background image

 

PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE

 

Operating & Installation Manual 

BK055

 

Rev 06 

November 2009 

Part No. AFS1297

 

   

RANGE OF STOVES 

Camborne Deluxe 

Camborne Deluxe Medium (Pictured) 

Summary of Contents for BK055

Page 1: ...PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE Operating Installation Manual BK055 Rev 06 November 2009 Part No AFS1297 RANGE OF STOVES Camborne Deluxe Camborne Deluxe Medium Pictured...

Page 2: ...please contact the Hamlet retailer in your area or call our technical support department on 0844 8475107 Copyright 2008 Arada Ltd This booklet has copyright and may not be copied in whole or part or...

Page 3: ...Chimney Sweeping 18 Door Glass 18 Outer Finish 18 Summer Storage Non Usage 19 Adjusting the Door Hinges 19 Disassemble The Airwash 20 Centre Fire Door Rope Replacement 20 Fire Door Rope Replacement 21...

Page 4: ...HETAS IF IN DOUBT CONTACT HETAS LIMITED TELEPHONE NUMBER 0845 634 5626 www hetas co uk THIS STOVE MUST NOT BE CONNECTED TO A SHARED FLUE SYSTEM TO ALL USERS PETROLEUM COKE SOME OF WHOSE BRAND NAMES AR...

Page 5: ...odern equipment available It is a highly efficient and sophisticated piece of machinery and when properly installed and operated it should provide a lifetime of heating satisfaction Safety is the most...

Page 6: ...Deluxe Compact Camborne Deluxe Small Camborne Deluxe Medium Camborne Deluxe Large 1 Fuel Retainer 2 2 2 2 2 Grate Bars 5 7 9 11 3 Throat plate 1 1 1 1 4 Flue Spigot 1 4 1 5 1 5 1 6 5 Hot Plate 1 4 1...

Page 7: ...Camborne Deluxe Compact Camborne Deluxe Small Camborne Deluxe Medium Camborne Deluxe Large 9 Rear Liners 1 2 2 2 10 Side Liners 2 2 2 2 11 Rear Grate bar support 1 1 1 1 12 Comb Assembly comprising of...

Page 8: ...t water add in boiler type 0 6 8 10 Max Oputput to Room kW 3 3 8 5 7 7 6 Max Oputput to Water kW 2 2 2 2 3 3 4 Height mm 505 530 552 552 Width mm 393 477 586 672 Depth mm 377 386 382 467 Height to Cen...

Page 9: ...ll be installed on a floor with adequate load bearing capacity If the existing construction does not meet this prerequisite suitable measures e g load distributing plate should be taken to achieve it...

Page 10: ...ware of this Failure to correct an over drawing flue will invalidate the warranty Please remember that chimney draught is dependent on four main factors Flue gas temperature Flue height Flue size Flue...

Page 11: ...ng details on the chimney flue lining hearth and fireplace installation Approved Docu ment J of the Building Regulations for England Wales is available from The Stationary Bookshops and can also be vi...

Page 12: ...shared flue system that serves any other heating appliance TYPICAL REAR FLUE OUTLET as per BS 8303 1 Maximum 150mm 6 Horizontal Flue Section Minimum 150mm 6 Diameter Flue Soot Door Fire Retardant Rop...

Page 13: ...r Plate 1 5mm Thick Minimum Non Combustible Register Plate Minimum 1 5mm Thick Steel TYPICAL TOP FLUE OUTLET as per BS 8303 1 Typical Metal Insulated Chimney System Installed To The Chimney Manufactur...

Page 14: ...and then lowering end marked L onto the low section of the comb see fig 3 The upper bar is fitted in a similar manner but with the end marked L inserted in the rear channel and the end marked H seate...

Page 15: ...ner panels See Fig 6 Fit the throat plate with the single bend and two cut outs to the front facing up The projecting lugs sit on top of the side liners The long centre tab on the back edge rests on t...

Page 16: ...2 mbar If Building Control Consent route is being sought please complete the check list on page 17 For a registered Competent Persons Scheme such as HETAS please complete the Certificate Of Complianc...

Page 17: ...Profession Capacity Telephone No Address Postcode Signed Date Registered member of e g CORGI OFTEC HETAS NACE NACS 7 Hearth Form of construction new or existing 8 Inspection and testing after completi...

Page 18: ...mportant that the flue ways flue pipe and chimney be cleaned prior to lighting the appliance after a prolonged shut down period DOOR GLASS The door glass should remain clear during normal burning Howe...

Page 19: ...or catch This is quite normal and due to the settling of the casting The fire door can be re aligned as follows When the appliance is cold open the fire door so that it is at right angles to the front...

Page 20: ...ng or replacement Refit using the reverse of this procedure Fig 11 Unscrew Control Knob Fig 12 Lifting Cover From Body Fig 13 Inner Slider Removal Hamlet Camborne Deluxe Stoves CENTRE FIRE DOOR ROPE R...

Page 21: ...seal to length and glue into position Allow 30 minutes before refitting the door to the appliance FIRE DOOR GLASS REPLACEMENT In the event of the door glass being broken it can easily be replaced Ple...

Page 22: ...amage and replace if necessary Clean the air slots within the door s casting and slider plate s Reassemble into the door and refit the control knob You will note that the slider can be locked to a sel...

Page 23: ...vered in this manual please contact your Hamlet dealer Please keep all repair receipts safely Please ensure you have this manual available when an engineer visits so they can complete the service reco...

Page 24: ...acturer For Further Details Advice On The Use Of Other Fuels For additional further advise on fuels please refer to HETAS Tel 0845 634 5625 or www hetas co uk or Solid Fuel Associa tion Tel 0845 601 4...

Page 25: ...be minimised by burning hard for a short period 15 to 20 minutes twice a day Please Note To avoid chimney problems your appliance should not be burnt at a reduced burn rate without a period of fast b...

Page 26: ...or household objects from falling embers The ash pan should be emptied at least twice a day or when the level of ash reaches the top of the ash pan On no account should the ash be allowed to build up...

Page 27: ...to the Right as in Fig 20 AIR WASH SYSTEM The air wash has an internal sliding plate with slots housed in a cover plate and is located above the fire door Sliding the control knob to the right as far...

Page 28: ...fe This operation should be carried out with the door doors closed to prevent dust escaping into the room Move up and down vigorously the riddling lever ash will fall into the ash pan beneath the grat...

Page 29: ...t be taken when opening and closing the fire door as any surrounding areas of the stove will be very hot WARNING Never attempt to open the fire door whilst the appliance is in use WITHOUT the use of t...

Page 30: ...AOCXSL AOCSL AOCML AOCLL N A AOCSH AOCMH AOCLH ECB5 WBTRAY ECB7 WBTRAY ECB9 WBTRAY ECB11 WBTRAY 30 Aerosol Touch Up Paint Add On High Canopy Add On Low Canopy Add In Slab Boiler Wood Burning Upgrade K...

Page 31: ...Large 1 Fuel Retainers AFS1190 AFS1192 AFS1191 AFS1240 2 Throat Plate AFS1018 AFS1019 AFS1020 AFS1241 3 Grate Bar Set AFS001 AFS001 AFS001 AFS002 4 Hot Plate AFS009B AFS009 AFS009 AFS012 5 Flue Spigo...

Page 32: ...set AFS1279 AFS1279 AFS1279 AFS1279 14 Airwash Kit AFS1280 AFS1280 AFS1280 AFS1280 15 Fire Door Rope Kit with Rope glue AFS1021 AFS1021 AFS1021 AFS1021 16 Left Hand Fire Door Complete N A See Note1 AF...

Page 33: ...Small Cam borne Deluxe Medium Cam borne Deluxe Large 20 Comb and Extension Bar AFS1274 AFS1276 AFS1291 AFS1301 21 Grate bar Support AFS1275 AFS1277 AFS1170 AFS1246 22 Stove Mitten AFS1285 AFS1285 AFS...

Page 34: ...checked annually by a qualified heating engineer with documentation to be retained and produced in the event of a claim being made Claims are not valid where installation does not conform to appropria...

Page 35: ...ion must be retained and produced in the event of a warranty claim This guarantee specifically does not cover accidental damage misuse wear tear The use of non Hamlet replacement parts will invalidate...

Page 36: ...late Fuel Retainers Firebox Liners Throat Plate Air Wash Ash Pan Operating Tool Operating Installation Manual Stove Mitten Assembled By Checked by Date of Purchase Name and Address of Supplier Arada L...

Reviews: