manualshive.com logo in svg
background image

 

 

 

 

 
 
 

 

 

 

 

 
 

 
 

 

 
 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание LCSPC-120

Страница 1: ......

Страница 2: ...nd functions 11 User interface 12 Buttons 13 LCD icons 14 Controller operations 15 PARAMETER CHECKING AND ADJUSTMENT 16 Parameter list 16 ERROR CODES 17 MAINTENANCE 18 TROUBLESHOOTING 19 ENVIRONMENTAL...

Страница 3: ...ne friendly dramatically reducing Carbon Emissions Titanium heat exchanger The advanced titanium heat exchanger guarantees a longer life span free of corrosion It can be used with all types of water t...

Страница 4: ...staller Securing the Unit The unit should be located on a solid level horizontal surface and securely fixed Ensure free air flow to all sides of the unit Electrical Connections Ensure the correct size...

Страница 5: ...connections should be carried out as per the instructions in this manual Failure to do so could result in water damage to property Cleaning the Unit To prevent injury always shut the power OFF when cl...

Страница 6: ...NTS Before starting the installation please make sure that all items are found inside the box The Unit Box Item Image Quantity Swimming pool heat pump 1 Operation and Installation Manual 1 Accessories...

Страница 7: ...6 OVERVIEW OF THE UNIT EXPLODED VIEW ECO 30 55 70...

Страница 8: ...d controller 2 Electrical box 12 Compressor 3 Support frame 13 4 way valve assembly 4 Evaporator 14 Right panel 5 Left panel 15 Handle 6 Fan bracket 16 Titanium heat exchanger 7 Fan motor 17 Gas gauge...

Страница 9: ...y to avoid placing the unit under a tree or exposed to extreme conditions Water connection The heat pump is connected to a filtration circuit with a by pass It is imperative that the by pass is placed...

Страница 10: ...ts provided inside the heat pump to secure and route the supply cables Trial Running After connecting the unit to the pool system ensure your installation is complete with a suitable by pass and elect...

Страница 11: ...FF press to turn on the heat pump OFF mode ON mode 2 Turn OFF When the heat pump is ON press to turn off the heat pump ON mode OFF mode 2 Temperature Setting When the heat pump is on press or to chang...

Страница 12: ...ONS OF THE DIGITAL CONTROLLER WITH A HARD POINTED OBJECT THIS MAY DAMAGE THE DIGITAL CONTROLLER NEVER INSPECT OR SERVICE THE DIGITAL CONTROLLER YOURSELF REFER TO A QUALIFIED SERVICE ENGINEER Features...

Страница 13: ...he set temperature is reached 6 Error Indicator This icon will show when unit is failing and error code will show 7 Inlet Water Temperature Or Set Water Temperature This icon will show Inlet Water Tem...

Страница 14: ...ing mode temperatures timer setting and clock times are displayed on the screen NOTES HAS A STARTUP DELAY PLEASE WAIT FOR 3 MINUTES Press this button again when the unit is running and the unit will t...

Страница 15: ...defrost parameters can be altered 4 Left temperature display This display shows the current pool water temperature If you want to check or adjust the parameters this section will show the relating pa...

Страница 16: ...atus e Exit parameters settings automatically if no operation within 5 seconds Parameter settings will be invalid if the power fails within 10 seconds when adjusting parameters 2 button Press directly...

Страница 17: ...ing 30 90Min 40Min Adjustable 5 Defrosting entry coil temperature 30 not display 7 only display 7 Adjustable 6 Defrosting off coil temp 2 30 20 Adjustable 7 Defrosting max lasting time 0 15Min 8Min Ad...

Страница 18: ...ove P6 Protection for over high inlet outlet water temp difference 1 Too low water flow 2 Main PCB damaged 1 Check the water filter and water circuit no blockages 2 Replace the PCB P7 Ambient temp sen...

Страница 19: ...ing too high 5 Poor connection of pressure switch 6 Pressure switch failure 7 Main PCB damaged 1 Check pump and water control valve 2 Discharge and them recharge the refrigerant 3 Discharge some refri...

Страница 20: ...ection measures during the winter TROUBLESHOOTING This section provides useful information for diagnosing and correcting certain problems which may occur Before starting the troubleshooting procedure...

Страница 21: ...fluorinated greenhouse gas with a Global Warming Potential GWP 1975 DISPOSAL REQUIREMENTS Dismantling of the unit treatment of the refrigerant of oil and of other parts must be carried out in accordan...

Страница 22: ...21 WIRING DIAGRAM Please refer to the wiring diagram on the electric box Models LCSPC 40 LCSPC 55 LCSPC 70 LCSPC 95...

Страница 23: ...22 Models LCSPC 120 LCSPC 150 LCSPC 170...

Страница 24: ...23 Models LCSPC 210...

Страница 25: ...6 94 8 07 9 53 11 05 13 07 power input KW 0 84 1 04 1 35 1 97 2 18 2 79 3 37 4 18 EER 3 28 3 19 3 12 3 53 3 70 3 42 3 28 3 13 Power supply 220 240V 50Hz Max power input KW 1 05 1 36 1 84 2 33 2 71 3...

Страница 26: ...1 Contact details HeatPumps4Pools Ltd Rosemary Lodge Church Road Ramsden Bellhouse Essex CM11 1RT United Kingdom Tel 44 1268 206560 www HeatPumps4Pools com enquiries heatpumps4pools com...