background image

     

                                                     

      

EQC-Counting Scale 

 

User Manual 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

User Manual 

EQC

 

Series 

Price Computing Scale   

Digital Counting Scale   

Summary of Contents for EQC Series

Page 1: ...EQC Counting Scale User Manual User Manual EQC Series Price Computing Scale Digital Counting Scale ...

Page 2: ...fter a long period of storage more than one month It takes 8 10 hours to fully recharge the battery Please assemble the platter before powering on the scale Do not keep the weight placed on the platter for a long period Keep the scale away from the environment with high temperature high humidity heavy press heavy bump Always make sure the scale is located in a flat and plane surface 1 ...

Page 3: ...EQC Counting Scale User Manual Dimensions EQC 2 ...

Page 4: ...tes the tare weight has been deducted Indication of kg g Weighing Mode Cursor flashes on the bottom edge of WEIGHT LCD above of kg or g printed on the display overlay and indicates the present weighing mode Insufficient Sampling Quantity Indication Cursor appears on the bottom edge of UNIT WEIGHT LCD above of S Q printed on the display overlay and indicates the sampling quantity setup via SAMPLE k...

Page 5: ...T LCD For example With 30kg max capacity and an internal resolution of 60000 30kg 60000 0 5g If the average unit weight of measured subjects is lighter than 0 5g cursor will flash on UNIT WEIGHT LCD above of S W printed on the display overlay Indication of Weighing Range Cursor appears on the bottom edge of UNIT PRICE LCD above of W1 or W2 printed on the display overlay and indicates the present w...

Page 6: ... is running in low voltage status WEIGHT LCD will indicate continuously for reminding the user to recharge the battery If the battery is still running in low voltage status without being recharged WEIGHT LCD will indicate OFF and the scale will sound beep for eight time Please power off the scale and recharge the battery right away 5 ...

Page 7: ...ng in low voltage status Please recharge the battery as soon as possible Pressing C key could go back to normal operating mode 1 Press this key to set the decimal point for the unit weight 2 Press and hold key till the scale sounds beep to enable or disable optional Backlight C Press this key to delete the setting values of unit weight ZERO Press this key to make the scale be at zero point WEIGHT ...

Page 8: ...uantity Example Put 500pcs of screws on the platter then key in 500 then press SAMPLE key once the scale will calculate the averaging unit weight of 500 screws and show the value on UNIT WEIGHT LCD While putting another more pieces less than 500pcs of screws on the platter the scale will re calculate the averaging unit weight UNIT WEIGHT LCD will clear the original value and then show the updated ...

Page 9: ...t weight at 10g please key in 10 then press WS once then 10g will be indicated on UNIT WEIGHT LCD ALARM 1 Quantity Alarm 1 Press ALARM key to select PCS showed on UNIT WEIGHT LCD 2 Key in 100 showed on WEIGHT LCD then press ALARM key again to confirm the setting Notice The setting values under Hi mode and Lo mode must be 0 When the total quantity of measured subjects is 100 the scale will sound be...

Page 10: ...to confirm the setting Notice The setting value under PCS mode must be 0 The scale will sound beep continuously while 9 500 the total weight value 10 500 3 Over Weight Alarm Example setup 10kg as the over weight limit Press ALARM key to select Lo showed on UNIT WEIGHT LCD then key in 10 000 showed on WEIGHT LCD then press ALARM key again to confirm the setting Notice The setting values under PCS m...

Page 11: ...rices Example Save 7 50 into M3 memory bank Key in 7 5 0 Press and hold M3 key till the scale sounds beep Finish setting At this moment pressing M3 key could recall 7 50 showed on UNIT PRICE LCD To modify the setting figure of M3 please just follow the above steps again 10 ...

Page 12: ...cale User Manual RS232 Interface Connection optional device For EQP EQPL models RS232 Wiring Configuration Baud Rate 9600 Parity None Stop Bit 1 Data Bit 8 11 5 4 3 2 1 9 8 7 6 SCALE 5 4 3 2 1 9 8 7 6 PC GND DATA OUT ...

Page 13: ...C outlet CHARGE LED will indicate the ongoing status of the battery It takes about 8 10 hours to fully recharge the battery CHARGE LED Color of LED Status of the battery RED Initial Connection ORANGE Charging GREEN Fully charged Power Requirements AC 220V 10 50Hz DC 6V 4Ah rechargeable battery P 0 2W max 12 ...

Page 14: ...EQC Counting Scale User Manual We do more than you expect Digital Counting Scale ...

Reviews: