background image

760A 

OPERATION MANUAL

 

3 1/2 DIGITAL 

MULTIMETER

 

 

 
1

 

INTRODUCTION 

This instrument is a compact 

battery operated

handheld 

3  1/2  digital  multimeter  designed  for  use    by    technicians

servicemen

  students

  and  hobbyists  who  required  an 

instrument that is accurate

  reliable 

and always ready for use. 

The  Dual-slope-A/D  converter  uses  C-MOS  technology  for 
auto-zeroing 

polarity selection and over-range indication. Full 

overload protection is provided. It is powered by a standard 9V 
transistor  radio  type  battery  .please  read  this  manual  that 
describes various useful message before using the multimeter. 

2

 Panel Layout 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1

LCD Display: 3½  digits, LCD digit height 27mm 

2

POWER Switch

Boot Up / Shutdown

 

3

Data-hold Switch (HOLD)

Pressing this button, the meter enters 

the auto data hold mode and “HOLD” is displayed on the LCD. 
4

Back Light/ Function switch indicator lamp key: Pressing the 

button turns the backlight and the function switch indicator lamp 
on

pressing it again turns them off. 

5

Function switch indicator lamp 

6) hFE Input Jack

 

7) Rotary Switch: use this switch to select functions and ranges 
8)

 

mechanical blocking 

system.

 

9

V  ΩInput  Jack

20A    Input  Jack

mA  Input  Jack 

COM   

Input Jack

 

3

  SPECIFICATION

 

3.1 GENERAL CHARACTERISTICS 

3.1.1 3 1/2 digit big LCD max.    Indication 1999. 
3.1.2 Auto-Zero & Auto-Polarity. 
31.3 Over range: indication of 

“1” or “-1”. 

3.1.4 Low battery indication: 

“ ” 

3.1.5 Power supply: 9V Zinc-carbon battery. 
3.1.6  Safety  standards  :The  meter  is  up  to  the  standards  of 
IEC1010  Double  Insulation  ,  Pollution  Degree  2  ,over  voltage 
Category 

3.1.7  Mechanical  blocking  system  for  terminal  sockets  to 
prevent mistake operation 
3.1.8 Temperature for guaranteed accuracy: 23

℃±

5

 

3.1.9 Temperature range: 

Operating :0

  to 40 

  Storage : -20

  to 60 

 

3.1.10 Humidity range: 

Operating: max 75%RH Storage: max 80%RH 

3.1.11 Size: 190mm

×

88.5mm

×

27.5mm 

3.1.12 Weight: Approx 320g (including battery). 
31.13 Accessories: 

operation manual                            1 piece   
test leads                                          1 pair   
color gift box                                    1 piece 

3.2 MEASUREMENT SPECIFICATION 

Environment: 
Temperature : 23

℃±

5

    relative humidity : max .75% 

3.2.1 DC voltage   

Range 

Accuracy 

Resolution 

200mV 

±

(0.5% of rdg + 8digits) 

100uV 

2V 

1mV 

20V 

10mV 

200V 

100mV 

1000V 

±

(1.5% of rdg + 8 digits) 

1V 

Overload Protection : 1000V DC/700Vrms AC on other ranges. 
Input impedance : 10M

Ω

  on all ranges 

3.2.2  AC  voltage  (

Average  sensing.  calibrated  to  rms  of  sine 

wave)

 

Range 

Accuracy 

Resolution 

2V 

±

(1.5% of rdg + 10 digits) 

1mV 

20V 

10mV 

200V 

100mV 

700V 

±

(2.5% of rdg +10 digits) 

1V 

Frequency:2V~20V at 40Hz~400Hz; 700V at 40Hz~200Hz 
Overload Protection: 1000V DC/700Vrms AC on all ranges. 
Input impedance : 1M

Ω

  on 2V range; 10 M

Ω

  on other ranges. 

3.2.3 DC Current 

Range 

Accuracy 

Resolution 

2mA 

±

(0.8% of rdg +8 digits) 

1

μ

20mA 

10

μ

200mA 

±

(1.2% of rdg +8 digits) 

100

μ

20A 

±

(2.0% of rdg +10 digits) 

10mA 

Overload  Protection:0.2A/250V  fuse    20A/250  fuse  20A  up  to 
10 seconds   

3.2.4  AC  curren

t  (Average  sensing.  Calibrated  to  rms  of  sine 

wave) 

Range 

Accuracy 

Resolution 

2mA 

±

(1.0% of rdg + 8 digits) 

1

μ

200mA 

±

(2.0% of rdg + 8 digits) 

100

μ

20A 

±

(3.0% of rdg + 15 digits) 

10mA 

Frequency: 40~200Hz 
Overload protection: 0.2A /250V fuse,20A/250V fuse 20A up to 
10 seconds   

3.2.5 Resistance 

Range 

Accuracy 

Resolution 

200

Ω

 

±

(1.2% of rdg +15 digits) 

0.1

Ω

 

2k

Ω

 

±

(0.8% of rdg + 8 digits) 

1

Ω

 

20k

Ω

 

10

Ω

 

200k

Ω

 

100

Ω

 

2M

Ω

 

1k

Ω

 

20M

Ω

 

±

(2.5% of rdg + 15 digits) 

10k

Ω

 

200MΩ 

±【5.0% of (

rdg

 -10)+ 30

 digits

】 

100kΩ 

Overload protection:250V DC/250Vrms AC for all range.

 

3.2.6 Capacitance   

Range 

Accuracy 

Resolution 

2nF 

±

(2.5% of rdg + 25 digits) 

1pF 

20nF 

±

(2.5% of rdg + 20 digits) 

10pF 

200nF 

100pF 

2

μ

1nF 

20

μ

10nF 

Overload Protection :36V DC/36Vrms AC for all range   

3.2.7 Transistor hFE test   

Range 

Description 

Test Condition 

hFE 

Display read approx .hFE value 
(0~1000) of transistor under test   
(NPN and PNP Type )   

Bast 

Current 

approx  10

μ

Vce approx 3V 

3.2.8 Diode test and Audible Continuity Test 

Range 

Description 

Test Condition 

 

Display read approximately 

forward Voltage of diode. 

Forward DC current 

approx 1.5mA 

.Reversed DC 

voltage 

approximately 3V 

 

Built-in buzzer sounds if 
resistance is less than 80

Ω

Open circuit voltage 
approx 3V 

Overload protection: 250V DC/250Vrms AC. 

4. HOW TO USE THE MULTIMETER   

PRELIMINARY NOTE:   
1. If the battery is weak. a 

“ ” sign will appear on display. The 

battery should be replaced   

 

Reviews: