background image

Art.- Nr. 161 82 60

1-channEl rEcEiVEr 

HT1E

www.h-tronic.de

This receiver has been designed as a tap-proof and tamper 
free remote control. The connection between the transmit-
ter (e.g. HT5S or HT8S) and the receiver is encrypted by 
AES128 and contains a “rolling code”. This makes each 
data package sent to the receiver unique and non-repeat-
able. The learnable receiver allows the operation of up 
to 32 different transmitters that can be programmed into 
the receiver by pressing a key. The relay outputs have a 
changeover contact that may be freely connected. Due to 
the characteristics of the device, this remote control system 
is ideal for general installation purposes and alarm technol-
ogy. It can be used as a wireless connection for almost all 
electronic systems at home, in the garden, in the office or in 
the workshop. This one channel receiver can, for example, 
open your garage door, your window blinds, switch sock-
ets and internal lighting as well as alarm system. Wireless 
technology has a variety of applications as no cables are 
needed. This especially applies to outdoor lighting, con-
trolling the pump in the pond or switching on the watering 
system of the garden. 

spEcificaTions

Operating voltage: 12 V DC
Power consumption: 80 mA max.
Operating frequency: 868.35 MHz
Mode: Tip or switch function
Follow up time relay: 200 ms
Outputs: 1 x relay (potential free)
Max. load: 230VAC/5A or 24VDC/5A

Dear customer,

to ensure a correct operation of this device, please read 
these instructions completely and carefully before use. 
Please take into consideration that this manual contains im-
portant information on the operation and use of this device.
This instruction manual is part of the device. Please keep 
this manual in a safe place for future reference. If you pass 
the device on to a third person, please make sure that you 
also pass on the manual. Damages caused by failure of fol-
lowing the instructions in the manual will void the warranty.
No liabilities will be taken for consequential damages. This 
product is certified according to the applicable EC direc-
tives for Electromagnetic Compatibility and complies with 
statutory requirements.

DEsignaTED usE

The designated use of this device is the remote switching of 
electrical loads without safety related applications in con-
junction with a 5-channel transmitter, order number 161 81 
60 or a 8-channel transmitter, order number 161 81 80. 
Any other use than the specified is not permitted.

noTEs on opEraTion

The frequency range of 868 MHz is a frequency used for 
industrial, scientific, medical, domestic or similar radio de-
vices (SRD band). When operating in this frequency range 
interference from other radio equipment may occur. A fully 
reliable function cannot be guaranteed. The user is respon-
sible for installing the device according to the rules and 
regulations of the country in which the transmitter is operat-
ed and maintained. This also relates to the application for 
which the device is being used

for your safETy: 

Be extremely cautious when you 

are switching 230 V devices! There is the danger of an 
electric shock! Inside the housing there are components with 
high-voltage. Touching these whilst the device is connected 
can be hazardous. All installation and maintenance on the 
power supply and the device must be performed by a quali-
fied electrician only. If the relay switches devices higher than 
35 V, the receiver should be installed in a separate housing 
with touch protection.

Qualifications for a reliable installation are also required 
in the field of wireless transmission, of control commands, 
relevant health and safety regulations, accident prevention 
regulations, directives and generally accepted engineering 
standards. (E.g. DIN standards and VDE regulations), tech-
nical rules and regulations to such an extent, that installation 
can guarantee a safe working condition of the equipment 
for the wireless transmission control commands.

DisconnEcT powEr

Make sure that the device cannot be switched on again 
during maintenance or installation.
Check the device for the absence electrical current before 
starting maintenance or installation.
Before switching on the device, make sure that the housing 
is securely closed and that no life wires can be touched.

warning / insTallaTion

safETy insTrucTions:

The installation of the device may only be performed by a 
qualified electrician.
During installation, the main supply (230 V) needs to be 
disconnected. The rules and regulations of the country in 
which the device is being installed need to be followed.
This device is not intended for the control of electrical equip-
ment performing safety-related functions. In normal opera-
tion there is a risk of malfunction due to a general failure or 
a malfunction of the output stage or signal transmission. The 
user needs to ensure that there are no consequential dam-
ages possible due to malfunction or an undefined switching 
state.
–  Due to incorrect tightening of the screws on the termi-

nals or by use of inappropriate tools, the terminals may 
be damaged causing the insulation to fail or the contact 
to become loose. Badly connected cables can become 
loose during operation and become a hazard, has the 
increased contact resistance at the terminal connection 
will cause heat which could result in a fire. Incorrectly 
wired connections can destroy electrical components and 
cause other damage.

–  This product is not approved for the use in connection 

with safety critical applications! If this device is used in 
conjunction with safety critical applications, additional 
security requirements are to be installed, if need be in 
conjunction with other licensed products.

–  This device may not be used by children over the age of 

eight and people with reduced physical, sensory or men-
tal capabilities, or lack of experience and knowledge, 
unless under supervision or given instruction concerning 
the safe use of the equipment and the understanding of 
possible risks. Children should not play with the device. 
Cleaning and user maintenance should not be performed 
by children without supervision.

warnings anD safETy

Please follow the additional safety instructions in order to 
avoid malfunction, damage and health problems.
–  The operation of the device in adverse environmental 

conditions must be avoided under all circumstances. 
Functional temperatures range from -10°C – +40°C. 
Keep the device away from flammable gases, solvents, 
vapors, dust or humidity above 80% as well as spray 
water.

–  The receiver may be operated in a dry room only.
–  Connecting devices with an operating voltage ≥ 35 V 

DC or≥ 25 V A/C must be performed by a qualified 
electrician who is familiar with the relevant safety reg-
ulations.

This device may not be used in connection with safety rel-
evant systems or machines.
–  Before opening the receiver, make sure that it is discon-

nected from all power sources.

–  If it can be assumed that safe operation is no longer pos-

sible, that device must immediately be deactivated and 
secured against inadvertent operation. Safe operation is 
given if the device is not functioning, is visibly damaged, 
has become wet or stored under damp conditions.

–  If you are at any time in doubt about the application or 

the wiring or the installation, immediately seek the advice 
of a professional or the manufacturer.

–  Service and repair should only be performed by author-

ized persons.

–  When installing the device, adequate cables with suffi-

cient cross section are to be used.

–  The protection of the relay circuits is not preassembled 

within the device. The protection of the relays must be 
assembled externally in the connecting cables. (12 A)

–  The relay contacts do not separate the electrical circuit in 

their open state completely. Therefore the only functional 
switching of the operator devices is possible. The relay 
contacts are electrically isolated from the control elec-
tronics. If it is not clear which characteristics apply for 
a component or a module, how to components install 
an external circuit or what external components or ad-
ditional devices may be connected, or which values of 
the external components are allowed, please consult an 
expert and specialist. Make sure that all connected de-
vices and modules are suitable for the device and appli-
cation. Please note that operating and connection errors 
are beyond our control. No liability will be taken from 
damages resulting from connection and operating errors.

–  The accident prevention regulations of the professional 

associations for electrical systems and equipment should 
be strictly followed when installing this device in commer-
cial buildings.

–  In schools, training centers, clubs and workshops, the 

operation of modules and devices must be monitored by 
trained personnel.

–  If the device should be serviced repaired, only original 

spare parts may be used. The use of incorrect spare parts 
can cause serious damage and personal injury! 

Dispose of the packaging material carefully and keep it 
out of reach of children. There is a danger of suffocation.

sEcuriTy noTEs accorDing To r&TTE: 

These wireless remote controls are only permitted for 
equipment and installations where radio interference to the 
transmitter or receiver does not result in danger to persons, 
animals or property other than if the risk of malfunction 
is covered by other safety devices. The control of mobile 
radio controlled devices with a risk of accident may only 
be performed with the direct visual contact of the controlled 
device and if the area is clear of people, animals and ob-
jects. To secure the device from unintended use, make sure 
that the remote control is kept in a safe place inaccessible 
to children or animals.

warning

The use of this remote control is only permitted in combi-
nation with equipment in which radio interference to the 
transmitter or receiver does not result in danger to persons 
or property. Furthermore manual overriding emergency 
stop should be integrated in the setup. The remote control 
of devices and systems with an increased risk of accidents 
is not allowed. Crane and lifting equipment of any kind 
may not be used in connection with this remote control. The 
directives ZH 1/547 are not met.
This remote control may only be operated if the operated 
device is clearly visible. For damages of any kind caused 
by external influences, for faulty connections or negligent 
operation, no liability will be taken.

3. lED Display

The function display consists of 3 LEDs which have the fol-
lowing meaning:

1.

  LED “

Power

”: the device is connected and under power.

2.

  LED”

Learn

”: the device is in learning mode.

3.

  LED”

Error

”: the LED is displayed in the following cases: 

  – the station list is full
  –  an error has occurred whilst reading/writing the  

EEPROM memory

4. lEarning procEss

The receiver is capable of learning up to 32 keys (e.g. 
of receivers HT-8S or HT-5S). First remove the cover of the 
housing. Here you will find three LEDs and a button. The 
learning process consists of the following steps:

1.   

Press the button BTN1 

“Learn”

 briefly. The LED 

“Learn” 

will light up. This means the programming mode is ac-
tive.

2.   

Press the desired station key on the transmitter within 10 
seconds. The LED 

“Learn”

 will start blinking.

3.

   Press the button BTN1

 “Learn

” again. The LED

 “Learn” 

will go out. The learning progress is now ended.

4.

   If you want the relay to only switch when two buttons 

are pressed at the same time (safety circuit) and both 
buttons need to be pressed during the learning se-
quence.

5. sETTing ThE opEraTion moDE

Setting the operation mode consists of the following steps:

1.

   Press the button BTN1 

“Learn

” briefly. The LED 

“Learn” 

will light up. This means the programming mode is ac-
tive.

2.

   Press the

 “taught”

 key on the transmitter (*) within 10 

seconds.

3.   

The LED 

“Learn” 

will blink. The operation mode will now 

be switched from 

“T”

 = touch function to 

“R”

 = latch 

function or from 

“R”

 to 

“T”

. The settings are saved to the 

memory and the device is automatically restarted.

*The transmitter must previously have gone through the 
programming sequence and the receiver must have learnt 
its code.

6. DElETing ThE sTaTion mEmory lisT

A maximum of 32 transmitters can be programmed. If 32 
stations have already been programmed into the receiver, 
no additional transmitters can be programmed. Previously 
learnt codes are not lost. After deleting all transmitters, new 
transmitters can be programmed again.

If the transmitter list needs to be cleared and reset, the dele-
tion can be made with the following steps:

1.  

Separate the receiver from the power supply.

2.  

Press and hold the button 1 “Learn”.

3.  

Reconnect the device to the power supply.

4.

  The LED “Learn” will light up.

5.  

Wait till the LED starts blinking rapidly.

6.

   Release the button “Learn”. All programmed transmitters 

are now deleted.

The receiver can now be programmed with new transmit-
ters.

This insTallaTion anD connEcTion

Connect the device to a suitable power supply (12 V 
DC/200 mA). Make sure that the correct polarity of the 
+12 V DC is connected to the relay output. The maximum 
load per relay is 230 VAC/5 A or 24 V DC/5 A. 
External consumers should be directly connected to the relay 
terminals according to the printed circuit symbols.

The housing is labeled with the pin assignment of the relay 
(Ö= open contact, S= closed contact, C= common connec-
tion for Ö or S). 
As electrical loads, DC or AC can be connected, make 
sure that you establish a secure connection of the cables to 
the terminals, particularly when connecting mains voltage. 
All consumers should be protected by their individual fuse 
(max. 5A).

Although the relay may be positioned in the open state, it is 
still be connected to the mains. Therefore only a functional 
On/Off switching of the mains powered units is possible. 
The relay contacts are electrically isolated from the control 
electronics.

guaranTEE/warranTy

This device has a guarantee of two years. The warranty in-
cludes the repair of faults that can be detected due to the use 
of faulty materials or bad workmanship. The installer of the 
device must ensure that all legal and regulatory requirements 
for the installation are met.
Ignoring the details of this instruction manual will void the 
warranty.
For consequential or incidental damages in connection with 
this product, no liabilities will be taken. 
We reserve our right to repair, replace or refund the pur-
chase price in the case of warranty.

The following cases will void the warranty:

–  Changing, reworking or repairing the device.
–  Changing the functionality or layout of the device.
–  Using other components than original parts or components 

approved by the manufacturer.

–  Damages caused by not following the instructions and 

wiring diagram.

–  Damages caused by overloading the device.
–  Damages caused by third parties.
–  If the device is connected to an incorrect voltage current.
–  Damages caused by incorrect or negligent operation.
–  Damages caused by incorrect installation. E.g. missing/

bridged fuses. 

–  If warranty is not given, all costs and the returning of the 

device is at the user’s expense.

EnViromEnT

Consumers are legally obligated and responsible 
for the proper disposal of electronic and electrical 
devices by returning them to collecting sites desig-
nated for the recycling of electrical and electronic 

equipment waste. This device and/or components within 
the device can be recycled. For more information concern-
ing disposal sites, please contact your local authority or 
waste management company. 

Lerntaste

Empfangs-Antenne

Fehler

Einlernen

Betriebsspannungs-Anzeige

12V =

+

-

Relaiskontakt

COM

NC

NO

„COM“ =  gemeinsame Anschluss 

„NC“   Normally Closed (Ruhekontakt) Relaiskontakt  ist im Normalzustand geschlossen, 

wenn Relais stromlos  

„NO“ Normally Open (Arbeitskontakt) Relaiskontakt ist im Normalzustand geöffnet, 

wenn Relais stromlos 

Verbraucher

Anschlussbeispiel

+

-

12V

Betriebsspannung

com

“  =  gemeinsamer Anschluss

nc

“   =   

n

ormally 

c

losed  

Relay contact is closed in 
normal condition when  
relay is power-off  

no

“   =   

n

ormally 

o

pen  

Relay contact is opened  
in normal condition when  
relay is power-off 

connEcTion plan

This manual is a publication of H-TRONIC GmbH, Industriegebi-

et Dienhof 11, D-92242 Hirschau, Germany. All rights including 

translation reserved. Information provided in this manual may 

not be copied, transferred or put in storage systems without the 

express written consent of the publisher. Reprinting, also for 

parts only, is prohibited. This manual is according to the techni-

cal data when printed. This manual is according to the technical 

status at the time of printing and is a constituent part of the 

device. Changes in technique, equipment and design reserved. 

© Copyright 2016 by H-TRONIC GmbH

 Diese Bedienungsanleitung ist eine Publikation der H-TRONIC 

GmbH, Industriegebiet Dienhof 11, 92242 Hirschau. Alle Rechte 

einschließlich Übersetzung vorbehalten.  

Reproduktionen jeder Art, z.B. Fotokopie, Mikroverfilmung 

oder die Erfassung in EDV-Anlagen, bedürfen der schriftlichen 

Genehmigung des Herausgebers. Diese Bedienungs anleitung 

entspricht dem technischen Stand bei Drucklegung und ist 

Bestandteil dieses Gerätes. Irrtümer und Änderung in Technik, 

Ausstattung und Design vorbehalten.  

Receiving antenna

Operating  voltage  display   

Relay contact

COM

NC NO

12V

12V=

Consumer

Operating voltage

Connection example 

Error

Learn

Learn 

button 

cE marK anD conformiTy

We, the manufacturer (H-TRONIC GmbH) hereby declare that 
this equipment (1-Channel Receiver), is in compliance with the 
essential requirements and other relevant provisions of Directive 
2014/53/EU. CE conformance has been certified –  
the relevant records are in the hands of the manufacturer:  
H-TRONIC GmbH, Industriegebiet Dienhof 11, 92242 Hirschau

1-Kan-Empf-Anleitung.indd   7-12

25.02.16   15:25

Summary of Contents for HT1E

Page 1: ...or switching on the watering system of the garden spEcificaTions Operating voltage 12 V DC Power consumption 80 mA max Operating frequency 868 35 MHz Mode Tip or switch function Follow up time relay 2...

Page 2: ...make sure that the housing is securely closed and that no life wires can be touched warning insTallaTion safETy insTrucTions The installation of the device may only be performed by a qualified electri...

Page 3: ...evices is possible The relay contacts are electrically isolated from the control elec tronics If it is not clear which characteristics apply for a component or a module how to components install an ex...

Page 4: ...annung com gemeinsamer Anschluss nc normally closed Relay contact is closed in normal condition when relay is power off no normally open Relay contact is opened in normal condition when relay is power...

Page 5: ...is in learning mode 3 LED Error the LED is displayed in the following cases the station list is full an error has occurred whilst reading writing the EEPROM memory 4 lEarning procEss The receiver is...

Page 6: ...r from the power supply 2 Press and hold the button 1 Learn 3 Reconnect the device to the power supply 4 The LED Learn will light up 5 Wait till the LED starts blinking rapidly 6 Release the button Le...

Page 7: ...d electrical devices by returning them to collecting sites desig nated for the recycling of electrical and electronic equipment waste This device and or components within the device can be recycled Fo...

Reviews: