Features:

Electrionic  Control

  Front  Door  Design

3  Drying  Cycles

  4  Temperatures  Setting

End  Of  Drying  Signal

  Wrinkle  Care  Program

Electric  Clothes  Dryer

Service    Manual

RDE350AW

Serial  Number

:RDE350AW

Edition:  2008-08-08

Model:

Version:    A

8

 

 

Содержание RDE350AW - 6.5 Cu. Ft. Electric Dryer

Страница 1: ...onic Control Front Door Design 3 Drying Cycles 4 Temperatures Setting End Of Drying Signal Wrinkle Care Program Electric Clothes Dryer Service Manual RDE350AW Serial Number RDE350AW Edition 2008 08 08 Model Version A 8 ...

Страница 2: ...nt in installation adjustment and disassembly 6 8 Analysis of the common breakdowns 10 1 Specifiation list 1 2 Dimensional drawing 1 3 Circuit diagram 2 4 Names of parts 2 5 Usage of the operation knobs 3 6 Products brief and new features 4 7 Key point in installation adjustment and disassembly 6 8 Analysis of the common breakdowns 10 Electric Clothes Dryer Model RDE350AW ...

Страница 3: ...he time for setting 30 min 60 min 90 min 120 min User s manual product registration card Rated voltage rated frequency Rated dry capacity Rated power consumption in drying Rated input consumption of motor Manual setting Automatic Accessories Dimension Weight kg 4800W 379W 1 Specification List 1 2 Dimensional Drawing 686 718 1080 Unit mm Electric Clothes Dryer Model RDE350AW ...

Страница 4: ... front door control panel shutter exhaust duct back baffle nameplate cabinet adjustable foot thread protected board I thread protected board II fasten button whisk leaf barrel roll lint filter lock body Electric Clothes Dryer Model RDE350AW RELAY 4 Names of parts ...

Страница 5: ... Clothes Dryer Model RDE350AW Normal drying Heavy weight material such as jeans or bath towlels Heavy Duty Normal Delicate Drying small quantity clothes and delicate fabric Press the button to turn the dryer ON Press this button once to start the dry process Press this button again to pause the activity during the dry cycle This indicates the process the cycle is currently in At the end of the dry...

Страница 6: ...e and exhaust system has high degree of tightness and improves the thermal efficiency 5 Heating system The electric heating thread installed on the heating plate at the rear of the cabinet is the heating source of the appliance The exchanging of cold and hot air is realized by it The heating power of the electric heating thread is about 4700W It can raise the air temperature rapidly and offer hot ...

Страница 7: ...as four leveling legs which are located in the front and rear corners of your dryer After properly placing your dryer or by turning them counterclockwise to lower your dryer Leveling legs can be adjusted by turning them clockwise to raise your dryer or by turning them counter clockwise to lower your dryer 6 Lint filter It is a kind of wearing part made of filter screen frame and screen cloth by on...

Страница 8: ...egs located on the bottom of the dryer 1 remove all packaging material This includes the foam base and all adhensive tape holding the dryer acessories inside and outside 2 inspect and remove any remains of packing tape or printed material before using the dryer 7 Key points in installation adjustment and disassembly C C C Tools and materials required Electrical requirements Unpacking your dryer Ma...

Страница 9: ...he rigid metal duct work should be used 2 Venting vertical through a roof may expose the exhaust system to down drafts causing an increase in vent restriction 3 Running the exhaust system through an uninsulated area may cause condensation and faster accumulation of lint 4 Compression or crimping of the exhaust system will cause an increase in vent restriction C C Location of your dryer Rough in di...

Страница 10: ...DO DON T Correct Incorrect Correct DO DON T Incorrect C C Requirements and instructions Electrical connections 1 This appliance MUST be properly grounded Electrical shock can result if the dryer is not properly grounded Follow the instructions in this manual for proper grounding 3 A U L approved strain relief must be installed onto power cord If the strain relief is not attached the cord can be pu...

Страница 11: ...ief nut securely so that the tension relief does not turn 9 Reinstall the terminal block cover Grounding instruction This appliances must be connected to a ground metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the appliance nut tighten nut to these threads power cord strain relie...

Страница 12: ...e sequencer plug inserts correctly Check if the control thermostat and high limit thermostat act Replace the control thermostat and high limit thermostat Measure the resistance of the heater Replace the heater The heater is off The resistance is infinite Yes Check the ventilation condition Check if the vent pipe and the vent way is blocked No ventilating No No No Yes Yes Yes Check if the wire unit...

Страница 13: ...te Pull the power Yes Check and replace the power down lead Check and replace the computer program panel Check if the computer program panel is on Push down the searching unit and check if the door switch is on Check if the control thermostat and high limit thermostat are good Check if the heater is good Check if the motor is good Check if the wire unit is good while pushing down the start button ...

Страница 14: ...the cabinet and the cabinet or the abrasion between the support wheel and the bracket of support wheel Yes Yes Yes Yes No No No Fasten the support bracket or replace the support wheel Check the tensive condition replace the tensive spring Fasten the heating ring and the fasten screw Adjust or replace the worm shell If there is a noise from the tensive spring If there is metallic bangs because the ...

Страница 15: ...Group Sincere Forever Haier Industrial Park No 1 Haier Road 266101 Qingdao China http www haier com ...