background image

Please read this operation manual before using the air 
conditioner. Keep this operation manual for future reference
This appliance is filled with R32.

HAS09FAAIN

HAS12FAAIN

HAS18FAAIN

HAS09TAAIN

HAS12TAAIN

HAS18TAAIN

HAS24TAAIN

OPERATION MANUAL

SPLIT TYPE ROOM AIR CONDITIONER

Summary of Contents for HAS12FAAIN

Page 1: ...ore using the air conditioner Keep this operation manual for future reference This appliance is filled with R32 HAS09FAAIN HAS12FAAIN HAS18FAAIN HAS09TAAIN HAS12TAAIN HAS18TAAIN HAS24TAAIN OPERATION M...

Page 2: ......

Page 3: ...ontacts should not be no less than 3mm Such means for disconnection must be incorporated in the Make sure installation is done according to local wiring regulation by professional persons A leakage ex...

Page 4: ...e must be disconnected from the power supply before replacing or cleaning or other maintenance of the UV C lamp The type of UV C lamp is 0011012908 Front panels bearing the ultraviolet radiation hazar...

Page 5: ...S system must support IOS 9 0 or above Android system must support Android 5 0 or above Configuration method Scan the QR code below to download hOn APP Other Download options Please search hOn APP on...

Page 6: ...ightening and extinguishing of the indoor LED display board 18 POWER ON OFF button 19 DRY button 20 TEMP button 21 SWING UP DOWN button 22 HOUR button 23 EXTRA FUNCTION button 2 Signal sending display...

Page 7: ...emergency operation starts the unit will run automatically in the following modes Room temperature Designated temperature Timer mode Fan speed Operation mode Above 23 o C Below 23 o C 23 o C 26 o C No...

Page 8: ...lting process The hydrophilic aluminium coating with smaller angel 5 helps increase water drainage efficiency Stage 2 56 high temperature sterilisation It utilizes smart temperature monitoring and fre...

Page 9: ...after SLEEP mode starts temp will become 2 lower than temp setting After another 1 hours temp decrease by 2 rises by 1 futher The unit will run for further 3 hours then stops Temp is lower than temp...

Page 10: ...y airflow downwarder Present position All the products are in conformity with the following European provision RoHS The products are fulfilled with the requirements in the directive 2011 65 EU of the...

Page 11: ...t disturbed Place possible to drain easily where piping can be conne cted with the outdoor unit Place where cold air can be spread in a room entirely Place nearby a power receptacle with enough space...

Page 12: ...ft rear piping In case of left side piping cut away with a nipper the lid for left piping In case of left rear piping bend the pipes according to the piping direction to the mark of hole for left rear...

Page 13: ...wiring e r ror Faulty PCB Faulty EEPROM data Faulty EEPROM Faulty PCB Faulty connector connection Faulty therm istor Faulty PCB Room temperature sensor failure The power source must be exclusively us...

Page 14: ...oor unit using vacuum cleaner or flaping them lightly otherwise its performance will be affected the cool and dry conditions For Smart Use of The Air Conditioner Replacement of Air Purifying Filter Th...

Page 15: ...ION PROHIBITION PROHIBITION PROHIBITION Do not start or stop the operation by disconnecting Do not channel the air flow directly at people especially at infants or the aged Do not try to repair or rec...

Page 16: ...he type of T 25A 250V The refrigerating circuit is leak proof Specifications The machine is adaptive in following situation The power plug and connecting cable acquired the local 2 If the power supply...

Page 17: ...abbiano ricevuto supervisione o istruzioni riguardanti l uso dell apparecchio in modo sicuro e capiscano i rischi coinvolti I bambini non devono giocare con l apparecchio Le operazioni di pulizia e m...

Page 18: ...della lampada UVC Il tipo di lampada UVC 0011012908 pannelli frontali con il simbolo di pericolo di radiazioni ultraviolette sono dotati di un interruttore di ngresso per interrompere l alimentazione...

Page 19: ...orto Android 5 0 o superiore Metodo di configurazione Scansiona il codice QR qui sotto per scaricare l APP hOn Per altre opzioni di download si prega di ricercare l APP hOn su App Store IOS Google Pla...

Page 20: ...i prolunga ti Se dovessero apparire delle icone una volta spento basta premere il tasto di reset Modalit operativa QUITE silen zioso SO SPEN SIONE Riscaldamento elettrico integrato BENES SERE ALIMEN T...

Page 21: ...destra Si consiglia di non tenere il deflettore orizzontale verso il basso per molto tempo in modalit COOL o DRY altrimenti potrebbe crearsi acqua condensata modalit COOL orizzontalmente a sinistra e...

Page 22: ...30 minuti per uccidere batteri e virus all interno del condizionatore d aria 3 stadio raffreddamento rapido dell evaporatore per migliorare le prestazioni di sterilizzazione La superficie rivestita c...

Page 23: ...iata la temperatura si abbasser di 2 C rispetto alla temperatura impostata Dopo un altra ora la temperatura scender ancora di 2 C Dopo altre 3 ore la temperatura salir di 1 C L unit rimarr in funzione...

Page 24: ...pegger In base alla sequenza di impostazione dei tempi TIMER ACCENSIONE o TIMER SPEGNIMENTO possono essere ottenuti Start Stop o Stop Start CONFORMIT AI REGOLAMENTI EUROPEI PER I MODELLI Tutti i prodo...

Page 25: ...stra Posteriore destra Destra Inferiore Se si utilizza il tubo di scarico del lato sinistro assicurarsi che il foro ottenuto attraverso La distanza tra l unit interna e il pavimento deve essere superi...

Page 26: ...tubo flessibile di scarico devono esse re fissati insieme al tubo per il refrigerante usando del nastro protettivo Tubature con altre direzioni Tagliare con le tenaglie il coperchio per la tubazione...

Page 27: ...e r r o c o t a n i l c n i a i s e h c o d o m n i o c i r a c s i d e l i b i s s e l f o b u t l i e r a l l a t s n I mente verso il basso Non installare lo scarico come mostrato di seguito V ersa...

Page 28: ...condizionatore 2 Staccare il ltro dell aria standard Far scorrere la rotella leggermente in alto per rilasciare il ltro quindi estrarlo 3 l i e r a s s i F ltro di puri cazione dell aria Inserire i l...

Page 29: ...terra AVVERTENZA Non utilizzare per conservare alimenti opere d arte apparecchiature particolari per l allevamento o la coltivazione Cambiare l aria di tanto in tanto in particola re se contemporaneam...

Page 30: ...rigerante a prova di perdite La macchina adattiva nella seguente situazione 1 Intervallo di temperatura ambiente applicabile L utilizzo di questo apparecchio non idoneo per persone con o mentali ridot...

Page 31: ...FICATO DI GARANZIA CLIMATIZZATORI 24 mesi Qualora consumatore ASSISTENZA TECNICA telefonica 02 400 48 270 ASSISTENZA TECNICA online https go he services assistenza condizionatori Haier Timbro installa...

Page 32: ...per operare in condizioni di sicurezza stabilite dalle normative vigenti e o per rendere accessibile il macchinario 9 In caso di sostituzione di un componente eventualmente difettoso Haier a c ltaly...

Page 33: ......

Page 34: ......

Page 35: ......

Page 36: ...0011520665...

Page 37: ...AAOUT H1U09FAAOUT H1U12FAAOUT H1U18FAAOUT H2U14MAAOUT H2U18MAAOUT H2U14TAAOUT H2U18TAAOUT Please read this manual carefully before installation This appliance is filled with R32 Keep this operation ma...

Page 38: ......

Page 39: ...ents 3 Installation Instructions 3 Relocation Procedures 7 Maintenance Instructions 7 Scrapping and Recovery 10 Indoor Outdoor Unit Installation Drawings 12 Safety Precautions 14 Read Before Installat...

Page 40: ...can easily nd it Install the air conditioner in accordance with the instructions in this installation manual Be sure to use only the specified accessories and parts for installation work Install the...

Page 41: ...s installed in coastal areas or other regions with sulfate gas of salty atmosphere corrosion will occur and the unit service life will be shortened EUROPEAN REGULATIONS CONFORMITY FOR THE MODELS IMPOR...

Page 42: ...driver s cab 8 Orange white or red white reflective stripes shall be pasted on the sides and tail of the transporting vehicles to remind the vehicles behind of keeping distance 9 The transporting vehi...

Page 43: ...re source and oil heater shall be avoided below the indoor unit 4 The power supply shall be provided with earthing wire and be reliably earthed 5 While punching the wall with an electric drill whether...

Page 44: ...ting solution The pressure shall be maintained for more than 5 minutes and then whether the system pressure is reduced or not shall be observed In case the pressure is reduced leakage can be identifie...

Page 45: ...tallation is firm or not The unit may fall vibrate or make a noise Whether the inspection on air leakage is completed The refrigerating capacity heating capacity may be insufficient Whether the unit i...

Page 46: ...ontainer internal refrigeration pipelines and refrigeration elements the maintenance at the user s site is allowed including the cleaning and dredging of the refrigeration system requiring no disassem...

Page 47: ...Nitrogen cylinders acetylene cylinders and oxygen cylinders shall be placed separately The distance between the gas cylinders above and the working area involved in open fire shall be at least 6m The...

Page 48: ...the refrigeration system shall be earthed The refrigerant charged shall be of the type and volume specified on the nameplate Excessive charging is not allowed After maintenance of the refrigeration sy...

Page 49: ...During the use of refrigerant charging tools cross contamination of different refrigerants shall be avoided The total length including the refrigerant pipelines shall be shortened as much as possible...

Page 50: ...vacuumized before usage and be kept under normal temperature if possible The recovery equipment shall always be under favorable working state and be equipped with operation instructions to facilitate...

Page 51: ...tion may affect the house x the unit by attaching a vibration proof mat The marks from to in the gure are the parts numbers The distance between the indoor unit and the oor should be more than 2m more...

Page 52: ...ic cable for indoor and outdoor Drain hose Heating insulating material Piping hole cover Fixing of outdoor unit Fix the unit to concrete or block with bolts 10mm and nuts rmly and horizontally When tt...

Page 53: ...WARNING CAUTION N Open the window and well ventilated the room explosion proof fuse 14...

Page 54: ...32 3 fire or explosion will be caused fire or explosion fire or explosion fire or explosion fire or explosion fire explosion 15...

Page 55: ...R32 2 3 R 2 3 R R32 R32 R32 R32 R32 16...

Page 56: ...shock fire or explosion Install a explosion proof breaker for current leakage at the power source to avoid the risk of the electric shock Do not use large capacity fuses steel wire or copper wire Dam...

Page 57: ...R32 R32 R32 R32 R32 R32 R32 R32 R32 18...

Page 58: ...3 R32 R32 R32 R32 R32 R32 R32 19...

Page 59: ...R32 R32 R32 R32 R32 R32 R32 R32 10A HFC 410A 20...

Page 60: ...istribution Hole Cushion rubber Model W D H L1 L2 L3 H1U09TAAOUT 700 245 543 8 440 120 140 269 H1U12TAAOUT H1U18TAAOUT 800 275 553 510 130 160 313 H1U09FAAOUT H1U12FAAOUT H1U18FAAOUT 820 338 614 590 1...

Page 61: ...Fastening torque Liquid side6 35mm 1 4 18 20N m Liquid Gas side9 52mm 3 8 30 35N m Gas side 12 7mm 1 2 35 45N m Spanner Torque wrench Gas side 15 88mm 5 8 45 55N m Be careful that matters such as wast...

Page 62: ...efrigerant should be charged according to E g m But the charge of refrigerant must be conducted by professional air conditioner engineer Before adding additional refrigerant perform air purging from t...

Page 63: ...24...

Page 64: ...R32 R32 25...

Page 65: ...AOUT H2U14MAAOUT H2U18MAAOUT H2U14TAAOUT H2U18TAAOUT 1 25 20 25 30 ceramic type of T 25A 250V The explosion proof breaker of the air conditioner should be all pole switch The distance between its two...

Page 66: ...2 9 15 8 12 10 5 13 19 1 18 4 11 25 25 25 110 Suction temperature sensor failure When the The wiring of compressor is wrong or the connection is poor 17 16 Lack of refrigerant Check if there is leakag...

Page 67: ...4 253 226 269 226 269 Energy consumption is based on standard test results Actual energy consumption will depend on how the appliance is used and where it is located Pdesignc kW 2 6 3 6 5 0 7 0 2 6 3...

Page 68: ...iposizionamento del condizionatore 7 Istruzioni per la manutenzione 7 Smaltimento e recupero dei materiali 10 Unit esterna interna Schemi per l installazione 12 Norme di sicurezza 14 Leggere prima del...

Page 69: ...gare il circuito refrigerante per escludere che ci sia aria all interno e usare solo il refrigerante specificato R32 Assicuratevi che il collegamento di messa a terra sia eseguito correttamente e sia...

Page 70: ...dell olio e di altre parti sono compiti che competono a un installatore qualificato conformemente alle leggi locali e nazionali pertinenti I condizionatori destinati a riutilizzo riciclaggio e ricond...

Page 71: ...e ai veicoli che seguono di tenersi a distanza 9 Mantenere una velocit uniforme durante il trasporto evitando di accelerare o frenare bruscamente 10 Non trasportare contemporaneamente oggetti infiamma...

Page 72: ...dispositivi ad alta temperatura come focolari e caloriferi a olio 4 Per l alimentazione elettrica prevedere la messa a terra con un sistema affidabile 5 Prima di forare la parete con un trapano elett...

Page 73: ...o una soluzione specifica per rilevare le perdite Mantenere la pressione per pi di 5 minuti e verificare se nel frattempo la pressione del sistema scesa Se la pressione scesa significa che c una perdi...

Page 74: ...ontrollo delle perdite d aria stato completato La capacit di raffreddamento di riscaldamento potrebbe essere insufficiente L unit completamente isolata Possibile formazione di condensa o di gocce d ac...

Page 75: ...elementi per il raffreddamento compresa la pulizia del sistema frigorifero purch non serva smontare i pezzi e non siano necessarie saldature Se durante l intervento di manutenzione necessario cambiare...

Page 76: ...on consentito L interruttore di alimentazione generale deve esser montato fuori dall officina e dovr essere munito di apposito dispositivo di protezione antideflagrante Le bombole di azoto acetilene e...

Page 77: ...ua di refrigerante al loro interno Le bombole del refrigerante devono essere mantenute in posizione verticale e fissate Assicurar si che il sistema frigorifero sia messo a terra prima di caricare il r...

Page 78: ...pistola per saldatura I tubi di raffreddamento possono essere smontati esclusivamente con una taglia tubi e in prossimit di una presa di aerazione Procedure per caricare il refrigerante In aggiunta al...

Page 79: ...ero vanno usate per un solo tipo di refrigerante bombola dedicata per il refrigerant e di recupero Le bombole devono essere dotate di valvole di pressione e di intercettazione funzionanti Se possibile...

Page 80: ...talla l unit su pareti tetti o tettoie prevedere un supporto ben fissato con chiodi o cavi tenendo conto di eventi quali terremoti e venti forti Se la casa soggetta a vibrazioni fissare l unit unit us...

Page 81: ...erna Fissare l unit alla pavimentazione o al blocco di cemento stringen do bene dadi e bulloni 10mm e accertarsi che l unit sia a livello orizzontale Quando si installa l unit su pareti tetti o tettoi...

Page 82: ...a dell unit interna Lasciare la ventola scoperta molto pericoloso poich potrebbe ferire chi usa il condizionatore Se servono interventi di manutenzione e riparazione contattare il fornitore affinch se...

Page 83: ...entrare nell unit polvere o l acqua con associato rischio di folgorazione fumo e incendio Durante l installazione o lo spostamento del condizionatore utilizzare soltanto il refrigerante R32 come indic...

Page 84: ...oteggere parti svasate cartellate e raccordi flangiati La presenza di troppo olio minerale potrebbe causare il degrado dell olio della macchina frigorifera Utilizzare liquido refrigerante per caricare...

Page 85: ...le istruzioni nel manuale e assicurarsi che l acqua sia drenata correttamente per evitare la formazione di condensa Se le tubature non vengono installate correttamente potrebbero causare perdite d ac...

Page 86: ...lore rosa Porta di caricamento bombola refrigerante Caricamento del refrigerante Diametro del tubo flessibile maggiore di quello dei tubi convenzionali Dado svasato flare Collegamento dell unit alle t...

Page 87: ...ni maggiori di quelle previste per le unit che utilizzano l R22 Dimensione della svasatura mm Se si utilizza una cartellatrice a frizione sulle unit che impiegano l R 32 la parte del tubo che fuoriesc...

Page 88: ...vacuometro che possa misurare fino a 650 Pa Non utilizzare un manometro qualunque poich non pu misurare un vuoto di 650 Pa 4 Tempo di svuotamento Svuotare l apparecchiatura per 1 ora dopo aver raggiu...

Page 89: ...il vento forte entri direttamente nella bocchetta di uscita del flusso d aria 3 Tenere uno spazio libero di almeno un metro sopra l unit 4 Non bloccare l area intorno all unit 5 Se l unit esterna vie...

Page 90: ...quantit E g m riportata Il caricamento del refrigerante deve essere eseguito da un tecnico specializzato Prima di aggiungere altro refrigerante sfiatare l aria dalle tubature del refrigerante e dall...

Page 91: ...i refrigerante in base a 20 g m Prima di aggiungere altro dell aria dalle tubature del refrigerante e dall unit interna usando una pompa a vuoto poi caricare il refrigerante B A1 B1 A2 B2 B1 B2 A3 A1...

Page 92: ...ercare il punto di perdita Mettendo in pressione per 24 ore una variazione di 1 C della temperatura dell ambiente causer una variazione di pressione pari a 0 01 MPa 0 1kg cm2 g Tenerne conto durante i...

Page 93: ...trollo per verificare che non ci siano perdite di gas 5 Non ci sono perdite di gas Se ci sono perdite di gas stringere i giunti del tubo Se la perdita si arresta procedere al punto 6 Se la perdita non...

Page 94: ...mm Tali dispositivi di disconnessione scollegamento devono essere integrati nel cablaggio fisso La distanza tra le due morsettiere dell unit interna ed esterna non deve superare i 5 m Se superiore il...

Page 95: ...lta pressione Alta pressione del sistema superiore ai 4 3 MPa 8 Dispositivo di protezione temperatura di scarico del compressore Temperatura di scarico del compressore superiore ai 110 C 9 Anomalia de...

Page 96: ...etico effettivo dipender dal modo in cui viene utilizzato l apparecchio e dalla posizione in cui si trova Pdesignc kW 2 6 3 6 5 0 7 0 2 6 3 5 5 2 4 0 5 0 4 0 5 0 Prestazioni nella modalit riscaldament...

Page 97: ......

Page 98: ......

Page 99: ......

Page 100: ...0011520666...

Reviews: