addendum instructions

for solar appliance

please leaVe tHese instructions in tHe pocket proVided on 

tHe back of tHe front panel

an open Vented mains pressure Hot water 

supply appliance witH tHermal store 

designed specifically for use witH 

solar energy

tHese instructions must be read in 

conjunction witH tHe standard 

pulsacoil design, installation and serVicing 

instructions before installation

TM

benchmark

The code of practice for the installation,

commissioning & servicing of central heating systems

models

PCA 200 - SOL
PCA 220 - SOL  
PCA 240 - SOL  

   

    

 

Pulsa

Coil SOL

A - C L A S S

Summary of Contents for PCA 200 - SOL

Page 1: ...liance with thermal store designed specifically for use with solar energy these instructions must be read in conjunction with the standard PULSACOIL design installation and servicing instructions before installation TM benchmark Thecodeofpracticefortheinstallation commissioning servicingofcentralheatingsystems Models PCA 200 SOL PCA 220 SOL PCA 240 SOL PulsaCoil SOL A C L A S S ...

Page 2: ...06 CORGI operates a Self Certification Scheme for gas heating appliances These arrangements represent a change from the situation whereby compliance with the Building Regulations was accepted if the Benchmark Logbook was completed and this was then left on site with the customer With the introduction of a self certification scheme the Benchmark Logbook is being replaced by a similar document in th...

Page 3: ...eak tariff it is recommended that a time clock is fitted on the electrical supply to the off peak bottom immersion heater This should be set to charge the store overnight and allow the solar to replenish the store during the day A new appliance incorporating most of the solar equipment and controls will be available later this year The controls will be intelligent and under certain conditions will...

Page 4: ...ng Instruction Manual The extra wiring terminals shown above are not shown in the base manual and have been illustrated above for ease of understanding Their actual location is on the far right hand side of the din rail within the appliance situated above the top immersion heater see photo below for actual din rail postion T1 T2 T3 Additional wiring terminals for installer to connect 3rd party sol...

Page 5: ...ge Volumes Total litres 164 191 210 Solar litres 53 64 68 Heat loss factor kWh 24h 2 022 2 052 2 086 Temperature factor vessel heat loss 1 This flow rate is based on a 35ºC temperature rise and assumes that the recommended pressures and adequate flow are available at the appliance The actual maximum flow rate is regulated to a maximum of 26 litres minute 2 The temperature of hot water is also regu...

Page 6: ... and all relevant codes of practice and regulations in force at the time of installation That all necessary inlet controls and safety valves have been fitted correctly It has only been used for the storage of potable water supplied from the public mains Where appropriate the unit has been regularly maintained as detailed in the installation and service instructions 1 Domestic and Commercial Open V...

Page 7: ...ciated with a fiduciary relationship shall apply d the Purchaser s right to possess the goods shall cease forthwith upon the happening of any of the following events namely i if the Purchaser fails to make payment in full for the goods within the time stipulated in clause 4 hereof ii if the Purchaser not being a company commits any act of bankruptcy makes a proposal to his or her creditors for a c...