background image

(GRA-ASC-VENT) ASCENT ROOF VENT PACKING LIST

615

616

618

W04

Z02

22 3/4 in / 578 mm

22 3/4 in / 578 mm

19 11/16 in / 500 mm

CONNECTOR FOR 603

SCREWS FOR ROOF VENT

GRAPHIC              PART NAME          SIZE/LOCATION      QUANTITY

1

1

2

2

5

   

G R E E N H O U S E S

GRANDIO

2015 GRANDIO ASCENT ADDITIONAL ROOF VENT KIT

FOR NEW AND EXISTING GREENHOUSE CUSTOMERS

© 2013 Grandio Greenhouses, Backyard Living Source Inc. All rights reserved

2015 Manual Edition Extra Roof Vents for Ascent Greenhouses

HQC01

HQC02

Z04, S04/ML01

S04/ML01

603B

ROOF VENT ARM

ROOF VENT LATCH

ROOF VENT HARDWARE

COMBOS FOR 603B/W04

21 7/8 in / 555 mm

GRAPHIC              PART NAME         SIZE/LOCATION        QUANTITY

1

1

2 EACH

8

1

   

Summary of Contents for GRA-ASC-VENT

Page 1: ...O U S E S GRANDIO 2015 GRANDIO ASCENT ADDITIONAL ROOF VENT KIT FOR NEW AND EXISTING GREENHOUSE CUSTOMERS 2013 Grandio Greenhouses Backyard Living Source Inc All rights reserved 2015 Manual Edition Ex...

Page 2: ...he side with the doors See 1 2 Detach all J602B J602A and J601 end caps from the gutters on both front and back of your greenhouse as shown below Set aside the end caps and hardware in a safe place fo...

Page 3: ...CTIONS Clear Transparent Film Opal White Film Polycarbonate Panels Sun The UV Protected side is covered with clear film and must face toward the sun The side covered in white film will always face the...

Page 4: ...of the panel that should face outwards to the sun 1 5 You will need to cut 1 of the Y7 Panels which measure 22 3 4 x 58 1 8 to the dimensions of a Y8 Roof Vent Panel which is 22 3 4 x 19 1 8 See 1 6...

Page 5: ...middle for support do not place nearest the front or back as you will need a 602B support to keep in window vent in place Place directly across from each other for best cross draft ventilation see for...

Page 6: ...andle to the second and third pins of HQC02 Then attach HQC02 into 603C s track with S04 ML01 nuts and bolts see 603B 618 616 616 603C 616 Z04 HQC02 Y8 Y8 HQC01 Handle Inside view of 603B 603B 602B W0...

Page 7: ...fore gutters are in place You may want to place a piece of tape on the panel to prevent sliding as shown in the diagram once the panels are in place 1 14 Slide 610 Gutters into 609 s groove as shown i...

Page 8: ...ds of ridge to secure pressure fit end caps It is recommended to caulk any areas that may allow water penetration such as at the gutter end caps and at the base corners to seal against water as shown...

Reviews: