTPUT INDICATOR GREEN 3...

Page 48: ...ed will go ON The overload alarm indicator red will stay ON and after about four seconds current to the connected appliance s will shut off and the output indicator green will go OFF Stop the engine and investigate the problem Determine if the cause is a short circuit in a connected appliance or an overload Correct the problem and restart the generator 20 A RECEPTACLE 31Z446100 book 46 ページ 2020年2月...

Page 49: ...e for startup Make sure the electrical rating of the tool or appliance does not exceed the maximum power rating of the generator Maximum power is 2 2 kVA For continuous operation do not exceed the rated power Rated power is 1 8 kVA In either case the total power requirements VA of all appliances connected must be considered Appliance and power tool manufacturers usually list rating information nea...

Page 50: ...e overload alarm indicator red may come ON This is normal if the overload alarm indicator red goes OFF within 4 seconds If the overload alarm indicator red stays ON consult an authorized Honda Power Equipment dealer During parallel operation the Eco Throttle switch should be in the same position on both generators 1 Connect the parallel operation cable between the EU2200i to either an EU2200i Comp...

Page 51: ...ded see page 52 or if there is a short circuit in a connected appliance the overload alarm indicator red will go ON The overload alarm indicator red will stay ON and after about four seconds current to the connected appliance s will shut off and the output indicator green will go OFF Stop both engines and investigate the problem Determine if the cause is a short circuit in a connected appliance or...

Page 52: ...A faulty appliance or power cord can create a potential for electrical shock If an appliance begins to operate abnormally becomes sluggish or stops suddenly turn it off immediately Disconnect the appliance and determine whether the problem is the appliance or the rated load capacity of the generator has been exceeded Never connect other than the specified generator models see page 8 For parallel o...

Page 53: ...gn the two generators so that their mufflers are on the same line and exhaust in the same direction Place the generator so that the muffler is pointed in the same direction as the wind is blowing and the exhaust is directed away from buildings other structures or vehicles EXHAUST EXHAUST ON THE SAME LINE WIND DIRECTION WIND DIRECTION This generator may detect exhaust from the adjacent generator an...

Page 54: ...d Appliance and power tool manufacturers usually list rating information near the model number or serial number Substantial overloading that continuously lights the overload alarm indicator red may damage the generator Marginal overloading that temporarily lights the overload alarm indicator red may shorten the service life of the generator EU2200i EU2200i Companion and EU2200i Companion 4 4kVA EU...

Page 55: ...enerator Turn the Eco Throttle switch to the OFF position and connect the appliance to the generator If the engine still will not reach normal operating speed check that the appliance does not exceed the rated load capacity of the generator If high electrical loads are connected simultaneously turn the Eco Throttle switch to the OFF position to reduce voltage changes The Eco Throttle system is not...

Page 56: ...edures System Ground This generator has a system ground that connects generator frame components to ground terminals in the AC output receptacles The system ground is not connected to the AC neutral wire Improper connections to a building s electrical system can allow current from the generator to backfeed into the utility lines Such backfeed may electrocute utility company workers or others who c...

Page 57: ...istration OSHA regulations local codes or ordinances that apply to the intended use of the generator Please consult a qualified electrician electrical inspector or the local agency having jurisdiction In some areas generators are required to be registered with local utility companies If the generator is used at a construction site there may be additional regulations that must be observed 31Z446100...

Page 58: ...ation or use it in dusty conditions consult your servicing dealer for recommendations applicable to your individual needs and use Remember that an authorized Honda Power Equipment dealer knows your generator best and is fully equipped to maintain and repair it To ensure the best quality and reliability use only new Honda Genuine parts or their equivalents for repair and replacement Maintenance rep...

Page 59: ...Operate outside away from open windows or doors with engine exhaust directed away from occupied structures Burns from hot parts Let the engine and exhaust system cool before touching Injury from moving parts Do not run the engine unless instructed to do so To reduce the possibility of fire or explosion be careful when working around gasoline Use only a non flammable solvent not gasoline to clean p...

Page 60: ... log hours of operation to determine proper maintenance intervals REGULAR SERVICE PERIOD 3 Perform at every indicated month or operating hour interval whichever comes first ITEM Each use First month or 20 Hrs Every 3 months or 50 Hrs Every 6 months or 100 Hrs Every year or 200 Hrs Page Engine oil Check level o 35 Change o o 59 Air cleaner Check o 36 Clean o 1 60 Spark plug Check adjust o 61 Replac...

Page 61: ...environment If you change your own oil please dispose of the used oil properly Put it in a sealed container and take it to a recycling center Do not discard it in a trash bin dump it on the ground or pour it down the drain 5 With the generator in a level position fill with the recommended oil to the upper limit Do not overfill Upper limit means the oil exists to the oil filler neck Refer to ENGINE...

Page 62: ... in warm soapy water rinse and allow to dry thoroughly or clean in nonflammable solvent and allow to dry 2 Dip the air cleaner element in clean engine oil and then squeeze out all excess oil The engine will smoke when started if too much oil is left in the air filters 3 Wipe dirt from the air cleaner housing and cover using a moist rag Be careful to prevent dirt from entering the air duct that lea...

Page 63: ...ped and free of deposits An incorrect spark plug can cause engine damage If the engine is hot allow it to cool before servicing the spark plug 1 Remove the spark plug maintenance cover 2 Disconnect the spark plug cap and remove any dirt from around the spark plug area 3 Remove the spark plug with a spark plug wrench SPARK PLUG MAINTENANCE COVER SPARK PLUG CAP SPARK PLUG WRENCH SPARK PLUG CAP 31Z44...

Page 64: ...plug in by hand to prevent cross threading 7 After the spark plug is seated tighten with a spark plug wrench to compress the washer If reinstalling a used spark plug tighten 1 8 1 4 turn after the spark plug is seated If installing a new spark plug tighten 1 2 turn after the spark plug is seated Torque 8 7 lbf ft 12 N m 1 2 kgf m A loose spark plug can overheat and damage the engine Overtightening...

Page 65: ...y hot Allow the muffler to cool before servicing the spark arrester Clean the spark arrester as follows 1 Remove the four 6 mm screws and remove the muffler protector 2 Remove the three 6 mm bolts and remove the muffler the spark arrester and the muffler gasket MUFFLER PROTECTOR 6 mm SCREWS MUFFLER GASKET Replace SPARK ARRESTER MUFFLER 6 mm BOLTS 31Z446100 book 63 ページ 2020年2月17日 月曜日 午前11時41分 ...

Page 66: ...Be careful to avoid damaging the screen The spark arrester must be free of breaks and tears Replace the spark arrester if it is damaged 4 Replace a new muffler gasket the spark arrester the muffler and the muffler protector in the reverse order of removal 31Z446100 book 64 ページ 2020年2月17日 月曜日 午前11時41分 ...

Page 67: ...d it leaves gum deposits that clog the fuel system If the gasoline in your generator deteriorates during storage you may need to have the carburetor and other fuel system components serviced or replaced The length of time that gasoline can be left in your fuel tank and carburetor without causing functional problems will vary with such factors as gasoline blend your storage temperatures and whether...

Page 68: ...gasoline stabilizer Turn the engine switch to the OFF position and drain the carburetor float bowl see page 68 1 year or more Drain the fuel tank and carburetor see page 67 Change the engine oil and lubricate the cylinder see page 69 Use gasoline stabilizers that are formulated to extend storage life Follow the manufacturer s instructions for use Contact your authorized Honda Power Equipment deale...

Page 69: ...to empty the tank Do not use an electric pump Reinstall the fuel strainer and the fuel filler cap Gasoline is highly flammable and explosive You can be burned or seriously injured when handling fuel Stop the engine and let it cool before handling fuel Keep heat sparks and flame away Handle fuel only outdoors Keep away from your vehicle Wipe up spills immediately FUEL STRAINER FUEL FILLER CAP 31Z44...

Page 70: ... suitable container 4 Remove the spark plug maintenance cover and the spark plug cap see page 61 5 Turn the engine switch to the ON position see page 40 6 Pull the starter grip 3 to 4 times to drain the gasoline from the fuel pump into a suitable container MAINTENANCE COVER SCREW MAINTENANCE COVER CARBURETOR DRAIN SCREW 31Z446100 book 68 ページ 2020年2月17日 月曜日 午前11時41分 ...

Page 71: ... cc of clean engine oil into the cylinder Crank the engine several revolutions to distribute the oil then reinstall the spark plug 2 Reinstall the spark plug cap on the spark plug securely 3 Reinstall the spark plug maintenance cover 4 Reinstall the maintenance cover and tighten the maintenance cover screw securely 5 Pull the starter grip see page 41 slowly until you feel resistance then return th...

Page 72: ...lace the generator on a level surface Tilting or laying it on its side can cause fuel or oil leakage With the engine and exhaust system cool cover the generator to keep out dust A hot engine and exhaust system can ignite or melt some materials Do not use a plastic sheet as a dust cover A nonporous cover will trap moisture around the generator promoting rust and corrosion REMOVAL FROM STORAGE Check...

Page 73: ...or your property Do not operate the generator while it is being transported or while it is mounted to any type of vehicle trailer or boat Take care not to drop or strike the generator when transporting Do not place heavy objects on the generator An engine that has been running will remain very hot for a period of time A hot engine and exhaust system can burn you and ignite some material If the gen...

Page 74: ...engine oil Then turn the engine switch to the ON position and restart the engine Spark plug faulty fouled or improperly gapped Gap or replace spark plug see page 61 Spark plug wet with fuel flooded engine Dry and reinstall spark plug Fuel strainer restricted carburetor malfunction ignition malfunction valves stuck etc Take the generator to an authorized Honda Power Equipment dealer or refer to the...

Page 75: ...uipment dealer or refer to the shop manual Possible Cause Correction Output indicator is OFF and overload alarm indicator is ON Check AC load Stop and restart the engine Check the cooling air inlet Stop and restart the engine Overload alarm indicator blink Take the generator to an authorized Honda Power Equipment dealer or refer to the shop manual AC circuit protector tripped Check AC load and res...

Page 76: ...y CO MINDER press the CO MINDER reset button to restart the engine see page 44 Possible Cause Correction CO sensor malfunction If the engine cannot be started and the CO ALARM indicator flashes even if the location of the generator has changed there may be a CO MINDER malfunction Consult an authorized Honda Power Equipment dealer CO sensor may have reached the end of its useful lifespan see page 2...

Page 77: ... serial number Date purchased Entering the frame serial number of the generator is required during the first Bluetooth connection Read the QR code or enter the 12 digit frame serial number contained hyphen Record the password set for the Bluetooth connection in the space below Do not write or attach the password on the generator Bluetooth password FRAME SERIAL NUMBER QR CODE 31Z446100 book 75 ページ ...

Page 78: ...his carburetor modification This engine when operated at high altitude with the carburetor modifications for high altitude use will meet each emission standard throughout its useful life Even with carburetor modification engine horsepower will decrease about 3 5 for each 1 000 foot 300 meter increase in altitude The effect of altitude on horsepower will be greater than this if no carburetor modifi...

Page 79: ...reduce evaporative emissions The U S and California Clean Air Acts EPA and California regulations require all manufacturers to furnish written instructions describing the operation and maintenance of emission control systems The following instructions and procedures must be followed in order to keep the Honda engine emissions within the emission standards Tampering and Altering Tampering is a viol...

Page 80: ...have service performed at non Honda locations However the use of replacement parts that are not of the original design and quality may impair the effectiveness of your emissions control system A manufacturer of an aftermarket part assumes the responsibility that the part will not adversely affect emissions performance The manufacturer or rebuilder of the part must certify that use of the part will...

Page 81: ...bility description is intended to provide you with information relating to the engine s emission durability period The descriptive term indicates the useful life period for the engine s emission control system See your Emission Control System Warranty see page 90 for additional information Descriptive Term Applicable to Emission Durability Period Moderate 50 hours 0 80 cc inclusive 125 hours great...

Page 82: ...nt Bore Stroke 7 38 cu in 121 cm3 2 36 1 69 in 60 0 43 0 mm Compression ratio 8 5 1 Engine speed 4 000 4 500 rpm with Eco Throttle switch OFF Cooling system Forced air Ignition system Full transistor Engine oil capacity 14 oz 0 44 L Fuel tank capacity 0 95 US gal 3 6 L Spark plug CR5HSB NGK Model EU2200iT EU2200iTCompanion Type AG AG3 AG1 AC output Rated voltage 120 V Rated frequency 60 Hz Rated c...

Page 83: ... without notice ITEM SPECIFICATION MAINTENANCE Spark plug gap 0 024 0 028 in 0 6 0 7 mm Refer to page 61 Valve clearance cold IN 0 15 0 04 mm EX 0 20 0 04 mm See your authorized Honda dealer Other specifications No other adjustments needed 31Z446100 book 81 ページ 2020年2月17日 月曜日 午前11時41分 ...

Page 84: ...X PC N C 10 12V 6 GND 7 CO 1 EARTH 1 STOP 2 STOP 3 EARTH 4 EARTH 5 POWER_SUPPLY 11 POWER_SUPPLY 6 N C 10 N C 14 N C 16 N C 20 N C 22 N C 23 N C 24 N C 21 VOUT 19 RELAY 18 N C 17 TEST 15 ING 12 N C 13 RESET 8 N C 9 IND2_TROUBLE 7 IND1_CO 2 IND_CO 3 IND_TROUBLE 4 TEST_SW 5 RESET_SW AC RECEPTACLE NOISE FILTER ECO THROTTLE SW PARALLEL 1 PARALLEL 2 BLUETOOTH UNIT INVERTER UNIT MAIN W EX W SUB W FRM EAR...

Page 85: ...upport shop manuals Parts Catalog This manual provides complete illustrated parts lists for your generator Visit peparts honda com for free online access to the parts catalog It is also available for purchase in paper form through your Honda dealer Accessories Catalog Your authorized Honda Power Equipment dealer offers a wide selection of accessories optional equipment to make your generator even ...

Page 86: ...by the dealership s management contact the Honda Power Equipment Customer Relations Office You can write to American Honda Motor Co Inc Power Equipment Division Customer Relations Office 4900 Marconi Drive Alpharetta Georgia 30005 8847 Or telephone 770 497 6400 1 888 888 3139 toll free 8 30 am to 7 00 pm ET When you write or call please give us this information Model and serial numbers see page 75...

Page 87: ...rican Honda or a dealer authorized by American Honda to sell those products This warranty applies to first retail purchaser and each subsequent owner during the applicable warranty time period unless noted otherwise What American Honda will Repair or Replace Under Warranty American Honda will repair or replace at its option any part that is proven to be defective in material or workmanship under n...

Page 88: ...To locate a dealer near you visit our web site at http powerequipment honda com and click on Find a Dealer If you are unable to obtain warranty service or are dissatisfied with the warranty service you receive contact the owner of the dealership involved normally this will resolve the problem However if you should require further assistance write or call the Power Equipment Customer Relations Depa...

Page 89: ...h disc tire wheel bearing recoil starter rope cable belt cutter blade oil and grease 3 Cleaning adjustment and normal periodic maintenance work carburetor cleaning engine oil draining blade sharpening belt and cable adjustments 4 Any product that has ever been declared a total loss or sold for salvage by a financial institution or insurer 5 Auger and paddle assemblies skid shoes and scraper bars o...

Page 90: ...nt parts accessories or apparel that are proven to be defective in material or workmanship under normal use during the applicable warranty time period Anything replaced under warranty becomes the property of American Honda Motor Co Inc The warranty on all parts accessories and apparel replaced under warranty will expire coincident with the original warranty on the replaced parts accessories or app...

Page 91: ...pparel affected or damaged by collision normal wear use in an application for which the product was not designed or any other misuse neglect incorporation or use of unsuitable attachments or parts unauthorized alteration improper installation or any causes other than defects in material or workmanship of the product Installing parts and accessories on non Honda products or engines voids this warra...

Page 92: ...quipped to meet the State s stringent anti smog standards Honda must warrant the emissions control system on your power equipment engine for the periods of time listed below provided there has been no abuse neglect or improper maintenance of your small off road engine or equipment leading to the failure of the emissions control system Your emissions control system may include parts such as the car...

Page 93: ...art has failed due to abuse neglect improper maintenance or unapproved modifications You are responsible for presenting your power equipment engine to a Honda Power Equipment servicing dealer as soon as the problem exists The warranty repairs shall be completed in a reasonable amount of time not to exceed 30 days If you have any questions regarding your warranty rights and responsibilities you sho...

Page 94: ...y Honda approved replacement parts may be used in the performance of any warranty repairs and must be provided without charge to the owner A list of warranted parts is on the reverse side of this warranty statement All emission related parts are under warranty for the remainder of the warranty period Normal maintenance items such as spark plugs and filters that are on the warranted parts list are ...

Page 95: ...u require further assistance contact the Honda office in your region EXCLUSIONS Failures other than those resulting from defects in material or workmanship are not covered by this warranty This warranty does not extend to emission control systems or parts that are affected or damaged by owner abuse neglect improper maintenance or unapproved modifications This warranty does not cover replacement of...

Page 96: ...uel Metering Carburetor assembly includes starting enrichment system Oxygen sensor Throttle body Engine temperature sensor Engine control module Fuel injector Fuel regulator Intake manifold Evaporative Fuel tank Fuel cap Fuel lines for liquid and fuel vapors Carbon canister Canister mounting brackets Fuel line fittings Fuel strainer Fuel valve Fuel pump Fuel hose joint Canister purge port connecto...

Page 97: ...tact you with any important updates regarding your generator Please note registration is not required to obtain warranty service You can register your generator by visiting the Honda Power Equipment website http powerequipment honda com and selecting Product Registration Your information will remain confidential It will not be released to any other company or organization 31Z446100 book 95 ページ 202...

Page 98: ...tooth unit included with this equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the in...

Page 99: ...ATION FOR HIGH ALTITUDE OPERATION 76 Check the Engine 34 Choke Lever 22 Cleaning 65 CO MINDER CO Shut off System 24 COMPONENT CONTROL LOCATIONS 19 Connections to a Building s Electrical System 54 CONSUMER INFORMATION 83 CONTROLS FEATURES 19 CONTROLS 21 CUSTOMER SERVICE INFORMATION 84 D DEALER LOCATOR INFORMATION 83 Distributor s Limited Warranty 85 E Eco Throttle Switch 23 ECO THROTTLE SYSTEM 53 E...

Page 100: ...tch 21 ENGINE WILL NOT START 72 F FAULT CO SENSOR LIFE INDICATOR FLASHING WHEN RUNNING THE ENGINE 74 FEATURES 28 Fire and Burn Hazards 9 Fuel Filler Cap Vent Lever 22 FUEL RECOMMENDATIONS 18 FUEL 15 65 G GENERATOR SAFETY 6 Ground Terminal 28 H Honda PUBLICATIONS 83 HOW TO RESTART WHEN STOPPED BY CO MINDER CO SHUT OFF SYSTEM 44 I IMPORTANT SAFETY INFORMATION 6 INITIAL USE INSTRUCTIONS 13 INTRODUCTI...

Page 101: ...el Operation Outlets 26 Parallel operation with EU2000i 50 Please Register Your Generator 95 Q QUICK REFERENCE INFORMATION inside back cover R REFERENCE INFORMATION 96 Refuel With Care 9 REGISTRATION 95 REMOVAL FROM STORAGE 70 S SAFE OPERATING PRECAUTIONS 38 SAFETY LABEL LOCATIONS 11 Safety Precautions 57 SERIAL NUMBER LOCATION 75 SERVICING YOUR GENERATOR 56 Smartphone application 32 SPARK ARRESTE...

Page 102: ...h ENABLED SMARTPHONE 43 STOPPING THE ENGINE 42 STORAGE PRECAUTIONS 70 STORAGE PREPARATION 65 STORAGE 65 System Ground 54 T TAKING CARE OF UNEXPECTED PROBLEMS 72 TECHNICAL INFORMATION 75 THE IMPORTANCE OF MAINTENANCE 56 TRANSPORTING 71 V Vehicles and Transportation Hazards 10 W WIRING DIAGRAM 82 31Z446100 book 100 ページ 2020年2月17日 月曜日 午前11時41分 ...

Page 103: ... Type SAE 10W 30 API SJ or later or equivalent for general use see page 14 Maximum oil capacity 14 oz 0 44 L Spark Plug Type NGK CR5HSB Electrode Gap 0 024 0 028 in 0 6 0 7 mm Maintenance Before each use Check engine oil level Check air filter First 20 hours Change engine oil Subsequent See MAINTENANCE SCHEDULE see page 58 31Z446100 book 101 ページ 2020年2月17日 月曜日 午前11時41分 ...

Page 104: ...hailand 31Z44610 00X31 Z44 6100 GENERATOR Owner s Manual H i FM AH 英 PANTONE 186C K 背幅4 6mm EU2200i EU2200i Companion Companion See page 13 for Initial Use Instructions 2020 Honda Motor Co Ltd All Rights Reserved C ...

Reviews: