Requirements

•  The light control requires 120-volts AC.
•  If you want to use Manual Mode, the control must be 

wired through a switch.

• 

Some  codes  require  installation  by  a  
qualified electrician.

•  This product is intended for use with the enclosed 

gasket and with a junction box marked for use in wet 
locations.

• 

Note: This product is not recommended for use where 
the outside temperature is below -10° F.

Model SL-5710

Light Control

Sensor

Cover Plate

Lamp Holders

Features

•  Turns on lighting when motion is detected.
•  Automatically turns lighting off. 
•  Photocell keeps the lighting off during daylight hours.
•  LED indicates motion was sensed (day or night).
•  Additional energy savings with compact fluorescent 

bulbs.

Motion Sensor
Light Control

Plastic Hanger

Rubber Plug

Gasket

6 Screws

(3 sizes included)

Mounting Strap

Mounting Bolt

2 Compact

Fluorescent Bulbs

2 Wire

Connectors

This package includes:

OPERATION

* resets to Auto Mode at dawn.

Note:  When first turned on wait about 1 

1

/

2

 minutes for 

the circuitry to calibrate.

MANUAL MODE

ON-TIME

10 5 1 TEST

10 5 1 

TEST

ON-TIME

TEST

... back on.

AUTO

1 Second 

OFF 

then...

Put the ON-TIME switch in the 1, 5, or 
10 minute position. 

Note: Although the 

1 minute mode can be used, the 5 or 
10 minute mode is recommended for 
best operation and performance when 
using compact fluorescent bulbs.

Put the ON-TIME switch on the bottom 
of the sensor in the TEST position.

Manual  mode  only  works  at  night 
because daylight returns the sensor 
to AUTO.

Flip the light switch off for one second 
then back on to toggle between AUTO 
and MANUAL MODE.

Manual  mode  works  only  with  the 
ON-TIME  switch  in  the  1,  5,  or  10 
position.

Move ON-TIME Switch to 

1, 5, or 10 minutes

Mode Switching Summary

Flip light switch off 

for one second then 

back on*

MANUAL MODE

AUTO

TEST

*  If you get confused while switching modes, turn the 

power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.

Mode:

On-Time

Works:

Day Night

Test

5 Seconds

x

x

Auto

1, 5, or 10 Min

x

Manual

Until Dawn*

x

Summary of Contents for SL-5710

Page 1: ...des OPERATION resets to Auto Mode at dawn Note When first turned on wait about 1 1 2 minutes for the circuitry to calibrate MANUAL MODE ON TIME 10 5 1 TEST 10 5 1 TEST ON TIME TEST back on AUTO 1 Second OFF then Put the ON TIME switch in the 1 5 or 10minuteposition Note Althoughthe 1 minute mode can be used the 5 or 10 minute mode is recommended for bestoperationandperformancewhen using compact fl...

Page 2: ...Black Gasket For eave mount only Swing the sensor head towards the clamp screw joint If the sensor pops out of the ball joint loosen the clamp screw and push the sensor back into the ball joint Tighten the clamp screw when done Then rotate the sensor head clockwise 180 so the controls face down Controls Wall Mount Eave Mount For under eave installation the sensor head must be rotated as shown in t...

Page 3: ...s and air conditioners These heat sources could cause false triggering Areas where pets or traffic may trigger the control Nearby large light colored objects reflecting light may trigger the shut off feature Do not point other lights at the sensor 180 70 ft 21 m 8 ft 2 4 m Turn the RANGE control to the mid position and the ON TIME control to the TEST position Loosen the clamp screw in the sensor b...

Page 4: ...ing Green KY 42102 9004 ATTN Technical Service If contacting Technical Service please have the following information available Model Number Date of Pur chase and Place of Purchase No Service Parts Available for this Product TEN YEAR LIMITED WARRANTY This is a Limited Warranty which gives you specific legal rights You may also have other rights which vary from state to state or province to province...

Page 5: ...NUAL ON TIME 10 5 1 TEST 10 5 1 TEST ON TIME Para PRUEBA préndalo Para AUTOMATICO 1 segundo APAGADO luego Ponga el interruptor de tiempo ON TIME en la posición de 1 5 ó 10 minutos Nota Aunque se puedeusarlamodalidadde1minuto se recomienda la de 5 ó 10 minutos paraobtenerelmejorfuncionamiento yrendimientocuandoseusenbombil las fluorescentes compactas Ponga el interruptor de tiempo ON TIME al fondo ...

Page 6: ...hacia la unión del tornillo sujetador Sieldetectorsesaledelauniónesférica aflojeeltornillo sujetador y empuje el detector hacia dentro de la unión esférica Apriete el tornillo sujetador cuando termine Entonces gire la cabeza del detector hacia la derecha por 180 hasta que los controles miren hacia abajo Controles Montaje en pared Montaje en alero Para instalarlo bajo el alero la cabeza del detecto...

Page 7: ...de operación PRUEBA AUTOMATICO y MODO MANUAL Retardo de Tiempo 1 5 ó 10 minutos Alcance Ajustable HeathCo LLC se reserva el derecho de descontinuar productos y de cambiar especificaciones a cualquier momento sin incurrir en ninguna obligación de tener que incorporar nuevas características en los productos vendidos con anterioridad Alcance Máximo Angulo de Cobertura Máxima NOTA El detector tiene un...

Page 8: ...M a 4 30 PM CST L V Usted puede también escribir a HeathCo LLC P O Box 90004 Bowling Green KY 42102 9004 ATTN Technical Service Servicio Técnico Si se llama al Servicio Técnico por favor tener lista la siguiente información Número de Modelo Fecha de compra y Lugar de compra No hay piezas de servicio disponibles para este producto GARANTÍA LIMITADA A 10 AÑOS Esta es una Garantía Limitada que le da ...

Page 9: ...du détecteur Le mode manuel ne fonctionne que la nuit parce que la lumière du jour remet le capteur en mode AUTO Mettre l interrupteur hors circuit pendant une seconde plus en circuit pour alterner entre les modes AUTO et MANUEL Le mode manuel ne fonctionne qu avec l interrupteur ON TIME aux positions 1 5 ou 10 Placer l interrupteur ON TIME à 1 5 ou 10 minutes Résumé du mode de commutation Mettre ...

Page 10: ...u détecteur en direction du joint à vis de blocage Si le détecteur sort de la rotule desserrer la vis de blocage et ré insérer le détecteur dans la rotule et resserrer la vis Puis faire pivoter le détecteur sur 180 de façon que les commandes soient tournées vers le bas Commandes Montage mural Montage sous avant toit Pouréviterlerisquedechocélectrique lescommandes du détecteur doivent être tournées...

Page 11: ...etpriorité manuelle Délais 1 5 et 10 minutes Portée Réglable HeathCo LLC se réserve le doit d abandonner tout produit et d en changer les spécifications en tout temps et sans contracter quelque obligation que ce soit quant à l incorporation de nouvelles caractéristiques aux produits déjà vendus NOTE Lecapteurdoitseréchauffer1 1 2 minuteavant de pouvoir détecter le mouvement Lorsque l appareil est ...

Page 12: ...ng Green KY 42102 9004 ATTN Technical Service Service technique Lors d un appel au service technique veuillez avoir les renseignements suivants à portée de main numéro du modèle date d achat et endroit de l achat Aucune pièce de rechange n est disponible pour ce produit GARANTIE LIMITÉE DE 10 ANS Il s agit d une Garantie limitée qui vous confère des droits juridiques spécifiques Vous pouvez égalem...

Reviews:

Related manuals for SL-5710