background image

www.hearandlearn.com.au

UConnect, 955, Redcat, Topcat & SoundHouse are part of the 

www.hearandlearn.com.au

 technology family.  

Offices Australia wide (03)93709355

Hole cutout size for basket  

H250 x W285 x D80mm

Hear and Learn UConnect Mini & RedCat

Precabling / Wiring Instructions

250mm

290mm

285mm

325mm

TV

PA

4

5

3

2

1

UConnect Mini mounted on  

classroom wall 1000mm  

from the bottom edge to  

the floor unobscured and  

in line of the sight of the  

occupants of the room

80mm

Hole cutout 

size 30mm

RedCat

230mm

405mm

Mount in the middle of longest wall

GPO required  

at mounting 

location of  

RedCat

Finished look of UConnect Mini.

Power to rear of UConnect

UConnect Mini comes premade with 2 x dual GPO’s. 

These GPO’s are to be installed inside the UConnect  

basket once connected to power. These GPO’s power  

the UConnect Mini itself (and its internal electronics).

Feed from PA speaker in the room.

UConnect Mini needs to receive a feed from the PA speaker 

in the room. Run cable (supplied by others) from the rear  

of the PA speaker location to the rear of the UConnect Mini.  

Cable is connected to UConnect Mini using terminal built 

into UConnect Mini.

Audio from AV device (TV/Projector)

Where cable length from AV device to rear of UConnect 

Mini is less than 10 metres, run a 3.5 stereo male cable 

supplied by Hear and Learn. Where cable length from AV 

device to rear of UConnect Mini is more than 10 metres, 

run CAT6 (supplied by others) and at each end connect 

audio extenders. Connection of cable to AV source to be 

determined/completed by others.

Connecting RedCat

3.5mm male to 3.5mm male cable from output on right 

side of RedCat Access to rear of UConnect Mini when cable 

length from RedCat to rear of UConnect Mini is less than 

10 metres. When cable length from AV device to rear of 

UConnect Mini is more than 10 metres, run CAT6 (supplied 

by others) and at each end connect audio extenders.

A. HOLES IN WALLBOARD

UConnect Mini must be installed in an unobscured location 
to allow line of sight to the UConnect Mini. It is for everday 

use and accessible to teachers and students.

UConnect Mini is an all in one, Premade hearing augmentation hub 

which comes to site at the last stage of construction. The basket 

shown is screwed to sides of vertical and horizontal studs with the 

rim of the hub overhanging over the front of the studs by the same 

thickness as the wallboard being used. For example, if you are using 

10mm Gib Board, ensure that the rim sits out by 10mm. Wallboard 

must surround the hub and not overlap the basket. 

Dimensions of the basket for the purpose of the hole in the wallboard 

is 285 mm x 250 mm. Depth of basket is 80 mm. A frame screws to the 

basket,  and plate (complete with storage box) clips into the frame. 

Hearing aided children can connect transmitters to receive  

augmentation of audio direct to receivers built into hearing aids.

Holes for UConnect Mini basket/wall plate system.

285mm x 250mm hole to surround the basket, with  

bottom edge of system 1000mm approx from the floor.

B. PRECABLING

2

1

3

4

5

Redcat Access 

mounts to the 

wall using  

brackets shown

.

Redcat Access Wall Mounting Instructions

Detailed instructions at www.hearandlearn.com.au/install

Approx 1800mm from floor.  

Within reach but safe from knocks.

Reviews: