background image

SELF-CONTAINED MERCHANDISER

INSTALLATION & OPERATIONS MANUAL

To  ensure  proper  functionality  and  optimum  performance,  it  is  STRONGLY  recommended  that 

Hillphoenix

  display  cases  be  installed/

serviced by qualified technicians who have experience working with commercial refrigerated display merchandisers and storage cabinets.  

For a list of 

Hillphoenix

-authorized installation/service contractors, please visit our Web site at www.

Hillphoenix

.com.

O

 

HMA

 

-

 

N

 

RG

OHMAK-NRG

General Information  .......................................  2
Case Installation  .............................................  3
Case Connections  ..........................................  4
Pre-Power Checklist ........................................  5

Airflow, Defrost & Temp Control  ...................  6
Case Maintenance  ..........................................  7
Appendix  ......................................................... 8

Table of Contents

COMPONENT

CLA

SSIFIED

EPH

COMPONENT

P111801H

Summary of Contents for OHMA-NRG

Page 1: ...who have experience working with commercial refrigerated display merchandisers and storage cabinets For a list of Hillphoenix authorized installation service contractors please visit our Web site at www Hillphoenix com O HMA N RG OHMAK NRG General Information 2 Case Installation 3 Case Connections 4 Pre Power Checklist 5 Airflow Defrost Temp Control 6 Case Maintenance 7 Appendix 8 Table of Content...

Page 2: ...i e electronic or mechanical including photocopying recording or any other information storage and retrieval system without express written permission from Hillphoenix REVISION HISTORY ii VERSION 2 09 18 Updated data VERSION 1 05 18 new manual format VERSION 1 05 18 new manual format P111801H VERSION 3 11 18 Updated to add OHMAK NRG ...

Page 3: ...llphoenix authorized installation service contractors please visit our Web site at www hillphoenix com PRECAUTIONARY NOTICES At Hillphoenix the safety of our customers and employ ees as well as the ongoing performance of our products are top priorities To that end we call out important mes sages in all Hillphoenix installation and operations hand books with an accompanying alert symbol paired with...

Page 4: ...se the carrier may refuse the claim If damage becomes apparent after the equipment is unpacked retain all packing materials and submit a written request to the carrier for inspection within 14 days of receipt of the equipment LOST MISSING ITEMS Equipment has been carefully inspected to insure the high est level of quality Any claim for lost missing items must be made to Hillphoenix within 48 hours...

Page 5: ...3 Leveling is necessary to ensure proper case alignment and to avoid potential damage Locate the highest point on the positioning line as a reference for deter mining the proper height of the shim pack levelers A laser transit is recommended for precision and requires just one person 4 Locate the position of the base frame and spot properly leveled shim packs at the appropriate locations LINE UP I...

Page 6: ...important to note the outlet is specially molded with PVC material and the P trap is constructed of PVC Care should be given to make certain that all connections are water tight and are sealed with appropriate PVC primer and PVC cement Be certain that the case is properly leveled to ensure prop er drainage ELECTRICAL OHMA cases come pre wired with a NEMA L14 30P twist lock plug 250 volt 4 prong NE...

Page 7: ...r case functionality safety and com pliance with warranty terms Have you thoroughly examined the case for shipping damage see pg 2 Have you removed and discarded the casters see pg 3 Have you checked the vertical plumb of the case The horizontal level see pg 3 Have you removed any loose packaging or materials see pg 4 5 P111801H ...

Page 8: ...e monitors the temperature of the discharge air and may be used as the defrost termination sensor The probe can generally be found behind the rear baffle in the upper baffle or in front of the honeycomb For more detailed information on suggested defrost times and settings see Appendix A Further adjustment may be required depending on store conditions Fig 5 Obtain pressure and temperature readings ...

Page 9: ...l electrical power is turned off before cleaning In some installations more than one disconnect switch may have to be turned off to completely de energize the case Check waste outlet to insure it is not clogged before starting the cleaning process and avoid introducing water faster than the case drain can carry it away Avoid spraying cleaning solutions directly on electrical connections Allow case...

Page 10: ...Case Dimensions B1 B2 Electrical Wiring C1 SET POINTS D1 Sporlan Pressure Temperature Chart E1 DIXELL CASE CONTROLLER f1 f5 SEISMIC BRACKET INSTALLATION g1 peg hook information H1 INTERNAL CASE COMPONENT LAYOUT APPENDIX 8 P111801H ...

Page 11: ... Wiring to the top adds approximately 4 to case height A 2 minimum air gap is required between the rear of the case and a wall Back panels add approximately 1 to the rear of the case Available shelf sizes 18 20 22 Dashed line signify area inside base rail behind kick plate Casters add approximately 2 1 4 to case height Listed discharge air velocity represents the average velocity at the peak of de...

Page 12: ...ight Length Clearvoyant v4 LED Lighting Per Lifght Row Standard Power Cornice or Shelf High Power Cornice Only 120 Volts 120 Volts Amps Watts Amps Watts 2 3 0 08 9 4 0 20 23 8 GUIDELINES AND CONTROL SETTINGS 24 hour Energy Usage Suction Pressure Case Outlet psig Superheat Set Point Bulb Discharge Air Discharge Air Velocity 47 6 kWh 52 54 6 8 F 30 0 F 210 FPM CONDENSING UNIT DATA Volts Phase Freque...

Page 13: ... ELECTRICAL JUNCTION BOX 1 1 2 3 8 cm END CONDENSING UNIT DRAIN PAN Front of case 32 1 2 82 5 cm KICKPLATE LOCATION DRAIN EGRESS REFRIGERATION EGRESS Rev Rev Date Revision Description ALL MEASUREMENTS ARE TAKEN PER ASHRAE 72 2005 SPECIFICATIONS Hillphoenix REFRIGERATED DISPLAY CASES FOR SALE IN THE UNITED STATES MEET OR EXCEED DEPARTMENT OF ENERGY 2017 REQUIREMENTS COMPONENT OHMA NRG High Multi De...

Page 14: ... 2017 REQUIREMENTS COMPONENT OHMAK NRG High Multi Deck Self Contained Merchandiser 6 Meat OHMAK NRG 2 8 7 18 NEW STANDARDS 3 9 19 18 DATA UPDATE GENERAL NOTES indicates that the feature is not an option for this case model and or the data is not yet available LED lights only Maximum of 3 rows of standard output LED lighted shelves Nose lights are not available SHIPPING WEIGHT Case Weight OHMAK NRG...

Page 15: ... operational settings may need to be adjusted for the store conditions in which the case operates LIGHTING DATA Lights per row Clearvoyant v4 LED Lighting Per Light Row Standard Power Cornice or Shelf High Power Cornice Only 120 Volts 120 Volts Amps Watts Amps Watts 2 0 08 9 4 0 20 23 8 GUIDELINES AND CONTROL SETTINGS 24hr Energy Usage kWh Suction Pressure Case Outlet psig Superheat Set Point Bulb...

Page 16: ...in 2 Front Panel Type Contour Flat ColorBand Panel Finish CC Stainless Sill Cap Finish Stainless Painted Cornice Type Flat Curved Cornice Finish Painted Stainless Tank Finish Painted Aluminum Stainless Interior Color CC White Stainless Baffle Finish CC White Stainless Frame Finish CC White Flue Panel Finish CC White Stainless Deck Pan Type Plastic Metal Deck Pan Finish Color Black White Galvanized...

Page 17: ... Rev Rev Date Revision Description ALL MEASUREMENTS ARE TAKEN PER ASHRAE 72 2005 SPECIFICATIONS HILLPHOENIX REFRIGERATED DISPLAY CASES FOR SALE IN THE UNITED STATES MEET OR EXCEED DEPARTMENT OF ENERGY 2017 REQUIREMENTS COMPONENT OHMAK NRG High Multi Deck Self Contained Merchandiser 6 Meat OHMAK NRG 2 8 7 18 NEW STANDARDS 3 9 19 18 DATA UPDATE 34 1 4 33 5 8 ...

Page 18: ...4 109 9 cm 72 182 9 cm 32 1 2 82 6 cm 26 1 8 66 4 cm ELECTRICAL JUNCTION BOX DRAIN PAN CHIMNEY FOR HOT AIR EXHAUST 32 3 8 82 2 cm 1 1 2 3 8 cm END CONDENSING UNIT 1 1 2 PVC DRAIN CONNECTION 27 7 16 69 6 cm Rev Rev Date Revision Description ALL MEASUREMENTS ARE TAKEN PER ASHRAE 72 2005 SPECIFICATIONS HILLPHOENIX REFRIGERATED DISPLAY CASES FOR SALE IN THE UNITED STATES MEET OR EXCEED DEPARTMENT OF E...

Page 19: ...R SAFETY AND CODE COMPLIANCE GROUND FIXTURE AT TIME OF INSTALLATION CAUTION RISK OF ELECTRIC SHOCK MORE THAN ONE POWER SUPPLY DISCONNECT ALL POWER SUPPLIES BEFORE SERVICING P901598E R5 WIRE ID WIRING IDENTIFICATION B1 P111801H ...

Page 20: ...WIRING DIAGRAM B2 P111801H ...

Page 21: ...SET POINTS C1 P111801H ...

Page 22: ...81 8 17 8 3 16 4 51 5 54 3 30 4 388 0 18 7 8 17 0 52 7 55 6 31 4 394 3 19 7 2 17 7 54 0 56 9 32 4 400 7 20 6 7 18 4 55 3 58 3 33 5 407 2 21 6 1 19 1 56 6 59 6 34 6 413 8 22 5 6 19 9 58 0 61 0 35 7 420 4 23 5 0 20 6 59 3 62 4 36 8 427 1 24 4 4 21 3 60 7 63 8 37 9 433 8 25 3 9 22 1 62 1 65 3 39 0 440 7 26 3 3 22 9 63 5 66 7 40 2 447 6 27 2 8 23 7 64 9 68 2 41 4 454 6 28 2 2 24 5 66 4 69 7 42 6 461 7...

Page 23: ...DIXELL CASE CONTROLLER E1 P111801H ...

Page 24: ...ed The temperature range allowed for correct operation is 0 60 C Avoid places subject to strong vibrations corrosive gases excessive dirt or humidity The same recommendations apply to probes Let air circulate by the cooling holes 9 ELECTRICAL CONNECTIONS The instrument is provided with screw terminal block to connect cables with a cross section up to 2 5 mm2 Before connecting cables make sure the ...

Page 25: ...fault Display P1 P2 P1 Display delay 0 15 min 0 DEFROST Defrost type EL in EL Defrost termination temperature 55 50 C 67 99 F 8 0 C 46 F Interval between defrost cycles 0 99 hours 6 Maximum length for defrost 0 99 min 30 Start defrost delay 0 99 min 0 Display during defrost rt in SP dE it Drip time 0 99 min 0 Defrost at power on y n n ALARMS Maximum temperature alarm ALL 99 C ALL 99 F 99 C 99 F Mi...

Page 26: ... below Brackets are available for all base frame heights Constraint BraCKet attaCh to top of Case use 3 10 self tapping sCreWs attaCK BraCKet to Wall use 1 0 5 or 2 0 375 anChors Base frame Constraint BraCKet 2 per Case BraCKet shoWn here is for a 5 tall Base frame Constraint BraCKets are also aVailaBle for all Base frame heights use 3 10 self Drilling self tapping sCreWs for attaChment to the Bas...

Page 27: ...Seismic Bracket 5 F2 P111801H ...

Page 28: ...Seismic Bracket 7 F3 P111801H ...

Page 29: ...Seismic Bracket 11 F4 P111801H ...

Page 30: ...Seismic Bracket 15 F5 P111801H ...

Page 31: ...falls through openings between packages and fails to maintain a protective barrier When the bars are fully stocked the effect is minimized however product tem peratures will not be optimal Sweating may be noticed on the top duct panel above the bars and frost will build up on the coil faster requiring more frequent defrost cycles FIG 4 illustrates the proper set up for a display merchandiser with ...

Page 32: ...INTERNAL CASE COMPONENTS LAYOUT H1 P111801H ...

Page 33: ...NOTES P111801H ...

Page 34: ...es tax or upgrading 5 When the operation is impaired due to improper installation 6 When installation and startup forms are not properly complete or returned within two weeks after startup THIS PLAN DOES NOT COVER CONSEQUENTIAL DAMAGES Manufacturer shall not be liable under any circumstances for any consequential damages including loss of profit additional labor cost loss of refrigerant or food pr...

Page 35: ...directly on fan motors or any electrical connections All lighting components must be dried off prior to inser tion and re energizing the lighting circuit Please refer to the Use and Maintenance section of this installation manual BDM1219 Tel 1 800 283 1109 1925 Ruffin Mill Road Colonial Heights VA 23834 Due to our commitment to continuous improvement all specifications are subject to change withou...