background image

ITEM #2599777

MODEL #HTD20005

KENTON CEILING FAN

Harbor Breeze® is a registered trademark

of LF, LLC. All Rights Reserved.

1

Español p. 18

Questions, problems, missing parts?

Before returning to your retailer, call our customer 

service department at 1-800-643-0067, 8 a.m. - 8 p.m., EST, Monday - Sunday. 

ATTACH YOUR RECEIPT HERE

Serial Number

Purchase Date

VR20245

Summary of Contents for 2599777

Page 1: ...tered trademark of LF LLC All Rights Reserved 1 Español p 18 Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 643 0067 8 a m 8 p m EST Monday Sunday ATTACH YOUR RECEIPT HERE Serial Number Purchase Date VR20245 ...

Page 2: ...ions Wiring Instructions Final Installation Instructions Operation Instructions Care and Maintenance Troubleshooting Limited Lifetime Warranty FCC Warning Safety Information 4 Package Contents Hardware Contents 3 4 5 6 8 9 11 13 14 15 16 Replacement Part List 17 ...

Page 3: ...ote Unit 3 PART DESCRIPTION QUANTITY 1 H Trim Ring Preassembled on Motor Assembly B 4 I Mounting Screw Preassembled on Motor Assembly B 3 J Mounting Plate Screw Preassembled on Motor Assembly B 3 K Switch Housing Screw Preassembled on Switch Housing C A K C B E F D G I H J PART DESCRIPTION QUANTITY X2 X6 CR2032 3V ...

Page 4: ...The lighting fixture must be positioned so there is at least 1 64 ft between the bulb and any illuminated surface For supply connections if the conductor of a fan is identified as a grounded conductor then it should be connected to a grounded conductor power supply If the conductor of a fan is identified as an ungrounded conductor then it should be connected to an ungrounded conductor power supply...

Page 5: ...an cause severe internal burns and can lead to death in as little as 2 hours Always completely secure the battery compartment If the battery compartment does not close securely stop using the product remove the batteries and keep it away from children If you think batteries might have been swallowed or placed inside any part of the body seek immediate medical attention Dispose of cells properly an...

Page 6: ...urn off circuit breakers and wall switch to the fan supply line leads installation may result in serious injury or death or T Turn Off Power Source 3 Check existing outlet box not included to ensure it is securely fastened to at least two points in a structural ceiling member and can support the full weight of the fan Once verified install ceiling plate A to the outlet box using the screws and was...

Page 7: ...nting screws I on the round holes keep for later use And loosen the other two screws I 5 Hang the motor assembly B onto the hook from the ceiling plate A This will allow for hands free wiring INITIAL INSTALLATION INSTRUCTIONS I B I B A 4 5 ...

Page 8: ... it must be grounded for safe operation WARNING If house wires are different colors than referred to in the following steps stop immediately A professional electrician is recommended to determine proper wiring WARNING If you feel that you do not have enough electrical wiring knowledge or experience have your fan installed by a licensed electrician 2 1 Follow steps below to wiring your fan once wir...

Page 9: ...kwise until the screw heads engage the keyhole slots fully Make sure not to break any wire connections 2 Re install two mounting screws I to the round holes securely tighten four 4 mounting screws I 9 FINAL INSTALLATION INSTRUCTIONS 1 1 2 A A I I B 3 Lift the trim ring H up aligning four notches on the canopy of motor assembly B with raised areas on the inner side of trim ring H and pop it into th...

Page 10: ...AL INSTALLATION INSTRUCTIONS B J 6 Insert the 9 pin connector from the motor assembly B through the center hole in the switch housing C Attach the switch housing C to the mounting plate on the motor assembly B by placing the keyhole slots from the switch housing C onto the two protruding mounting screws J heads Adjust the switch housing C until the screw heads are aligned with the keyholes then re...

Page 11: ...C by twisting in a clockwise direction Do not over tighten FINAL INSTALLATION INSTRUCTIONS 7 C E K 8 C F OPERATION INSTRUCTIONS 1 When the season changes you may want to change the direction in which the fan spins In warmer weather counterclockwise rotation creates a downward airflow which cools the air Push the switch LEFT and see a SUN icon In cooler weather clockwise rotation creates an upward ...

Page 12: ...ltiple fans installed within a close proximity and want to control all fans using a same remote transmitter NOTE Each fan requires its own receiver NOTE sure battery is not flat After you have replaced a faulty transmitter or receiver with a new one Otherwise the remote control will not work To perform this process manually follow steps below After installing and wiring the unit restore power to y...

Page 13: ...M with dimmer function b on ON without dimmer function Note Factory set is on DIM position If the light is not dimmable slide it to ON position otherwise it may cause the light to flicker CARE AND MAINTENANCE Important Shut off main power supply before beginning any maintenance Do not use water or a damp cloth to clean the ceiling fan At least twice each year tighten all screws and lower canopy to...

Page 14: ... Blade is loose 5 Check that all blades are screwed firmly into blade holders Fan sounds noisy Fan wobbles TROUBLESHOOTING PROBABLE CAUSE CORRECTIVE ACTION PROBLEM 6 Blade holders are loose 6 Check to be sure the fan blade irons seat firmly and uniformly on the surface of the motor If flanges are seated incorrectly loosen the flange screws and retighten 7 Blade out of balance 7 Interchange two adj...

Page 15: ...changes in brass finish rusting pitting tarnishing corroding or peeling Brass finish fans maintain their beauty when protected from varying weather conditions The duration of any implied warranty which can not be disclaimed is limited to the lifetime limited period as specified in our warranty The manufacturer shall not be liable for incidental consequential or special damages arising at or in con...

Page 16: ... FCC Rules These limits are designed to provide reasonable protectionagainst harmful interference in a residential installation The remote control generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user ...

Page 17: ...00 643 0067 8 a m 8 p m EST Monday Sunday A Ceiling Plate A102 0365036 C Switch Housing A121 0470213 D Blade A141 0641030 E Light Kit A187 0516036 F Bowl A182 0502036 G Remote Unit A137 0540032 AA Blade Screw B166 1062018 Part Description Part Printed in China AA A C E F D G X2 X6 CR2032 3V ...

Page 18: ......

Reviews: