background image

 

 

 

 

 

 

Instruction Manual

 

12,000 BTU Portable Air 

Conditioner

 

Model: HPAC12

 

 

READ AND SAVE THESE INSTRUCTIONS

 

 

Summary of Contents for HPAC12

Page 1: ...Instruction Manual 12 000 BTU Portable Air Conditioner Model HPAC12 READ AND SAVE THESE INSTRUCTIONS ...

Page 2: ... a similarly qualified person in order to avoid a hazard This appliance is for indoor use only Keep the appliance away from heat sources and direct sunlight Never insert fingers pencils or any other objects through the air vent guards whenever the power plug is connected especially while running Always switch off the appliance before unplugging it The appliance is not intended for use by young chi...

Page 3: ...n all directions The plug should be easily accessible In order to maintain the function of the compressor the appliance should always be in a vertical position Do not use the appliance near gas or other flammable liquids Do not block the air outlet or the air inlet ventilation Do not use spray insecticides paint or any other flammable products near the appliance as the plastic may become deformed ...

Page 4: ... key at cooling mode to increase reduce the setting temperature press it at timing mode to adjust timing ON OFF time press Up and Down keys simultaneously to switch Fahrenheit and Centigrade degree temperature 5 Mode button Press the key to choose cooling fan dehumidifying and auto mode 6 Timer button Press the key at standby mode to set TURN ON time Press this key set TURN OFF time when the unit ...

Page 5: ...from any surroundings Screw the exhaust pipe assembly into the air outlet in the back panel anticlockwise Insert the air exhaust hose into the window slider kit adjust the opening width of the window so that the window slider kit width matches properly the length of the kit is adjustable ...

Page 6: ...ing the remote control the wind indicator will light up Press the Speed button to choose High Low fan speed Temperature cannot be set when fan mode is selected Dehumidifying mode When pressing the mode button or choosing the dehumidifying mode by pressing the remote control the dehumidifying indicator will light up Remove the dehumidification water drainage nozzle insert the water pipe and place t...

Page 7: ...to utilize maximum cooling In Max Cool mode the A C will cool regardless of the temperature In Max Cool mode the fan speed is high and it cannot be adjusted Timer mode When the appliance is in standby mood press the button to turn the timer on Press the Up and Down keys to set the timer 0 24H and the timer indicator will light up Press the timer button to turn off the timer when the unit is on Wat...

Page 8: ...cooling efficiency of the appliance will be reduced Take out the air inlet grille and pull out the filters from both sides Wash the filters in warm soapy water neutral detergent dry it in a shady place once clean Seasonal Cleaning If the A C will not be used for a long time Straight after use pull out the water plug and drain the unit Run the A C on the fan mode for 2 hours until its dry inside Tu...

Page 9: ...et or air outlet blocked Remove the blockage The unit is too noisy Unit stands on an uneven surface Place on an even solid surface less vibration Compressor is not working Self protect of the compressor Wait for 3 minute and restart again after the descend of temperature Caution Switch off the unit and unplug it immediately if anything abnormal happens Then contact a qualified electrician Care Cle...

Page 10: ...Power Supply 220 240V 50Hz Noise 55dB A Rated input cooling 1450W Net weight 28 5kg Dimensions WxHxD 443x830x340mm Gross weight 33kg Fuse Parameters Specification Φ5 20mm Voltage 250VAC Current 3 15A Australian Customer Service GAF Control Sales Pty Ltd P O Box 19 Altona North Victoria 3025 Phone 1300 659 489 Hours 9am 5pm EST Mon Fri www gafcontrol com au This product may vary slightly to the pro...

Reviews: