background image

Frequency 

433,92 MHz 

Transmission 

rolling code KeeLoq ® Microchip Technology) 

Number of keys 

Type of receiving module 

superheterodyne 

Sensitivity 

-115 dBm 

Power 

1xbatery 9V/ 6F22 (standard) or nickel metal hydride 

rechargeable NiMH 8.4V / 170mAh  

 

  Memory capacity  

 

500 transmitters  

 

Event log 

500 

Acoustic signaling 

Repeating signal 

the duration of signaling: 20s 

every 30s until cleared 

Dimension (mm) 

65*100*24 

Color 

black 

Compatibility 

any GE sender (except NRP 102K), retransmitter  

type RTS 100 

Operating range (m): 

from 150 to 800 depending on the transmiter* 

  Pager has acoustic signaling of low battery condition and their transmitters it conects.  

  Sold complete with antenna and belt clip. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TECHNICAL PARAMETERS  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating range 

USER MANUAL 

device type OBI 3SH PAGER

  

150 m 

Remotes type PUK 

300 m 

The hermetic PNH 201 

500 m 

Panic remote PUK 303 

800 m 

retransmiter RTS 100, remote controls high-range RNB and stationary transmitters type NRP 

 

 

The reported ranges refer to the open space (without any obstacles, when the pager and the transmitter can "see" each 

other). If between pager and transmitter are obstacles, there should be a reduction in the operating range respectively 

for:  wood and plaster of 5-20%, 20-40% brick, reinforced concrete by 40 - 80%. With the many obstacles we advise to 

use retransmitters or stronger remote controls. For metallic obstacles applying radio systems is not recommended.  

 

1.

 

 ON - Turn on/off the device. 

• 

start – hold  

C  

until the string ON appears. 

• 

stop –   hold 

C  

until the string OFF appears. 

 

Standby PAGER is indicated by the flashing LED.  

After switching PAGER performs a power supply test, the completion of which is indicated by switching on of all  

segment display. Procedures PROGRAM, EDIT and CLEAR must be performed after completion of the test power. 

 

2.

 

WORKING STATE. 

 

PAGER receive the signal from the programmed transmitter causes: switching sound signaling,  

Display programmed description of the transmitter (3.4) and briefly displays the number of memory cells  

PAGER under which the transmitter has been programmed. The signaling continues for 20s, then is recalled. 

 

 

• 

key 

- Viewing alarms 

• 

key       

C  

- Clearing alarms 

During the reset alarms first pressing

 

C  

cancels the audible signal, the second pressing deletes the record on 

the 

display 

and memory PAGER.

 

Page: 1 of 4 

 

Reviews:

Related manuals for OBI 3SH