background image

AQ sound FS S
Hearing aid guide

AQ sound FS S
AQ sound FS S myChoice
HANSATON S Charger

Summary of Contents for AQ sound FS S

Page 1: ...AQ sound FS S Hearing aid guide AQ sound FSS AQ sound FSS myChoice HANSATON S Charger...

Page 2: ...r hearing aid or charging accessories please askyour hearing care professional The hearing aids described in this user guide contain a built in and non removable rechargeable lithium ion battery Pleas...

Page 3: ...product Table of contents 1 Quick guide 2 2 Parts of the hearing aid and charger 4 3 Preparing the charger 8 4 Charging the hearing aids 10 5 Left and right hearing aid markings 13 6 Putting your hea...

Page 4: ...Multi function button Charging your hearing aids Place the hearing aids in the charger Charging Slow blinking indicator light Fully charged Solid green indicator light On Off Left right hearing aid ma...

Page 5: ...etween listening programs changes the volume level and accepts or rejects mobile phone calls depending on your customized fitting 4 Wire connects the speaker unit to your hearing aids 5 Dome holds the...

Page 6: ...al power supply Power supply specification Power supply input voltage 100 240 VAC 50 60 Hz current 0 25 A Power supply output voltage 5 VDC 10 current 1 A Charger input voltage 5 VDC 10 current 500 mA...

Page 7: ...ions in the table on previous page page 7 Low power You will hear two beeps when the battery is low You will have approximately 60 minutes before you have to charge the hearing aids this can vary depe...

Page 8: ...Charging the hearing aids Using the charger The charging process will automatically stop when the batteries are fully charged so the hearing aids can be safely left in the charger It can take up to 3...

Page 9: ...the power supply from the power outlet Indicator light Charging state Approximate charging times 0 10 11 80 30 min 25 60 min 50 90 min 75 81 99 100 3 h 5 Left and right hearing aid markings There is a...

Page 10: ...ntly push the dome into your ear canal The wire should lie flush against your head and not stick out 3 If there is a retention piece place it in your ear so it rests at the bottom of the opening of yo...

Page 11: ...ll accept an incoming call and a long press will reject an incoming call Program control If your multi function button is a program control each time you push the button on either hearing aid for long...

Page 12: ...ing volume down short beep Maximum volume level 2 beeps Minimum volume level 2 beeps Program volume control push button If your hearing care professional has configured one hearing aid to be a program...

Page 13: ...ng aid Press and hold the button until the indicator light turns solid red signifying that the hearing aid is switching off Blinking green Hearing aid is switching on Solid red Hearing aid is switchin...

Page 14: ...The HANSATON stream remote App can be used on phones with Bluetooth Low Energy LE capability Please find phone compatibility details on hansaton com support Please find the instruction for use on han...

Page 15: ...stered trademark owned by the Bluetooth SIG Inc It is only necessary to perform the pairing procedure once with each Bluetooth enabled phone After the initial pairing your hearing aids will connect au...

Page 16: ...oice through their own microphones You do not need to holdyour mobile phone close to your mouth your voice is transmitted through the hearing aids to your mobile phone Caller s voice Your voice Making...

Page 17: ...ort push of less than 2 seconds on the multi function button on either hearing aid Alternatively accept the call on your phone as you normally would Ending a call A call can be ended by tapping the to...

Page 18: ...ode will not disable normal hearing aid functionality only the Bluetooth connectivity functions Entering flight mode To enter flight mode follow these steps for both hearing aids seperately 1 If the h...

Page 19: ...aring aid is in an error state This will not remove or delete any program or settings 1 Press the button for at least 15 seconds It does not matter if the hearing aid is switched on or off before you...

Page 20: ...n condensing 0 to 70 0 to 70 0 to 60 non condensing 0 to 60 non condensing 0 to 60 0 to 60 Atmospheric pressure 500 hPa to 1060 hPa 500 hPa to 1060 hPa 500 hPa to 1060 hPa 500 hPa to 1060 hPa Please e...

Page 21: ...r devices Sonova AG will provide a minimum of a five year repair service period after the respective hearing aid charger and essential components have been phased out of the product portfolio Before u...

Page 22: ...drying capsules Charger Makesure thatchargerinserts are clean Never usecleaningagentssuch as household detergents soap etc forcleaningyour charger Weekly Hearing aid Clean the dome with a soft damp cl...

Page 23: ...if it looks dirty or if the hearing aid volume or sound quality is reduced The earwax protection should be replaced every four to eight weeks on a regular speaker 1 Remove the dome from the speaker b...

Page 24: ...3 Toinsertanewearwax protectorcarefullyinsertthe speakerintotheopening wherethenewearwax protectorisvisible opposite thebinicon untilitclicks Aftertheclickyouwillseetheopeningbelow isemptyandthenewear...

Page 25: ...national warranty does not affect any legal rights that you might have under applicable national legislation governing sale of consumer goods Warranty limitation This warranty does not cover damage fr...

Page 26: ...cause undesirable operation Notice 2 Changes or modifications made to this device not expressly approved by Sonova AG may void the FCC authorization to operate this device Notice 3 This device has bee...

Page 27: ...HFP Hands free profile A2DP Compliance with emission and immunity standards Emission standards EN 60601 1 2 IEC 60601 1 2 EN 55011 CISPR11 CISPR32 CISPR25 EN 55025 CISPR25 2016 Immunity standards EN 6...

Page 28: ...code of certified institutions that were consulted under the above mentioned regulation and directive This symbol indicates that the products described in these user instructions adhere to the require...

Page 29: ...fied radio equipment This symbol indicates that this is a Prescription Device CAUTION U S Federal law restricts this device to sale by or on the order of a physician or hearing care professional for U...

Page 30: ...symbol indicates that it is important for the user to pay attention to the relevant warning notices related to batteries in these user guides Symbols applicable to the European power supply only Powe...

Page 31: ...cess Chapter 16 Cause Possible remedy Issue Indicator light on hearing aid does not light up when hearing aid placed in charging inserts Hearing aid not inserted correctly into charger Insert hearing...

Page 32: ...life Contact your hearing care professional A battery replacement may be required Issue Phone call function does not work Hearing aid is in flight mode Switch hearing aid off and then on again Hearin...

Page 33: ...nd bilateral mild to severe hearing loss from 8 years of age The tinnitus software feature is intended for patients with chronic tinnitus from 18 years of age Charger The intended patient population i...

Page 34: ...patient for a medical or other specialist opinion and or treatment are as follows Visible congenital or traumatic deformity of the ear History of active drainage from the ear in the previous 90 days...

Page 35: ...eral well being The records confirm that all necessary considerations about the patient s best interests have been made If legally required the patient has signed a disclaimer to confirm that the refe...

Page 36: ...benefit from it The use of a hearing aid is only part of hearing habilitation and may need to be supplemented by auditory training and instruction in lipreading Feedback poor sound quality too loud or...

Page 37: ...rator requires devices to be switched into flight mode see chapter 15 The hearing aids specially programmed for each hearing loss must only be used by the intended person They should not be used by an...

Page 38: ...lators etc Keep the wireless hearing aid and charger at least 15 cm 6 inches away from the active implant If you experience any interference do not use the wireless hearing aids and contact the manufa...

Page 39: ...nymore in your country please refer to IEC 62368 1 Hearing aids should not be fitted with domes wax protection systems when used by clients with perforated eardrums inflamed ear canals or otherwise ex...

Page 40: ...ces may be damaged Your hearing aid s contain a lithium ion battery with a Watt hour rating 20 Wh which have been tested according to UN 38 3 of the UN Manual of Tests and Criteria and should be shipp...

Page 41: ...to risk of fire or explosion Ask your hearing care professional about suitable drying methods Do not place the charging accessories close to an induction cooking surface Conductive structures inside...

Page 42: ...aring aid users have reported a buzzing sound in their hearing aids when they are using cell phones According to the ANSI 63 19 American National Standard Methods of Measurement of Compatibility betwe...

Page 43: ...ent therapy that can be used as part of a personalized tinnitus management program to provide temporary relief from Tinnitus The underlying principle of sound enrichment is to provide supplementary no...

Page 44: ...evel in your hearing aids your hearing care professional will advise you of the maximum amount of time per day you should use the Tinnitus masker The Tinnitus masker should never be used at uncomforta...

Page 45: ......

Page 46: ...Evertone Pty Ltd 15 51 53 Spring St Bondi Junction NSW 2022 Australia And importer for European Union Sonova Deutschland GmbH Max Eyth Str 20 70736 Fellbach Oeffingen Germany Pat www sonova com en in...

Page 47: ...Manufacturer Sonova AG Laubisr tistrasse 28 CH 8712 St fa Switzerland www hansaton com 7 6 1 3 3 8 9 6 2 8 0 7 4 029 6726 02 V1 01 2023 04 cz...

Page 48: ...ryan Hynes 1 09 May 2023 Coordinator Information Control 53BHYNES Janette Brookes 2 09 May 2023 Technical Administrator Information Control 53HPARMAR Zeljko Nadjmico 2 09 May 2023 Manager Quality Assu...

Reviews: