background image

MRV II

Aug. 2008

Design Manual

R410A HEAT PUMP 50HZ

SYJS-001-08REV.0

AV08NMVERA

AV10NMVERA

AV12NMVERA

AV14NMVERA

AV16NMVERA

AV18NMVERA

AV20NMVERA

AV22NMVERA

AV24NMVERA

AV26NMVERA

AV28NMVERA

AV28NMVERA

AV30NMVERA

AV32NMVERA

AV34NMVERA

AV36NMVERA

AV38NMVERA

AV40NMVERA

AV42NMVERA

AV44NMVERA

AV46NMVERA

AV48NMVERA

Summary of Contents for MRV II AV08NMVERA

Page 1: ...S 001 08REV 0 AV08NMVERA AV10NMVERA AV12NMVERA AV14NMVERA AV16NMVERA AV18NMVERA AV20NMVERA AV22NMVERA AV24NMVERA AV26NMVERA AV28NMVERA AV28NMVERA AV30NMVERA AV32NMVERA AV34NMVERA AV36NMVERA AV38NMVERA AV40NMVERA AV42NMVERA AV44NMVERA AV46NMVERA AV48NMVERA ...

Page 2: ...lanation 4 Capacity range 5 Features 6 Control system 7 Specifications 8 Dimensions 9 Air flow and static pressure curves 10 Capacity calculation due to capacity modification coefficient 11 Refrigerant piping design 12 Wiring design 13 Management system H CACS 03 06 07 08 09 13 16 42 74 84 89 101 110 ...

Page 3: ...182 242 382 482 162 Wall mounted type AS MC AERA 072 092 122 162 182 282 302 382 Console type AF MAERA 072 092 122 Outdoor units Type AV MVERA Model 10HP 10N 12HP 12N 14HP 14N 16HP 16N 18HP 18N 20HP 20N 22HP 22N 24HP 24N 03 8HP 08N 28HP 28N 30HP 30N 482 092 122 Type AV MVERA Model 34HP 34N 36HP 36N 38HP 38N 40HP 40N 42HP 42N 44HP 44N 46HP 46N 48HP 48N 32HP 32N 722 962 AB MCERA 182 242 282 302 382 ...

Page 4: ...G R U P A d o o AV08NMVERA 1 2 External appearance Outdoor AV16NMVERA AV18 20NMVERA AV22 24 26NMVERA AV28 30 32NMVERA AV34 36NMVERA AV38 40 42NMVERA AV44 46 48NMVERA 04 AV10NMVERA AV14NMVERA AV12NMVERA ...

Page 5: ...IGH ESP DUCT TYPE AD182MHERA AD242MHERA AD282MHERA AD302MHERA AD382MHERA AD482MHERA CONSOLE TYPE AC092MCERA AC122MCERA AC162MCERA AC182MCERA AC242MCERA CONVERTIBLE TYPE AC382MFERA AC482MFERA HRV heat reclaimed ventilation ERV0150ANN ERV0200ANN ERV0260ANN ERV0350ANN ERV0800ANN ERV1000ANN ERV1200ANN ERV1500ANN WALL MOUNTED TYPE AB182MCERA AB242MCERA AB282MCERA AB302MCERA AB382MCERA AB482MCERA 4 WAY ...

Page 6: ...0 1235 1300 1350 HP 08 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 1 0 0 0 0 0 1 0 0 0 0 0 1 0 0 0 0 0 1 0 0 0 0 0 1 1 1 0 0 0 0 2 0 0 0 0 1 1 0 0 0 1 0 1 0 0 1 0 0 1 0 0 0 2 0 0 0 0 1 1 0 0 0 0 2 0 2 0 1 0 0 2 0 0 1 0 1 0 2 0 0 1 0 1 1 0 1 0 0 2 0 0 1 0 2 0 0 0 1 2 0 0 0 0 3 Total QTY AV16 AV10 AV12 AV14 1 1 1 1 1 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 ...

Page 7: ...s for MRVII R410A outdoor Climate type T1 Haier Air Conditioner Indoor unit Model A B 09 2 M C E R A Design number A stands for fixed frequency type H stands for inverter type R stands for DC inverter and R410A type Cooling or heating and refrigerant E stands for heat pump type refrigerant is R410a Appearance character Product series M stands for MRV II R410A Applicable voltage 2 stands for 220 23...

Page 8: ...otal indoor capacity range 100W 16HP 20HP 24HP 30HP 16 26 33 39 50 140 364 226 588 280 728 340 884 425 1105 Indoor unit outdoor capacity 34HP 36HP 38HP 56 59 63 480 1248 505 1313 540 1404 8HP 13 113 294 12HP 19 168 436 14HP 23 200 520 18HP 29 253 658 22HP 36 308 800 26HP 43 365 949 28HP 46 400 1040 32HP 53 450 1170 40HP 46HP 64 565 1469 650 1690 outdoor capacity 48HP 675 1755 42HP 590 1534 44HP 61...

Page 9: ...r And the built in part is made of Aluminum The large blade fan is running stably and silently 5 3 High efficiency DC fan motor The DC fan motor is high efficiency and low noise Stable operation and reliable performance 5 4 Intelligent electric control with heat expelling fan to reduce the electric control box temperature and keep the electric safe Compressor shall be equipped with the inverter co...

Page 10: ... unit evenly to ensure the effect of every indoor unit is normal Thoroughly prevent the gas refrigerant flowing into indoor installed at higher place because of the instant evaporation 5 6 Flexible installation and design Indoor quantity can be up to 64 sets in maximum And the indoor total capacity can be 50 130 of outdoor capacity If there are multiple outdoors the outdoors will be in running by ...

Page 11: ...VII has been designed to get high COP from the reasonable structure and the excellent electric system b Approved for RoHS certificate All the parts in the unit have been approved for RoHS certificate The parts are in conformance with RoHS directive Thus Haier MRVII will be environmental for human and nature The directive is to approximate the laws of the Member States on the restrictions of the us...

Page 12: ...the protection when temperature current etc occur error The compressor will help the unit run normally 5 12 Multiple indoor types There are multiple indoor types to meet the variable request The outdoor can be suitable for mix match connection of following indoor types Cassette type Convertible type Ceiling concealed type Med static pressure duct type High static pressure duct type Wall mounted ty...

Page 13: ... XIQT42 XMQIV cra4 8 3fmsp rgkcp dslargml rm qcr rfc qafcbsjc gl _ ufmjc b_w Hcqgelcb rm afcai rfc qwqrck d_gjspc _srmk_rga_jjw w npcqqgle GLIGO srrml4 Ejqm rfc d_gjspc ambc ugjj bgqnj_w ml PGH fcl rfc dgjrcp lccbq rm c ajc_lcb _lb glbmmp ugjj qclb qgel_j rm rfc amlrpmjjcp2 JMPXIV gaml ugjj bgqnj_w ml PGH4 G_l bgqnj_w rfc glbmmp aclrp_j _bbpcqq ml PGH G_l oscpw rfc k_jdslargml fgqrmpw w npcqqgle G...

Page 14: ...er Realize to control 16 indoor units ON OFF synchronously Set indoor units at the same mode Note When the indoor unit is in group control it CAN NOT be controlled by its individual controller wired cotroller or infrared controller Indoor unit Power Group controller ...

Page 15: ...xternal signal such as the fire alarm make the interconnect control Receive the external timing signal to make TIMER ON OFF control Indoor unit Unit No 1 Wired controller group control Connection board IGU04 Outdoor unit master unit Unit No 62 Unit No 63 Unit No 64 Central controller 1 64 Indoor unit Indoor unit Indoor unit Outdoor unit master unit Outdoor unit master unit Outdoor unit master unit...

Page 16: ...centrifugal 1 0 04 700 0 660 570 260 700 700 60 19 21 6 2 8 4 8 3 6 4 0 3 2 1 220 230 50 0 47 0 08 centrifugal 1 0 04 700 0 660 570 260 700 700 60 19 21 6 2 8 4 8 4 5 5 0 4 0 1 220 230 50 0 47 0 08 centrifugal 1 0 04 700 0 660 570 260 700 700 60 19 21 6 2 8 4 8 33 30 29 12 7 6 35 32 Weight unit net gross Kg Weight panel net gross Kg 34 32 30 AB182MEERA 12 7 6 35 32 5 6 6 3 2 1 9 55 5 0 1 220 230 5...

Page 17: ...50 80 30 36 6 9 9 0 10 0 2 7 12 3 8 0 1 220 230 50 0 76 0 15 centrifugal 1 0 14 1920 0 840 840 295 950 950 80 38 44 6 9 14 0 16 0 2 7 12 3 12 5 1 220 230 50 0 76 0 15 centrifugal 1 0 14 1920 0 840 840 295 950 950 80 38 44 6 9 42 39 35 32 15 88 9 52 15 88 9 52 Weight panel net gross Kg AB282MEERA 8 0 9 0 2 1 9 55 7 1 1 220 230 50 0 47 0 08 centrifugal 1 0 04 1020 0 840 840 240 950 950 80 30 36 6 9 ...

Page 18: ...fugal 1 0 05 1200 0 840 840 240 950 950 80 30 36 6 9 7 1 8 6 1 220 230 50 0 51 0 1 centrifugal 1 0 05 1200 0 840 840 240 950 950 80 30 36 6 9 8 9 7 0 1 220 230 50 0 51 0 1 centrifugal 1 0 05 1200 0 840 840 240 950 950 80 30 36 6 9 37 35 31 32 Weight unit net gross Kg Weight panel net gross Kg AB302MCERA 32 9 10 8 0 1 220 230 50 0 76 0 15 centrifugal 1 0 09 1800 0 840 840 280 950 950 80 30 36 6 9 N...

Page 19: ...pe and Qty Fan motor output KW Weight unit net gross Kg Weight panel net gross Kg AB482MCERA 32 14 16 12 5 1 220 230 50 0 76 0 15 centrifugal 1 0 09 1800 0 840 840 280 950 950 80 38 40 6 9 Norminal condition indoor temperature cooling 270 CDB 190 CWB indoor temperature heating 200 CDB 14 50 CWB Outdoor temperature cooling 350 CDB 240 CWB outdoor temperature heating 70 CDB 60 CWB The noise level wi...

Page 20: ...oller optional 6 35 35 32 30 35 32 30 12 7 6 35 6 35 24 20 AD072MLERA AD092MLERA AD122MLERA Model Nominal heating capacity KW Nominal cooling capacity KW 35 32 30 Fan characteristic Heating capacity at low temp KW 2 0 2 5 3 2 Fan type centrifugal 1 Fan motor output KW 0 012 0 012 0 02 20 0 20 0 610 483 5 220 610 483 5 220 418 131 418 131 13 13 5 14 14 5 9 52 20 0 Air return dimensions mm 480 218 4...

Page 21: ...eturn dimensions mm 4 5 5 6 7 1 5 0 6 3 8 0 0 27 0 55 0 55 0 05 0 11 0 11 850 1250 1250 0 20 1 8 8 2 880 131 25 26 15 88 36 33 31 39 37 35 12 7 6 35 9 52 AD162MLERA AD182MLERA AD242MLERA 4 0 5 0 centrifugal 2 1 8 8 2 1 8 8 2 6 3 0 04 0 04 0 0 20 20 1105 483 5 220 1105 483 5 220 1105 483 5 220 880 131 880 131 1064 218 1064 218 1064 218 28 29 28 29 36 33 31 12 7 6 35 Norminal condition indoor temper...

Page 22: ...ntroller Noise level dB A H M L Drain hose mm Fan chara cteris tics Wired controller wireless controller optional Air outlet dimensions mm Model 1200 Heating capacity at low temp KW 5 0 6 3 7 1 Fan type and Qty Fan motor output KW centrifugal 3 centrifugal 3 centrifugal 3 0 15 Norminal condition indoor temperature cooling 270 CDB 190 CWB indoor temperature heating 200 CDB 14 50 CWB Outdoor tempera...

Page 23: ...nt A Powerconsumption KW Weight Kg Gas piping mm Liquid piping mm Controller Noise level dB A H M L Drain hose mm Fan chara cteris tics Wired controller wireless controller optional Air outlet dimensions mm Model 1900 Heating capacity at low temp KW 8 0 10 0 12 5 Fan type and Qty Fan motor output KW centrifugal 3 centrifugal 3 centrifugal 3 0 15 Norminal condition indoor temperature cooling 270 CD...

Page 24: ...Qty Fan motor output KW AD182MHERA AD242MHERA 5 6 6 3 2 6 11 9 5 0 1 4 0 28 centrifugal 2 0 23 900 1500 100 196 970 875 360 600 250 48 56 7 1 8 2 6 11 9 6 3 1 4 0 28 centrifugal 2 0 23 900 1500 100 196 970 875 360 600 250 48 56 8 9 2 6 11 9 7 1 1 4 0 28 centrifugal 2 0 23 900 1500 100 196 970 875 360 600 250 48 56 12 7 6 35 32 42 40 15 88 9 52 32 42 40 15 88 9 52 32 42 40 Norminal condition indoor...

Page 25: ...ons mm Model Heating capacity at low temp KW Fan type and Qty Fan motor output KW AD302MHERA AD382MHERA 9 0 10 0 8 0 1 5 0 3 centrifugal 2 0 27 1560 100 196 1350 875 360 850 250 62 77 11 2 12 5 10 0 1 6 0 32 centrifugal 2 0 27 1600 100 196 1350 875 360 850 250 62 77 14 0 16 0 12 5 1 8 0 36 centrifugal 2 0 27 2100 100 196 1350 875 360 850 250 62 77 15 88 9 52 32 45 40 15 88 9 52 32 45 40 15 88 9 52...

Page 26: ...Nominal heating capacity KW Electri cal chara cteris tics Electrical heating power KW Current A Power source Standard airflow m3 h Standard static pressure Pa Max static pressure Pa Exterior dimensions mm Piping dimension Operating current A Powerconsumption KW Weight net gross Kg Gas piping mm Liquid piping mm Controller Noise level dB A H L Drain hose mm Fan chara cteris tics Wired controller wi...

Page 27: ...l chara cteris tics Electrical heating power KW Current A Power source Standard airflow m3 h Standard static pressure Pa Max static pressure Pa Exterior dimensions mm Piping dimension Operating current A Powerconsumption KW Weight Kg Gas piping mm Liquid piping mm Controller Noise level dB A H M L Drain hose mm Fan chara cteris tics Wired controller wireless controller optional Air outlet dimensio...

Page 28: ...er optional Air outlet dimensions mm Model Heating capacity at low temp KW Fan type and Qty Fan motor output KW centrifugal 4 8 0 5 0 1 0 09 1580 700 240 54 61 25 1800 AC482MFERA 53 51 49 14 16 centrifugal 4 10 0 5 0 1 0 09 1580 700 240 54 61 Norminal condition indoor temperature cooling 270 CDB 190 CWB indoor temperature heating 200 CDB 14 50 CWB Outdoor temperature cooling 350 CDB 240 CWB outdoo...

Page 29: ...utlet dimensions mm 1PH 220 230V 50Hz 12 7 6 35 16 5 AS072MCERA AS092MCERA AS122MCERA Nominal cooling capacity KW Nominal heating capacity KW Electri cal chara cteris tics Power source Standard airflow m3 h Standard static pressure Pa Max static pressure Pa Exterior dimensions mm Piping dimension Operating current A Powerconsumption KW Weight Kg Gas piping mm Liquid piping mm Controller Noise leve...

Page 30: ... 886y896Z2 6Lx 784 49 7 4 EJ6 8QEIVE EJ6 8QEIVE EJ788QEIVE Rmkgl_j ammjgle a_n_agrw O Rmkgl_j fc_rgle a_n_agrw O Ijcarpg3 a_j af_p_3 arcpgq3 rgaq Tmucp qmspac Wr_lb_pb _gpdjmu k9 5f Wr_lb_pb qr_rga npcqqspc T_ Q_v4 qr_rga npcqqspc T_ Ivrcpgmp bgkclqgmlq kk Tgngle bgkclqgml Sncp_rgle asppclr E Tmucpamlqsknrgml O cgefr Oe K_q ngngle kk Pgosgb ngngle kk Gmlrpmjjcp Rmgqc jctcj bF E L5Q5P Hp_gl fmqc kk...

Page 31: ...eating Electrical characteristics Power consumption when heating at low temp kw Exterior dimensions mm Weight Kg Exterior colour Compressor type Outdoor airflow m3 h Refrigerant R410A charge Kg Gas piping mm Liquid piping mm Equipoise Oilequalizationpiping mm Piping dimension 10 AV10NMVERA 28 0 31 5 25 6 12 2 15 6 7 36 9 45 13 2 15 8 7 97 10 2 6 73 3N 380 400V 50Hz 0 7 990 750 1750 235 ivory scrol...

Page 32: ...ting Electrical characteristics Power consumption when heating at low temp kw Exterior dimensions mm Weight Kg Exterior colour Compressor type Outdoor airflow m3 h Refrigerant R410A charge Kg Gas piping mm Liquid piping mm Equipoise Oilequalizationpiping mm Piping dimension 12 AV12NMVERA 33 5 37 5 28 7 14 2 17 0 8 58 10 3 15 1 18 4 9 1 11 3 7 55 3N 380 400V 50Hz 1 1 1390 750 1750 275 ivory scroll ...

Page 33: ...ax consumption kw Cooling Operating Max current A Operating Max consumption kw Heating Electrical characteristics Power consumption when heating at low temp kw Exterior dimensions mm Weight Kg Exterior colour Compressor type Outdoor airflow m3 h Refrigerant R410A charge Kg Gas piping mm Liquid piping mm Equipoise Oilequalizationpiping mm Piping dimension 3N 380 400V 50Hz 16 AV16NMVERA 45 0 50 0 39...

Page 34: ...g Electrical characteristics Power consumption when heating at low temp kw Exterior dimensions mm Weight Kg Exterior colour Compressor type Outdoor airflow m3 h Refrigerant R410A charge Kg Gas piping mm Liquid piping mm Equipoise Oilequalizationpiping mm Piping dimension 3N 380 400V 50Hz 18 AV18NMVERA AV08 AV10 50 6 56 5 46 8 20 9 26 1 12 64 15 79 22 9 27 1 13 86 17 05 12 3 1 4 990 750 1750 990 75...

Page 35: ... dimensions mm Weight Kg Exterior colour Compressor model Outdoor airflow m3 h Refrigerant R410a charge Kg Gas piping mm Liquid piping mm Piping dimension Output power of outdoor motor KW Equipoise Oilequalizationpiping mm AV10 AV12 AV10 AV14 28 58 15 88 Norminal condition indoor temperature cooling 270 CDB 190 CWB indoor temperature heating 200 CDB 14 50 CWB Outdoor temperature cooling 350 CDB 24...

Page 36: ...ting Electrical characteristics Power consumption when heating at low temp kw Exterior dimensions mm Weight Kg Exterior colour Compressor type Outdoor airflow m3 h Refrigerant R410A charge Kg Gas piping mm Liquid piping mm Equipoise Oilequalizationpiping mm Piping dimension 3N 380 400V 50Hz 28 AV28NMVERA AV14 AV14 80 90 73 4 40 6 48 8 24 62 29 6 38 6 46 4 23 38 28 2 19 3 2 2 1390 750 1750 1390 750...

Page 37: ...ting Electrical characteristics Power consumption when heating at low temp kw Exterior dimensions mm Weight Kg Exterior colour Compressor type Outdoor airflow m3 h Refrigerant R410A charge Kg Gas piping mm Liquid piping mm Equipoise Oilequalizationpiping mm Piping dimension 3N 380 400V 50Hz 30 AV30NMVERA AV14 AV16 85 95 75 8 43 5 52 5 26 37 31 8 40 5 48 8 24 51 29 48 19 93 2 2 1390 750 1750 1390 7...

Page 38: ...imensions mm Weight Kg Exterior colour Compressor model Outdoor airflow m3 h Refrigerant R410a charge Kg Gas piping mm Liquid piping mm Piping dimension Output power of outdoor motor KW Equipoise Oilequalizationpiping mm AV10 AV10 AV14 AV10 AV10 AV16 38 1 19 05 Norminal condition indoor temperature cooling 270 CDB 190 CWB indoor temperature heating 200 CDB 14 50 CWB Outdoor temperature cooling 350...

Page 39: ...rical characteristics Power consumption when heating at low temp kw Exterior dimensions mm Weight Kg Exterior colour Compressor type Outdoor airflow m3 h Refrigerant R410A charge Kg Gas piping mm Liquid piping mm Equipoise Oilequalizationpiping mm Piping dimension 3N 380 400V 50Hz 38 AV38NMVERA AV10 AV14 AV14 108 121 5 99 52 8 64 4 31 98 39 05 51 8 62 2 31 35 38 4 24 75 2 9 990 750 1750 1390 750 1...

Page 40: ...or KW Equipoise Oilequalizationpiping mm AV12 AV16 AV16 Norminal condition indoor temperature cooling 270 CDB 190 CWB indoor temperature heating 200 CDB 14 50 CWB Outdoor temperature cooling 350 CDB 240 CWB outdoor temperature heating 70 CDB 60 CWB The noise level will be measured in the third octave band limited values in the semi anechoic chamber using a Real Time Analyser calibrated sound inten...

Page 41: ...mension Output power of outdoor motor KW Gas piping mm Liquid piping mm Equipoise Oilequalizationpiping mm 9 52 38 1 19 05 38 1 19 05 AV16 AV16 AV16 135 150 117 3 69 6 84 3 42 18 51 63 6 76 8 38 46 46 14 30 84 3 3 1390 750 1750 3 900 36000 48 Norminal condition indoor temperature cooling 270 CDB 190 CWB indoor temperature heating 200 CDB 14 50 CWB Outdoor temperature cooling 350 CDB 240 CWB outdoo...

Page 42: ...0mm ceiling opening dimension 700mm panel dimension 570mm indoor unit dimension 650mm ceiling opening dimension 700mm panel dimension VIEW A 95 140 180 fresh air hole suspension holder 320mm 150mm 60mm overlaped distance between the ceiling and the panel 25mm ceiling panel 57 75 65 80 100 145 AB092MCERA AB122MCERA AB162MCERA Cassette type indoor ...

Page 43: ...43 950 950 840 295 240 180 50 30 20 135 160 260 860 890 ceiling hole 680 hang position 860 890 680 mm 260 270 315 140 200 80 30 180 57 155 35 57 85 85 345 103 35 106 air discharge hole AB182MEERA AB242MEERA AB282MEERA ...

Page 44: ...o 44 950 950 840 295 290 220 50 30 135 160 310 860 890 ceiling hole 680 hang position 860 890 680 mm 260 270 315 140 200 80 30 220 57 155 35 57 85 85 345 103 35 106 air discharge hole AB302MEERA AB382MEERA AB482MEERA ...

Page 45: ...45 AB182MCERA AB242MCERA AB282MCERA 950 950 840 295 240 180 50 30 20 135 160 260 860 890 ceiling hole 680 hang position 860 890 680 mm 260 270 315 140 200 80 30 180 57 155 35 57 85 85 345 103 35 106 air discharge hole ...

Page 46: ...o 46 AB302MCERA AB382MCERA AB482MCERA 950 950 840 295 290 220 50 30 135 160 310 860 890 ceiling hole 680 hang position 860 890 680 260 270 315 140 200 80 30 220 57 155 35 57 85 85 345 103 35 106 air discharge hole mm ...

Page 47: ...8 483 5 418 1002 483 131 220 1105 255 131 970 610 880 508 105 h 220 AD07 122MLERA AD16 242MLERA 255 J 24 24 Ceiling concealed type indoor DG7 899POHUD Hvaporators of DG7 3 DG7 are 94row typeB evaporator of DG89 is 4row type5 7 877 89 9 7 8 7 997 ...

Page 48: ...G R U P A d o o 48 AD16 242MLERA Evaporators of AD16 18 are 2 row type evaporator of AD24 is 3 row type 7 877 9 7 89 8 7 7 997 ...

Page 49: ...ERA AD242MMERA AD282MMERA 130 200 170 890 200 200 260 275 A 35 10 300 R100 85 70 20 545 635 960 986 890 A A gas pipe liquid pipe drainage pipe 235 165 120 100 150 265 mm 30 210 80 270 305 32 Med static pressure duct type indoor ...

Page 50: ...d o o 50 AD302MMERA AD382MMERA AD482MMERA 260 275 35 350 R100 85 260 275 A A gas pipe liquid pipe drainage pipe 235 165 120 100 150 265 85 545 655 1370 1406 240 1280 mm 210 105 275 68 70 electric control box A 32 ...

Page 51: ...G R U P A d o o 51 AD182MHERA AD242MHERA AD282MHERA 800 960 15 100 145 345 80 830 electric control box 210 290 30 32 185 60 250 750 30 840 170 205 130 120 365 mm High static pressure duct type indoor ...

Page 52: ...G R U P A d o o 52 800 1320 1200 170 270 250 365 250 60 45 1105 mm 15 100 145 345 80 185 AD302MHERA AD382MHERA AD482MHERA 830 electric control box 210 290 30 32 ...

Page 53: ...Gas pipe Liquid pipe 830 794 18 25 18 1570 1690 100 25 80 95 60 1640 60 12 7 1 2 28 58 1 1 8 Air inlet 65 13 138 250 13 138 13 163 35 6x200 1200 1500 200 M5x20pcs 13 163 35 mm Air outlet M10x4pcs M5x20pcs 138 13 13 138 60 138 250 77 13 200 6X200 1200 1450 60 138 13 45 25 49 DRAIN PIPE VP25 25 510 80 30 310 360 106 25 170 185 530 A 205 245 AD722MHERA AD962MHERA ...

Page 54: ...54 AC092MCERA AC122MCERA AC162MCERA AC182MCERA AC242MCERA mm 100 100 20 10 620 605 600 40 35 35 30 199 655 240 100 900 990 200 880 back plate bottom plate right side 100 100 30 30 100 100 30 25 Convertible type indoor ...

Page 55: ...G R U P A d o o 55 AC382MFERA AC482MFERA 1580 700 285 598 495 570 640 240 90 55 36 114 200 95 150 47 440 40 300 60 25 47 47 47 155 90 200 50 224 47 47 47 47 200 30 130 ...

Page 56: ...G R U P A d o o 56 Wall mounted type indoor right side 200 60 50 55 left side 50 55 200 60 70 60 45 bottom side model a b c AS072 092 122MCERA 795 265 182 AS162 182MCERA 928 AS242MAERA a b c Haier ...

Page 57: ...und outdoor should be less than 800mm to the bottom of unit 8 10HP More than 100mm Top side More than 100mm 500mm 1550mm Oil pipe Liquid pipe Gas pipe 2 60 150 245 500 88 700 1560 1750 700 630 100 100 755 Gas pipe Liquid pipe Oil pipe 4 15 20 700 750 790 990 80 190 235 90 300mm 138 168 62 125 143 65 55 125 92 173 80 Console type indoor ...

Page 58: ...G R U P A d o o 58 12 14 16HP 1390 100 100 80 630 755 80 700 700 over 100 front 500 750 790 over 100 1750 1560 700 88 90 over 300 over 500 over 1550 ...

Page 59: ...stance between two outdoor units in the same line and the distance from unit to the wall can be increased for easy maintenance if there is enough space D The sequence and the position of every outdoor can be at will 18 20HP Combined outdoor unit over 100 front over 100 over 200 over 2380 over 300 over 500 over 1550 over 200 700 700 990 990 750 790 1750 1560 700 over 2180 88 90 ...

Page 60: ... A There should be no obstacles in 2000mm above the top of outdoor unit B Obstacles around outdoor should be less than 800mm to the bottom of unit C The distance between two outdoor units in the same line and the distance from unit to the wall can be increased for easy maintenance if there is enough space D The sequence and the position of every outdoor can be at will ...

Page 61: ...e A There should be no obstacles in 2000mm above the top of outdoor unit B Obstacles around outdoor should be less than 800mm to the bottom of unit C The distance between two outdoor units in the same line and the distance from unit to the wall can be increased for easy maintenance if there is enough space D The sequence and the position of every outdoor can be at will ...

Page 62: ...er 3770 Note A There should be no obstacles in 2000mm above the top of outdoor unit B Obstacles around outdoor should be less than 800mm to the bottom of unit C The distance between two outdoor units in the same line and the distance from unit to the wall can be increased for easy maintenance if there is enough space D The sequence and the position of every outdoor can be at will ...

Page 63: ...over 4170 Note A There should be no obstacles in 2000mm above the top of outdoor unit B Obstacles around outdoor should be less than 800mm to the bottom of unit C The distance between two outdoor units in the same line and the distance from unit to the wall can be increased for easy maintenance if there is enough space D The sequence and the position of every outdoor can be at will ...

Page 64: ...550 front Note A There should be no obstacles in 2000mm above the top of outdoor unit B Obstacles around outdoor should be less than 800mm to the bottom of unit C The distance between two outdoor units in the same line and the distance from unit to the wall can be increased for easy maintenance if there is enough space D The sequence and the position of every outdoor can be at will ...

Page 65: ... A Sites for one row layout The distance between two outdoor units in the same line and the distance from unit to the wall can be increased for easy maintenance if there is enough space More than 300mm Front side More than 200mm More than 200mm More than 100mm More than 500mm Less than 800mm ...

Page 66: ...wo outdoor units in the same line and the distance from unit to the wall can be increased for easy maintenance if there is enough space More than 300mm Front side More than 200mm More than 200mm More than 100mm More than 600mm More than 300mm Front side Less than 800mm ...

Page 67: ...nits in the same line and the distance from unit to the wall can be increased for easy maintenance if there is enough space More than 300mm Front side More than 200mm More than 200mm More than 100mm More than 500mm More than 600mm Front side More than 600mm Front side Less than 800mm ...

Page 68: ... A Place with air inlet hole Notes 1 Fan speed Vs at air inlet is 1 5m s or below 2 Air outlet height HD H h and below 1m 2 Wall higher than the outdoor unit Front side Above 100mm Above 600mm Above 300mm Above 200mm Above 200mm Above 1000mm air outlet h HD H Vs ...

Page 69: ...d o o 69 B Place without air inlet hole Notes A Set a 500 1000mm bracket B Air outlet height HD H h and below 1m 500 1000mm air outlet H h HD Front side Above 100mm Above 600mm Above 300mm Above 200mm Above 200mm ...

Page 70: ...7 55 OD6 35 ID9 7 104 OD15 88 ID9 7 ID12 9 104 OD15 88 ID9 7 ID12 9 100 ID9 7 OD12 7 323 ID28 8 OD22 2 ID25 6 OD25 4 ID25 6 ID28 8 OD22 22 1 5 ID16 1 ID22 4 ID19 3 ID12 9 55 OD6 35 ID9 7 180 OD28 58 ID25 6 ID22 4 ID19 3 ID16 1 ID12 9 100 ID9 7 OD12 7 238 ID9 7 ID9 7 ID6 5 OD12 7 ID12 9 ID12 9 ID12 9 55 OD6 35 ID9 7 388 ID9 7 ID9 7 ID6 5 OD25 4 ID12 9 ID12 9 ID16 1 OD19 05 ID16 1 OD1 9 05 ID16 1 32...

Page 71: ... ID9 7 OD25 4 OD1 9 05 ID16 1 ID12 9 ID16 1 ID19 3 ID22 4 ID22 4 ID19 3 ID12 9 ID9 7 ID6 5 366 ID38 3 OD31 75 OD28 6 ID32 OD31 75 ID32 ID38 3 ID28 8 100 ID9 7 OD12 7 180 OD28 58 ID25 6 ID22 4 ID19 3 ID16 1 ID12 9 140 OD31 75 ID28 8 ID25 6 ID22 4 138 OD22 22 ID16 1 ID12 9 ID19 3 ...

Page 72: ... 0 1 0 25 0 1 0 25 0 1 ID9 52 0 25 0 1 40 40 40 10 424 94 5 0 25 0 1 40 0 25 0 1 40 40 10 0 25 0 1 ID25 4 0 2 0 05 ID22 22 0 2 0 05 ID19 1 0 2 0 05 200 40 40 12 Double 120 14 ID35 1 0 2 0 05 120 14 ID38 1 0 2 0 05 ID38 1 0 2 0 05 30 ID38 1 0 25 0 1 550 667 12 ID28 6 0 2 0 05 15 189 ID12 7 0 25 0 1 ID12 7 0 25 0 1 Double ID28 6 0 2 0 05 ID25 4 0 2 0 05 ID22 22 0 2 0 05 ID19 1 0 2 0 05 465 640 15 0 ...

Page 73: ... 1 17 33 49 2 18 34 50 3 19 35 51 4 20 36 52 5 21 37 53 6 22 38 54 7 23 39 55 8 24 40 56 9 25 41 57 10 26 42 58 11 27 43 59 12 28 44 60 13 29 45 61 14 30 46 62 15 31 47 63 16 32 48 64 MONITOR SET MODE FAN COOL DRY HEAT AUTO 1 2 GROUP TOTAL UNIT RUN STOP CENTRAL LOCK SLAVE TIMER STANDBY FILTER FAN SPEED AUTO HIGH MID LOW SET FAILURE CHECK RECOVERY SWING AUTO NORMAL HRV central controller ICR01 IGU0...

Page 74: ...curves 150 200 250 300 350 400 450 500 550 0 10 20 static pressure Pa air flow m3 h super high high med low AD092MLERA air flow and static pressure curves 150 200 250 300 350 400 450 500 550 0 10 20 static pressure Pa air flow m3 h super high high med low 9 Air flow and static pressure curves 74 ...

Page 75: ... curves 250 300 350 400 450 500 550 600 650 0 10 20 static pressure Pa air flow m3 h super high high med low AD162MLERA air flow and static pressure curves 600 650 700 750 800 850 900 950 1000 0 10 20 static pressure Pa air flow m3 h super high high med low 75 ...

Page 76: ...000 1050 1100 1150 1200 1250 1300 1350 1400 0 10 20 static pressure Pa air flow m3 h super high high med low AD242MLERA air flow and static pressure curves 1000 1050 1100 1150 1200 1250 1300 1350 1400 0 10 20 static pressure Pa air flow m3 h super high high med low 76 ...

Page 77: ...00 1000 1100 1200 1300 1400 40 50 60 70 80 90 100 static pressure Pa air flow m 3 h super high high med low AD242MMERA air flow and static pressure curves 800 900 1000 1100 1200 1300 1400 40 50 60 70 80 90 100 static pressure Pa air flow m h super high high med low 3 77 ...

Page 78: ...00 1300 1400 1500 1600 1700 40 50 60 70 80 90 100 static pressure Pa air flow m h super high high med low AD302MMERA air flow and static pressure curves 1700 1800 1900 2000 2100 2200 2300 40 50 60 70 80 90 100 static pressure Pa air flow m h super high high med low 3 3 78 ...

Page 79: ...00 1900 2000 2100 2200 2300 40 50 60 70 80 90 100 static pressure Pa air flow m h super high high med low AD482MMERA air flow and static pressure curves 1700 1800 1900 2000 2100 2200 2300 40 50 60 70 80 90 100 static pressure Pa air flow m h super high high med low 3 3 79 ...

Page 80: ...e curves 0 200 400 600 800 1000 1200 1400 80 100 120 140 160 180 200 static pressure Pa air flow m 3 h super high high med low AD242MHERA air flow and static pressure curves 0 200 400 600 800 1000 1200 1400 80 100 120 140 160 180 200 static pressure Pa air flow m h super high high med low 3 80 ...

Page 81: ...00 800 1000 1200 1400 80 100 120 140 160 180 200 static pressure Pa air flow m h super high high med low AD302MHERA air flow and static pressure curves 800 1000 1200 1400 1600 1800 2000 80 100 120 140 160 180 200 static pressure Pa air flow m h super high high med low 3 3 81 ...

Page 82: ...0 1400 1600 1800 2000 80 100 120 140 160 180 200 static pressure Pa air flow m h super high high med low AD482MHERA air flow and static pressure curves 1300 1500 1700 1900 2100 2300 2500 80 100 120 140 160 180 200 static pressure Pa air flow m h super high high med low 3 3 82 ...

Page 83: ...essure varies due to the different steps in high speed The blue dashed line shows the air flow and the static pressure varies due to the different steps in low speed High speed Low speed 55 60 65 70 75 80 8586 0 50 100 150 200 3 4 5 6 7 8 3 4 5 6 7 8 Upper limit air flow m3 min lower limit External static pressure Pa AD722MHERA AD962MHERA 83 ...

Page 84: ...le for total capability of indoor unit group cooling Total capacity of indoor unit group 120 100 80 60 40 20 0 20 40 60 80 100 120 130 Standard capacity Capacity modification coefficient A Capacity compensation coefficient of indoor air wet bulb temperature condition Indoor air wet bulb temperature 1 2 1 1 1 0 0 9 0 8 15 20 24 Capacity modification coefficient B Capacity compensation coefficient o...

Page 85: ...tion factor liquid pipe φ12 7 gas pipe φ22 22 AV08NMVERA 180 160 140 120 100 80 60 40 20 0 0 80 0 85 0 90 1 00 0 95 0 95 1 00 0 90 0 85 0 80 0 20 40 60 80 100 120 140 160 180 180 160 140 120 100 80 60 40 20 0 0 80 0 85 0 90 1 00 0 95 180 160 140 120 100 80 60 40 20 0 0 80 0 85 0 90 1 00 0 95 180 160 140 120 100 80 60 40 20 0 0 80 0 85 0 90 1 00 0 95 0 95 1 00 0 90 0 85 0 80 0 20 40 60 80 100 120 1...

Page 86: ...d pipe φ19 05 gas pipe φ38 1 liquid pipe φ19 05 gas pipe φ31 8 pipe length of single way m cooling compensation factor AV34NMVERA 180 160 140 120 100 80 60 40 20 0 0 80 0 85 0 90 1 00 0 95 0 95 1 00 0 90 0 85 0 80 0 20 40 60 80 100 120 140 160 180 180 160 140 120 100 80 60 40 20 0 0 80 0 85 0 90 1 00 0 95 180 160 140 120 100 80 60 40 20 0 0 80 0 85 0 90 1 00 0 95 180 160 140 120 100 80 60 40 20 0 ...

Page 87: ...xchanger 1 0 0 9 0 8 15 10 5 0 5 10 Outdoor air wet bulb temperature Total capacity of indoor unit group 1 2 1 0 0 8 0 2 0 20 40 60 80 100 120 140 Indoor air dry bulb temperature Outdoor air wet bulb temperature Capacity modification coefficient Standard capacity airflow variation rate Capacity modification value Capacity modification coefficient 0 4 0 6 F Heating compensation factor at different ...

Page 88: ...4 Operation limit Cooling Indoor air WB Heating 45 40 35 30 25 20 15 10 5 0 5 10 10 15 20 25 30 15 10 5 0 5 10 15 20 5 10 15 20 25 30 Indoor air DB Consecutive operation Consecutive operation Outdoor air DB Outdoor air WB ...

Page 89: ...G R U P A d o o 89 11 Refrigerant piping design Outdoor Branch pipe Outdoor Branch pipe Controller Indoor 1 Piping branch system ...

Page 90: ...can be added or reduced at your will on the condtion that the indoor capacity is in the allowable range 2 When the indoor total capacity is more than outdoor nominal capacity the capacity of running indoor will be relatively reduced The capacity of running indoor will not exceed outdoor capacity ...

Page 91: ...e 6 35 9 52 12 7 15 88 19 1 31 8 0 16 0 18 0 20 0 25 0 35 0 55 0 5 0 5 0 5 0 5 0 5 0 5 3 Branch pipe selection Total capacity of indoor units 100W Less than 335 Not less than 335 and less than 506 Not less than 506 and less than 730 Not less than 730 Branch pipe model FQG B335A FQG B506A FQG B730A FQG B1350A ...

Page 92: ...ethod Diameter Connecting method Flared joint 12 7 15 88 15 88 A Outdoor unit Gas pipe side Liquid pipe side Oil pipe side AV08NMVERA AV10NMVERA Diameter Connecting method Brazing Flared joint 9 52 Model 9 52 AV12NMVERA AV14NMVERA AV16NMVERA 9 52 12 7 Diameter Connecting method Diameter Connecting method Brazing Flared joint Flared joint Flared joint 6 35 19 05 22 22 25 4 25 4 28 58 5 Refrigerant ...

Page 93: ...uid pipe L3 total length of 15 88 liquid pipe L4 total length of 12 7 liquid pipe L5 total length of 9 52 liquid pipe L6 total length of 6 35 liquid pipe 6 Requestment of copper pipe specs and thickness Exterior diameter mm 6 35 9 52 12 7 15 88 19 05 22 22 25 4 28 58 31 8 34 9 38 1 41 8 Remarks Pipe thickness mm more than 0 8 more than 0 8 more than 1 0 more than 1 0 more than 1 0 straight pipe mo...

Page 94: ...ence between outdoors in the same system Within 5m better be horizontal Max pipe length from 1st branch pipe to indoor Max 40m Height difference between indoors Max 15m b Pipe length between outdoors 3 outdoor1 outdoor2 outdoor3 L1 10m L2 L3 10m Gas liquid pipe 1st gather pipe 2st gather pipe Oil equalization pipe height difference between outdoors h 5m L5 L6 10m Note a HZG 30 A includes HZG 20 A ...

Page 95: ...G R U P A d o o outdoor1 outdoor2 outdoor3 outdoor1 outdoor2 outdoor3 Installation at high difference outdoor1 outdoor2 outdoor3 95 ...

Page 96: ...o o outdoor1 outdoor2 outdoor3 Oil trap upright projecting pipe 200mm high as the figure outdoor1 outdoor2 outdoor3 Below is forbidden compressor oil will flow into the lowest outdoor outdoor1 outdoor2 outdoor3 96 ...

Page 97: ...40 L7 L13 L14 Main pipe actual length 90 L5 Height difference between indoors 15 Height difference between outdoors 5 outdoor3 outdoor2 over 200mm over 200mm below 2m below 2m L7 L14 L13 40m L1 L5 L14 L15 L13 L12 L11 L10 L9 L8 L7 L6 L2 L3 10m L4 L3 L2 L1 10m outdoor1 max drop 5m outdoor is lower max drop is 40m max drop 15m outdoor is uppper max drop is 50m when the distance between outdoors is ov...

Page 98: ... pipe Gas pipe Liquid pipe 22 6KW φ19 05 φ9 52 φ22 2 φ12 7 28 0KW φ22 2 φ9 52 φ25 4 φ12 7 33 5KW φ25 4 φ12 7 φ28 58 φ12 7 40 0KW φ25 4 φ12 7 φ28 58 φ12 7 45 0KW φ28 58 φ12 7 φ31 8 φ12 7 50 6KW φ28 58 φ15 88 φ31 8 φ15 88 56 0KW φ28 58 φ15 88 φ31 8 φ15 88 98 b Pipe b diameter between branch pipes When the later indoor capacity is less than 14 0KW the specification of pipe b should refer to the data ...

Page 99: ...t indoor is over 90m the main pipe diameter should be enlarged d Pipe d diameter between gather pipes Total outdoor capacity before the gather pipe Liquid pipe a c Gas pipe b d 68 0KW φ15 88 φ28 58 69 0 96 0KW φ19 05 Φ31 8 97 0KW φ19 05 Φ38 1 e Pipe e diameter between outdoor and the gather pipe outdoor capacity Gas pipe Liquid pipe Oil equalization pipe 8HP φ19 05 10HP φ22 2 φ9 52 12 14 HP φ25 4 ...

Page 100: ... c Gas pipe b d 68 0KW φ15 88 φ28 58 69 0KW 96 0KW φ19 05 φ31 8 Over 97 0KW φ19 05 φ38 1 Note When the single pipe length is over 90m the above pipe should be enlarged as the former information 2 Oil equalization pipe connection oil equalization pipeφ9 52 T shape 3 way pipe oil equalization pipeφ9 52 18 32HP 34 48HP 18 32HP 34 48HP Liquid pipe Gas pipe Liquid pipe Gas pipe 8 100 ...

Page 101: ...one power source F The communication wire and the power cable must be individual and can not use one multi core cable or the communication wire will be interfered to cause abnormal Note When one wired controller controls multiple indoors the connected indoor units must use the common phase of power source or the communication will be abnormal For example the power source is L1 L2 L3 and N all the ...

Page 102: ...r and master indoor are connected by 3 polar wires When indoor is controlled by remote controller refer to the wired control master unit wired control slave unit remote control unit table A B C on signal terminal block need not wires and not connect the wired controller outdoor 1 outdoor 2 outdoor 3 P Q A B C A B C indoor 1 indoor 2 indoor 3 indoor 4 indoor 5 indoor 6 indoor 7 indoor 8 indoor 9 in...

Page 103: ...l c When power cable exceeds the range thichen it appropriately d Shielded layer of communication wires must be connected together and be earthed at single point e Communication wire total length cannot exceed 1000m 3 Communication wire for wired controller 100 100 and 200 200 and 300 wire length m wire spec 0 3mm2 3 core shielded wire a Shielded layer of communication wire must be earthed at one ...

Page 104: ... outdoor master unit indoor unit indoor unit indoor unit Unit No 1 Wired controller group control 1 16 Unit No 62 Unit No 63 Unit No 64 Unit No 2 Unit No 3 Unit No 4 Unit No 5 Unit No 6 Unit No 7 Unit No 8 Unit No 9 iGU04 iGU04 Can set the central control unit as a group and the max 64 units of indoor can be set a group After setting unit the indoor in one group can be controlled the same operatio...

Page 105: ...1 50 AB122MCERA 1 50 AB162MCERA 1 50 AB182MEERA 1 50 AB242MEERA 1 50 AB282MEERA 1 50 AB302MEERA 1 50 AB382MEERA 1 50 AB482MEERA 1 50 220 220 220 220 220 220 220 220 220 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 0 5 0 5 0 5 0 69 0 69 0 69 1 38 1 38 1 38 1 6 1 6 1 6 2 2 2 2 2 2 4 4 4 4 4 4 20 20 20 45 45 45 60 60 60 0 4 0 4 0 4 0 55 0 55 0 55 1 1 1 1 1 1 80 80 80 90 100...

Page 106: ...302MMERA 1 50 AD382MMERA 1 50 AD482MMERA 1 50 220 220 220 220 220 220 198 242 198 242 198 242 198 242 198 242 198 242 AD182MHERA 1 50 AD242MHERA 1 50 AD282MHERA 1 50 AD302MHERA 1 50 AD382MHERA 1 50 AD482MHERA 1 50 220 220 220 220 220 220 220 220 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 AD722MHERA AD962MHERA 1 50 1 50 1 79 1 79 1 79 2 42 2 42 2 42 3 8 3 8 3 8 5 8 5 8 5 8 75 7...

Page 107: ...182MCERA 1 50 AC242MCERA 1 50 AC382MFERA 1 50 AC482MFERA 1 50 AC162MCERA 1 50 AS072MCERA 1 50 AS092MCERA 1 50 AS122MCERA 1 50 AS182MCERA 1 50 AS162MCERA 220 220 220 220 220 220 220 220 220 27 27 27 45 45 27 27 27 45 45 1 50 AF072MCERA 1 50 AF092MCERA 1 50 AF122MCERA 220 220 220 220 220 198 242 198 242 198 242 198 242 198 242 0 45 0 45 0 45 1 69 1 69 1 44 1 44 1 44 5 4 5 4 26 26 26 100 100 60 60 10...

Page 108: ...VERA AV40NMVERA AV42NMVERA AV44NMVERA AV46NMVERA AV48NMVERA 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 380 380 380 380 380 380 380 380 380 380 380 380 380 380 380 380 380 380 380 380 380 342 418 342 418 342 418 342 418 342 418 342 418 342 418 342 418 342 418 342 418 342 418 342 418 342 418 342 418 342 418 342 418 342 418 342 418 342 418...

Page 109: ...ication cable Shielded wire Power cable Wiring of indoor units for example Wiring of outdoor units for example 6 Wiring of indoor and outdoor F E D T S S T D E F O8O9O Q Wo other outdoor unit S T Wo power cable O8 O9 O Wo indoor communication O8 O9 O Rutdoor unit 8 Rutdoor unit 9 Wo other outdoor unit Fommunication cable Vhielded wire0 Sower cable ...

Page 110: ...rded as one management port in theory But in fact the system can not be more than 200 management ports and each management system can connect 4 sets network server maximum by HUB 1 3 Network side software Each software can control 20000 sets parameter ports 1 4 PC HBU internet wire electric box pulse ammeter are common devices which will not be supplied by Haier and be purchased by the distributor...

Page 111: ...nit drilling a hole on the site Adopt the flat head tapping screw to fix the gateway to prevent the wires punctured by the wires in the electric box No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 item AC AC NC NC 5V GND M1 GND SUB1 GND SUB2 GND SUB3 GND HB1 HB2 LONA LONB LONA LONB Remarks 13 8V non polar When ammeter connects external power supply there should be a resistor 10K between 5 an...

Page 112: ...t Outdoor master unit Outdoor master unit Outdoor master unit Outdoor slave unit Outdoor slave unit Outdoor slave unit Outdoor slave unit Outdoor slave unit Outdoor slave unit Outdoor slave unit Outdoor master unit Outdoor master unit Outdoor master unit Outdoor master unit 2 2 System diagram MRV II Commercial Air Conditioning PC on client side install network side software internet or intranet or...

Page 113: ...and white wire is connected to the earth wire on the right of HBS 4 Count earth wire pulse signal wiring connect pulse ammeter to get the power consumption recorded in the ammeter Polarity is required HBM HBM HOMEBUS communication port connect ports P Q of the communication terminal block of outdoor master unit and indoor unit no polarity requirement Connect the earth wire terminal of pulse output...

Page 114: ...tion 2 4 Connection among gateways between gateway and server The gateways are interconnected with two core STP the section is 1 5mm2 to make LONWORKS control network The spec of signal wire is as above The wiring of signal wires adopts bus type identical with the communication wires connection between indoor and outdoor If it is very far from gateway to server the wires must be shielded and be he...

Page 115: ... no used A External dimension and installation space requirement Because the internet server is a precise electronic device it should be installed in the control room to connect computers conveniently MRV II Commercial Air Conditioning s w i t c h 115 ...

Page 116: ...ected system then transfer it to the computer 2 Software parameter display and human computer operation surface and account and save the power cost output the cost table 3 RS 485 232 Converter hardware Item 2 3 name is HCM1 1 3 Control range 1 If the H CACSII is necessary pay attention that the indoor quantity of every system cannot be over 40 sets Or the adapter can not work normally 2 Every syst...

Page 117: ...st 1 Protocol adapter needs 220V AC power supply 2 The communication line between indoor and outdoor and the bus line 485 among the protocol adapters should be through steel wire sleeve in the H CACSII 3 Set the indoor central address and the indoor outdoor unit address by hand The system with H CACSII should not set the group function of wired controller ...

Page 118: ...8 Dip switch setting ON 0 OFF 1 left 4 right 4 Shows address of IGU02 address range 1 32 Communication lamp definition RUN SAVE ACCOUNT SLAVE1 SLAVE2 SLAVE3 POWER homebus receiver homebus send RS485 RS485 Wiring terminal ...

Page 119: ...G R U P A d o o 119 Part 5 install the software 1 Install database Firstly install Mysql Database Next ...

Page 120: ...G R U P A d o o 120 Next Next Next ...

Page 121: ...G R U P A d o o 121 Then click Finish installation succeeds Note No need to change the default setting just click next all the way 2 ODBC installation and setting ODBC installation Continue ...

Page 122: ...G R U P A d o o 122 Select mysql then click ok Then click close ODBC setting Open ODBC database in the route control panel manage tool ...

Page 123: ...G R U P A d o o 123 Select system DNS Click and add ...

Page 124: ...G R U P A d o o 124 Select mysql then click finish Input according to the below information in the page Password is 1 Click OK ...

Page 125: ...G R U P A d o o 125 3 Software installation Next ...

Page 126: ...G R U P A d o o 126 Next Click finish Software startup 1 Startup of database In the folder C mysql bin look for winmysqladmin exe and click twice to open it ...

Page 127: ...Note Install mysql for the first time open it then you need enter username and password username is sa password is a Problems in installation If problem occurs the system needs to be re installed Firstly stop mysqld nt exe ...

Page 128: ...l it If it cannot be found modify the search item as the following Choose the three items search system folder search hidden file and folder search sub folder as the figure Stop mysql in service in the manage tool folder if it is already stopped you need not change it ...

Page 129: ...G R U P A d o o 129 ...

Reviews: