manualshive.com logo in svg
background image

P

lenum

P

lus

Commercial Grade

Condensate Removal Pumps

(KL-1DG-115, KL-1DG-230 and KL-1DG-277)

IOM Manual

Manual No.  : 52200

Rev. 

 

A

Rev. Date  : 

2019

Содержание PlenumPlus KL-1DG-115

Страница 1: ...PlenumPlus Commercial Grade Condensate Removal Pumps KL 1DG 115 KL 1DG 230 and KL 1DG 277 IOM Manual Manual No 52200 Rev A Rev Date 2019 ...

Страница 2: ...e does not apply if the product has been misapplied or mechanically damaged HARTELL assumes no liability for resultant damages of any kind arising out of the use of its products ONE YEAR LIMITED WARRANTY SECTION 1 INTRODUCTION 1 SECTION 2 INSTALLATION AND OPERATION 2 2 1 INSTALLATION 2 2 1 1 Piping 2 2 1 2 Electrical Connections 3 2 1 3 Line Voltage 3 2 1 4 Low Voltage Auxiliary Safety Switch 3 2 ...

Страница 3: ... the precautions listed below before continuing READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING INSTALLATION 1 Pumpshouldonlybeusedwithliquidscompatible with pump component materials Do not use to pump flammable or explosive fluids Do not use in explosive atmospheres 2 The pump is supplied with Pigtails to hard wire the pump To reduce the risk of electrical shock be certain that it is connected to...

Страница 4: ...t close off against the bottom of the pump Connect tubing to the check valve Extend this tubing straight up as high as necessary Do not extend this tubing past the head GPH of the pump installed Do not kink the tubing as this will block the flow From this high point slope the discharge tubing downward to a point above the drain then turn down and extend to a point below or level with the bottom of...

Страница 5: ... thermostat demand in a high water condition Figure 3 Condensate Pump Wire Nut From Thermostat Yellow Yellow Furnace A C Red White Green Yellow Figure 3 T hermostat demand disruption should not be utili z ed if cooling or heating re q uirements are a necessity A n alarm system should be used with the au x iliary switch instead 2 2 OPERATION After proper installation the operation of the HARTELL co...

Страница 6: ... algae formation Flush the reservoir with warm water and a mild soap or detergent See note from point 3 2 3 2 PUMP MOTOR RUNS WITH NO DISCHARGE 1 Inspect the discharge tubing for its full length to make sure it is clear make sure the tubing end is not plugged 2 Make sure the check valve is not clogged If clogged UNPLUG THE PUMP remove the fitting and clean with mild soap or detergent See note belo...

Отзывы: