                                                                                                                                                                                  HT(HPC)-100CT-2 Series    

   

 

HITROL CO., LTD.                                                                                1 

 

Doc. no : HT(HPC)100CT2_IM_Eng_Rev.5.1 

Issue date: 2021. 08 

HITROL CO., LTD. 

HEAD OFFICE.FACTORY.R&D INSTITUDE 
HITROL CO., LTD. 141, Palhakgol-gil, Jori-eup 
Paju-si, Gyeonggi-do, Korea   
TEL. : (00)-82-31-950-9700 
FAX. : (00)-82-31-943-5600 
www.hitrol.com 

 
 
 
 

INSTRUCTION MANUAL 

CAPACITANCE TYPE LEVEL TRANSMITTER 

HT-100CT-2 Series 

HPC-100CT-2 Series 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for HPC-100CT-2 Series

Page 1: ...e date 2021 08 HITROL CO LTD HEAD OFFICE FACTORY R D INSTITUDE HITROL CO LTD 141 Palhakgol gil Jori eup Paju si Gyeonggi do Korea TEL 00 82 31 950 9700 FAX 00 82 31 943 5600 www hitrol com INSTRUCTION MANUAL CAPACITANCE TYPE LEVEL TRANSMITTER HT 100CT 2 Series HPC 100CT 2 Series ...

Page 2: ...ating Principle 3 Specifications 4 Weather Proof Version 4 Ex Proof Version 4 Product Composition Technical Data 6 Installation 8 Precautions for Installation 8 Metal Tanks 9 Non metal Tanks 9 Wiring 10 Failure Check Maintenance 10 Precautions for Removal 11 Precautions for Transportation Assembly 11 Precautions for Attachment 11 Precautions for Grounding 11 Safety and Environment 11 Marking 12 Us...

Page 3: ... chemical and oil plants When there are two conductors insulated each other the value of capacitance formed between two conductors is a function of the sizes of two conductors relative location of two conductors and the dielectric constant of material placed between two conductors Under the conduction that air of dielectric ε exists in the space between two concentric conductors lower part of spac...

Page 4: ...ry PBT PF1 2 F IP65 AL PF 1 2 F IP66 PBT PF1 2 P IP65 AL PF 1 2 F IP66 AL PF1 2 F IP66 AL PF1 2 F IP66 Accuracy Up to 1 of F S Ex Proof Version Model HPC 100CT 2 HPC 100CTH 2 HPC 100CTW 2 HPC 100CTWH 2 Probe Type Rod Wire Mounting Screw or Flange Ambient Temperature 20 C 60 C Process Temperature 40 C 80 40 C 150 40 C 80 40 C 150 Process Pressure Vacuum 20kg cm2 300 Power Source DC 24V Output DC 4 ...

Page 5: ... Clamp Material 304 316L Others Housing Connection Probe High Temp Version High Temp Version Material Aluminum Rod Probe Rod Probe with Ground Rod Rod Probe with Ground Tube Wire Probe Wire Probe with Ground Wire Ground rod material SS w Teflon Ground tube material SS Wire material SS w Teflon Weight material SS Teflon Weight material SS Weight material Teflon Wire Probe with Ground Wire Corrosion...

Page 6: ... Sulfuric acid 84 The data of dielectric constant value can be downloaded from technical data by accessing our website www hitrol com Rod Probe Rod Probe w Ground Rod Rod Probe w Ground Tube Wire Probe Wire Probe w Ground Wire Total length L 100 3 000 100 3 000 100 3 000 1 000 15 000 1 000 15 000 Probe dia Ф15 Ф15 Ф15 Ф4 Ф4 Ground dia Ф10 Ф27 2 Ф4 For acid liquids O O O O For high viscosity liquid...

Page 7: ...ctual medium to be measured the measure value may be not correct Pay attention to the following matters during installation Product shall be installed at the place far from inlet in order to avoid the malfunction a Protection tube shall be applied if there is a flow or slopping of the medium of the tank b Probe shall be installed within Max 300mm from the tank wall f and ground tube type shall be ...

Page 8: ...n conductive tank as per above figure g Ground tube type shall be applied for ball tank and external chamber shall be installed for side mounting of tank h When side mounting the chamber shall be installed i The ground tube shall have vent holes in an appropriate location j g j Vent holes i h j Vent holes ...

Page 9: ...n a conductive tank the transmitter housing and tank shall be grounded as shown below 되어야 합니다 Non metal tanks Non conductive tank When installed on a non conductive tank use the ground tube rod or ground wire type Also the transmitter housing and tank shall be grounded as shown below ...

Page 10: ...hrough periodic inspections conducted at least once a year In addition check for the exterior of the product like visual damage If the medium or foreign substance is attached to the probe it will cause bad accuracy so it shall be removed regularly Be careful not to damage the Teflon part during removal Failure Check The level of measured object changes but the output does not change Insufficient p...

Page 11: ...hen connecting to an external ground the ground wire shall be 4 4mmSQ Check the level and presence of medium in the tank before removing it Wear gloves when removing it to prevent a burn If there is explosive gas atmosphere do not open the cover Disassemble work shall be done with the power off Make sure than any O ring or gasket is not damaged while opening or closing the cover of product HEAD We...

Page 12: ...the model name serial number working temperature working pressure and matters regarding output The serial number is a unique manufacturing number for the identification of products The fluid temperature of the container shall be up to 80 for Weather proof type For high temperature the fluid temperature shall not exceed 150 In addition make sure that the ambient temperature of housing is kept at 20...

Page 13: ...M 100CT2 User Manual Capacitance Type Level Transmitter Doc no Rev1 3 Issued Date 2021 07 15 APPENDIX V ...

Page 14: ...Cancellation 3 Key Span Set Setting the value left up 4 Key Zero Set Setting the value right down 5 LCD Display of operating and setting status 6 LED Display of power and status 7 UART Communication port of M 100CT2 setup and operation status 8 PWR For supply power and current output Check for output current 9 N A Not used ...

Page 15: ...2 Specification Table 1 Specification ...

Page 16: ...3 Configuration of Setting Menu Table 2 Setting Menu List ...

Page 17: ...4 Setting and Operating LCD Configuration Into the Setting Menu Return to Setting Mode ...

Page 18: ... Select the Setting Menu Change the User Setting Table 3 Key Button Guidance ...

Page 19: ... Height Setting Zero Span Quick Setting Setting by unit screen Factory shipping is set as unit setting Zero Setting Span Setting ...

Page 20: ... Zero Span Capacity fine Adjustment Zero Setting Span Setting Span Setting Other ...

Page 21: ...hod is the same using PC and Smartphone Password 1975 Run Screen Component You can check the sensor measurement status sensitivity setting value relay setting etc Monitoring Method Using PC Component PC USB Cable typical USB to Micro USB B UART ADAPTOR M 100CT2 PC UART Component M 100CT2 PC UART Run Screen USB Cable ...

Page 22: ...ime Set Zero Current Offset Adjustment Set Span Current Offset Adjustment Set Rotation Time Capacity Value of Current Measured Capacity Value of Zero Setting Capacity Value of Zero Setting Current Output of Current Value 01 Output select Setting Current Output of Value 01 Output select Setting Current Output of Lenght Value 01 Output select Setting Current Output of Feet Value 01 Output select Set...

Page 23: ...o Serial USB Terminal Install Setting Guide M 100CT2 Smartphone UART Component M 100CT2 Smartphone UART Execution M 100CT2 Smartphone UART Exit USB Cable Enter PW and Fly command Open App Home Screen Select UART Connection Enter Password Run Screen Enter exit command Exit Program Select UART Disconnection Enter exit and Fly command ...

Page 24: ...Doc no Rev0 0 Issued Date 2020 04 29 Serial USB Terminal Serial USB Terminal Install Setting Guide Application Level Switch Level Transmitter APPENDIX H ...

Page 25: ...SB Terminal App Search and Install a App that Serial USB terminal in the App Store Serial USB Terminal Setting Run The Serial USB Terminal Icon Four types of environments must be set up for normal operation of Serial USB Terminal Serial Terminal Receive Send ...

Page 26: ...rminal Show connection message Show timestamps Setting Show connection message ON OFF Show timestamps ON OFF The size of the Terminal Font is the size set in the Smartphone Terminal Setting Terminal Font Setting Default Complete Default Complete Default Setting Complete Select Baud rate ...

Page 27: ... no Rev0 0 Issued Date 2020 04 29 Receive Newline Setting Newline CR LF Carriage Return Line Feed Check Send Newline Setting Newline Auto same as Receive CR Select Newline Default Setting Complete Default ...

Page 28: ...al echo Clear input on send Setting Local echo ON OFF Clear input on send OFF ON Local echo Setting Clear input on send Setting For detailed instructions refer to the manual of each product Select Clear input on send Select Local echo Complete Complete Select Character delay Complete Setting Default ...