background image

GLO-RAY

®

INFRARED FOODWARMER

APPLICATION INFORMATION

Hatco Glo-Ray

®

Infrared Foodwarmers are available in a variety of sizes and combinations to fit holding areas

of any length or depth. Some of the installation possibilities are described on this sheet. For more application
information contact your local Representative or the Hatco Corporation

.

AVAILABLE SIZES

WIDTH: 

Aluminum Housing — 

18"-12' (457-3,658 mm)

.

Available in 6" (152 mm) increments – 

single extrusion. 

Stainless Steel Housing

— 24", 36", 48", 60", 72", and 96" (610, 914, 1219, 1524, 1829, 

and 2438 mm) only.

DEPTH:

Aluminum —

6" or 9" (152 or 229 mm) or combinations using 3" or 6" (76 or 152 mm) 

spacers. 

Stainless Steel —

6" (15 cm) only.

Incandescent lights are available for aluminum models only and can be ordered on either side of unit. Center

lights recommended for dual warmer mounting. The 60-watt incandescent shatter-resistant bulbs provide
illumination only and feature a special coating that guards against injury and food contamination in the event
of breakage.

MIN. 18" (457 mm)

(152 mm)

MAX. 144" (3,658 mm)

Summary of Contents for Glo-Ray GRA-108

Page 1: ...in 6 152 mm increments single extrusion Stainless Steel Housing 24 36 48 60 72 and 96 610 914 1219 1524 1829 and 2438 mm only DEPTH Aluminum 6 or 9 152 or 229 mm or combinations using 3 or 6 76 or 152...

Page 2: ...ousings STANDS A variety of optional stands are available for permanent and portable installation Available for both standard and high wattage elements CAUTION Do not install Glo Ray warmers less than...

Page 3: ...contain tandem end to end elements individually controlled High temp wire 90 C minimum must be used for power connections SWITCHES Glo Ray Foodwarmers include an on off toggle switch as standard Cons...

Page 4: ...YES GRA 30 240 450 1 9 YES GRA 36 120 575 4 8 YES GRA 36 208 575 2 8 YES GRA 36 240 575 2 4 YES GRA 42 120 675 5 6 YES GRA 42 208 675 3 2 YES GRA 42 240 675 2 8 YES GRA 48 120 800 6 7 YES GRA 48 208...

Page 5: ...0 950 4 0 YES GRAH 48 120 1100 9 2 YES GRAH 48 208 1100 5 3 YES GRAH 48 240 1100 4 6 YES GRAH 54 120 1250 10 4 YES GRAH 54 208 1250 6 0 YES GRAH 54 240 1250 5 2 YES GRAH 60 120 1400 11 7 YES GRAH 60 2...

Page 6: ...lications and 220V or 240V for export aplications INDICATOR LIGHT REMOTE CONTROL BOX Recommended for Dual models and Infinite Switch CORD PLUG 120V 72 1829 mm unit or less with C Leg or T Leg stand on...

Page 7: ...NOTES 7 Form No GRAB 0804...

Page 8: ...GRAB 0804 DANIEL C GREEN AGENCY Territory W PA WV excluding Morgan Berkley Jefferson counties Pittsburgh PA 412 364 6094 FAX Number 412 364 4532 THE HGA GROUP INC Territory IN excluding Lake Porter c...

Reviews: