background image

This manual provides information for:

OPERATOR MANUAL

IMPORTANT INFORMATION, KEEP FOR OPERATOR

PART NUMBER 174840, REV. C (07/17)

MODELS TDB (C,A) & 

TDBC (C,A) 

Domestic

STEAM JACKETED 

KETTLE

· Self Contained

· Electrically Heated

· Table Top Mounted

· Tilting

THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE.  

READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND 

WARNINGS CONTAINED IN THIS MANUAL.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors 

and liquids in the vicinity of this or any other appliance.

WARNING

Improper  installation,  adjustment,  alteration,  service 

or  maintenance  can  cause  property  damage,  injury  or 

death.  Read the installation, operating and maintenance 

instructions thoroughly before installing or servicing this 

equipment.

NOTIFY CARRIER OF DAMAGE AT ONCE

It is the responsibility of the consignee to inspect the container upon receipt of 

same and to determine the possibility of any damage, including concealed dam-

age. Unified Brands suggests that if you are suspicious of damage to make a 

notation on the delivery receipt. It will be the responsibility of the consignee to file 

a claim with the carrier. We recommend that you do so at once.

Manufacture Service/Questions 888-994-7636.

Information contained in this document is known to be current and accurate at the time 

of printing/creation.  Unified Brands recommends referencing our product line websites, 

unifiedbrands.net, for the most updated product information and specifications.

1055 Mendell Davis Drive 

Jackson, MS 39272

888-994-7636,  fax 888-864-7636

unifiedbrands.net

Summary of Contents for TDB 20A

Page 1: ...nstructions thoroughly before installing or servicing this equipment NOTIFY CARRIER OF DAMAGE AT ONCE It is the responsibility of the consignee to inspect the container upon receipt of same and to det...

Page 2: ...WHEN ADDING INGREDIENTS STIRRING OR TRANSFERRING PRODUCT TO ANOTHER CONTAINER WARNING DO NOT STAND ON OR APPLY UNNECESSARY WEIGHT OR PRESSURE ON THE KETTLE FRONT OR POURING LIP THIS COULD RESULT IN O...

Page 3: ...BBER GLOVES GOGGLES OR FACE SHIELD AND PROTECTIVE CLOTHING CAREFULLY READ THE WARNINGS AND FOLLOW THE DIRECTIONS ON THE LABEL OF THE CLEANER TO BE USED CAUTION USE OF ANY REPLACEMENT PARTS OTHER THAN...

Page 4: ...e 24 25 Service Log page 26 KLENZADE SALES CENTER ECOLAB Inc 370 Wabasha St Paul Minnesota 55102 800 352 5326 or 612 293 2233 NATIONAL FIRE PROTECTION ASSOCIATION 60 Battery March Park Quincy Massachu...

Page 5: ...single electrical connection is required for installation The unit may be ordered for use with 208 240 or 480 volt power All 208 240 volt kettles are wired for 208 volt three phase operation For 240...

Page 6: ...ion date and retain this information for future reference Space for these entries is provided at the top of the Service Log at the back of this manual Keep this manual on file and available for operat...

Page 7: ...e unit They can be found in a plastic bag attached to the trunnion assembly inside the control box a For conversion from 208V 3 phase to 208V or 240V 1 phase or 480V 3 phase to 480V 1 phase i Verify t...

Page 8: ...x near the UL dataplate 5 Bring incoming electrical service through the conduit fitting for 240V 1 phase a new one inch conduit fitting is required at the rear of the support housing making a watertig...

Page 9: ...come on immediately and heating should continue until the water boils 5 To shut down the unit turn the main power switch to OFF If the unit functions as described above it is ready for use If the unit...

Page 10: ...and 10 The current setting will be reflected on the display c Heating indicator light located on the control console lights when the controller energizes the heating elements and will cycle on and off...

Page 11: ...presets cannot be used to change the setpoint once a TIMER has started j READY alarm The control will sound 3 beeps when the unit has reached within 20 degrees of set point during pre heat and when a...

Page 12: ...in a tilted position and slowly return the kettle body to an upright position DO NOT release handle when kettle is partly tilted It will impact in either the upright or fully tilted position and may...

Page 13: ...ds Get help from another person if the basket is too heavy for safe handling d Slowly lower product into kettle e When removing baskets with cooked product lift straight up ensuring basket bottoms cle...

Page 14: ...le is cooling below the set point the switch closes the heating indicator light comes on the contactors close and the heaters come on again On off cycling continues keeping the kettle at the set tempe...

Page 15: ...Do NOT use abrasive materials or metal tools that might scratch the surface Scratches make the surface harder to clean and provide places for bacteria to grow Do not use steel wool which will leave pa...

Page 16: ...sanitizing agent from your supplier of sanitizing products Following the supplier instructions apply the sanitizing agent after the unit has been cleaned and drained Rinse off the sanitizer thoroughl...

Page 17: ...seconds Then release the ring and permit the valve to snap shut If the ring does not activate if there is no discharge or if the valve leaks stop using the kettle immediately and contact a authorized...

Page 18: ...ion must be removed because it will make heating less efficient Follow the procedure in Jacket Vacuum Removing Air From Jacket above to restore a negative pressure reading 5 Water Treatment a Fill a m...

Page 19: ...he same AMP rating X d For loose or broken wires X e Tilt cut off switch X f That pressure switch is open X g Operation of temperature control X h Low water cutoff X Kettle will not heat but heating i...

Page 20: ...20 OM TDB TDBC Parts List for TDB For Classic Advanced Control Models...

Page 21: ...OM TDB TDBC 21 Parts List for TDB For Classic Advanced Control Models...

Page 22: ...22 OM TDB TDBC Parts List for TDBC For Classic Advanced Control Models...

Page 23: ...5229 18a ELECTRICAL MOUNT ASSEMBLY 480V 175579 19 ELECTRICAL MOUNT ASSEMBLY HAND TILT 208 240V 175439 19a ELECTRICAL MOUNT ASSEMBLY 480V 175440 20 TILT SWITCH 002982 21 CONTACTOR 148102 22 GROUND TERM...

Page 24: ...24 OM TDB TDBC Wiring Diagram For Classic Control Models...

Page 25: ...OM TDB TDBC 25 Wiring Diagram For Advanced Control Models...

Page 26: ...26 OM TDB TDBC Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By...

Page 27: ......

Page 28: ...REV C 07 17 1055 Mendell Davis Drive Jackson MS 39272 888 994 7636 601 372 3903 Fax 888 864 7636 unifiedbrands net 2017 Unified Brands All Rights Reserved Unified Brands is a wholly owned subsidiary o...