background image

Immersion

heater timer

IHT/T   (GPT/T)

IHT/W  (GPT/W)

A   G E   P o w e r   C o n t r o l s   C o m p a n y

Grässlin UK

Vale Rise

GB-Tonbridge/Kent TN9 1TB

Tel  (0 17 32) 35 98 88

Fax  (0 17 32) 35 44 45

www.tfc-group.co.uk

Installation - General Notes

1. Installation should be carried out in accordance  

  with the current edition of the I.E.E. Wiring  

  Regulations. It is recommended that installation is  

  undertaken only by a qualified electrician.

2.  The timer should not be mounted on an unearthed  

  metal or metallised surface.

3. If the timer is to be connected to an appliance that is  

  required to be earthed the supply earthing conductor  

  and the appliance earthing conductor should be 

  terminated together in the earth terminal provided  

  within the timer.

4. It must be ensured that the brass inter-connecting 

  link is correctly positioned and retained in the  

  terminals during connection of the supply conductors  

  (applicable to types IHT/T and IHT/W).

5.  When cutting out the required apertures in the cover  

  to accommodate the input and output cables/cords it  

  should be ensured that no sharp edges remain. 

6. All terminals are suitable for fixed cables, and for 

  flexible cables or cords.

7. For stranded wires use ferrules supplied.

Installation Procedure

1. Switch the supply off at the mains. Means of dis-

  connection from the supply having at least 3mm 

  contact separation in all poles must be incorporated  

  in the fixed wiring mains supply. 

2. Loosen screws (a) and separate housing from timer  

  base. Pull timeswitch module off backplate. Offer  

  backplate to mounting location and mark fixing  

  points b, c and d. Drill wall for screw fixings. Fix  

  backplate to wall. Push timeswitch module onto 

  backplate, ensuring  good engagement of tab 

  terminals with receptacles.

3. Bare wires for 6mm (1/4 inch) maximum; insert into  

  terminals and secure with the screws, in accordance  

  with circuit diagram label beneath terminals. 

4.  Secure cables/cords with clamp provided and check  

  all wiring (see figure 4). Note: Mains supply using  

  fixed wiring does not need to pass through clamp. 

5.  Cut out cable entries on underside of housing as  

  necessary to accomodate cables/cords. Please refer  

  to 5. above. 

6.  Refit housing to timer base. 

7.  Switch on mains. 

Installation as general purpose timer

If you are not controlling an immersion heater, but 

you are still controlling a mains-fed load, please wire 

in accordance with “Immersion Heater Connections” 

diagram shown in this instruction. If the timer is supplied 

by the mains, but you wish to control a circuit which 

must be kept electrically separate to the incoming mains 

supply, please follow the instructions below. 

Removal of the “bridge wire” between terminals 2 and 

3 enables the timer to be used as a general purpose 

timer, since the switch is then electrically separate from 

the mains input to the motor. The switch can then be 

used to control a separate circuit. When installing as 

a general purpose timer, follow instructions 1. and 2. 

above, then slacken screws to terminals 2 and 3 and 

remove bridge wire; affix general purpose timer wiring 

diagram provided over existing IHT wiring label; wire in 

accordance with general purpose diagram, then follow 

instructions 4. to 7. above. 

Setting up

Rotate minute hand until arrowhead on clock face, 

aligns with correct time on outer dial. i. e. 8=8.00 

a.m., 18=6.00 p.m. (see figure 1). When setting up 

seven day version (IHT/W, GPT/W), align correct time 

on outer dial, within current day sector of dial. 

Note: Weekdays are printed on dial in abbreviations of 

three languages.

Twenty-four hour (IHT/T, GPT/T) minimum switching 

time: 15 minutes. 

Seven day (IHT/W, GPT/W) minimum switching time: 

2 hours. 

To set ON/OFF times, move all tappets between 

ON and OFF times required to outer position i.e. to 

set ON at 8.00 a.m. and OFF at 11.00 a.m. move all 

tappets to outer position (see figure 2): Set any other 

ON/OFF times in a similar manner. 