PATROL – 201/PET/
PASSIVE INFRARED
OPTOELECTRONIC
INTRUSION DETECTOR
WITH PET IMMUNITY
UP TO 20 KG
INSTALLATION
AND USER MANUAL
www.gsncompany.com
G.S.N. Electronic Company Ltd.
Special features.
Hi – tech design
Automatic pulse count
Animal’s weight regulator
Optoelectronic switch relay
Hi-light immunity –
no less then 10000 Lux
Hermetically insulated
pyrosensor
Low temperature mode
of working
Automatic temperature
compensation
High RFI & EMI immunity.
Description.
«PATROL-201/PET/» – passive
infrared detector with dual element
pyrosensor, was designed for
use in electronic alarm and
security systems
.
The detector is insensible to
animals with weight up to
20 kg and height up to 1 meter.
The usage of “Fresnel Technologies”
company’s original, optical,
lightproof lens, has allowed to
create the detector, which is
protected from false alarms,
caused by a sunlight.
Selecting mounting location.
Choose a location where
the detector will have a best view
angle of the most possible intrusion
sight. To gain maximum protection
zone, it is recommended to place
a detector on
2.1
meter height
Attention!
Avoid the following locations:
Areas with rapid temperature
changes.
Areas with strong air flows
On unstable or vibrating
surface.
Detector performance improves,
if it's located in thermo stable and
dynamically constant environment.
Mounting the detector.
1. To remove the front cover, push
the lower part of the case with a flat
screwdriver
2. Loosen the screw that holds
the PCB and move it, down to
the keyhole. Remove the PCB from
the plastic case.
3. Detector can be placed vertically
or at a small angle (up to 10°).
- For vertical mount use the holes
on the front side of the back cover.
- Use a bracket for mounting the
detector at an angle.
4. For wires connection use
the specially signed holes on
the plastic case of the detector.
5. Mount the back cover of
the detector to the wall.
6. Place the PCB back in the cover
and fix the correct position
with a screw.
7. Connect the wires according to
the scheme.
+ 12V
-
TAMPER RELAY
8. For vertical mount place
the PCB in the
"A"
position.
9. For mounting on a bracket
place the PCB in the
"B"
position.
10. Close the detector’s cover
and fasten the screw.
Pulse count.
«PATROL-201/PET/» -automatically
chooses and counts the levels of
the entering impulses, according
to the strength of the signals acting
on the detector.
Animal’s weight regulator.
The given regulator adjusts
the detector to the weight of
the animal.
20kg
15kg
10kg
5kg
Led indicator.
OFF
ON
JP 2
LED
OFF
ON
JP 2
LED
Jumper's
"ON"
position – LED is
activated and will light on in case
of intrusion.
Jumper's
"OFF"
position – LED is
turned off.