manualshive.com logo in svg
background image

01

INFINITY 220

Spa Collection

Rev.

01/2022

Infinity 220

Spa Collection

IT / EN

Manuale di preinstallazione

Pre-installation manual

REV. 01/2022

Содержание Infinity 220

Страница 1: ...01 INFINITY 220 Spa Collection Rev 01 2022 Infinity 220 Spa Collection IT EN Manuale di preinstallazione Pre installation manual REV 01 2022...

Страница 2: ...re si riserva il diritto di apportare in qualunque momento senza preavviso modifiche migliorative al prodotto The manufacturer reserves the right to make improvements to the products at any time witho...

Страница 3: ...eat exchanger option Freestanding preparazione della sede di installazione Freestanding preparation of the installation site Built in preparazione della sede di installazione Built in preparation of t...

Страница 4: ...urements and technical specifications Freestanding Semi incasso Semi Built in L azienda consiglia un carico a pavimento minimo di 450 kg m2 The manufacturer suggests a minimum floor load of 450 kg m2...

Страница 5: ...o 1 49 kW Absorbed power AIRPOOL version heater excluded Potenza assorbita versione WHIRLPOOL riscaldatore escluso 4 95 kW Absorbed power WHIRLPOOL version heater excluded Potenza assorbita versione C...

Страница 6: ...Electrical connection Locale dedicato per collegamento elettrico Room for the electrical connections Locale dedicato per collegamento elettrico Room for the electrical connections 40 Collegamento elet...

Страница 7: ...tion IT Scambiatore di calore Heat exchanger EN Capacit termica 108 000 KJ Thermal capacity Portata 6m3 h Flow rate Dimensioni dell attacco entrata uscita Size of water inlet outlet fitting Temperatur...

Страница 8: ...te alle norme elettriche Before preparing the basement check the sections on the hydraulic and electrical connections for positioning the connections correctly As a basement build a perfectly flat pla...

Страница 9: ...calculate the appropriate load for the installation site Prepare 1 A technical inspection compartment at least 50 cm wide on all sides of the spa This will make future maintenance or repairs easier 2...

Страница 10: ...The water connection must be dedicated exclusively to the spa it is not possible to connect other equipment to the same connection and carried out with new and never used hoses and couplings It is rec...

Страница 11: ...atore a resine cationiche addolcitore scegliendo il modello in base alla durezza dell acqua cause limescale that over time can cause damage to the walls of the spa the pipes the filter system as well...

Страница 12: ...ulti pole switch with a contact gap of at least 3 mm and a breaking capacity equal to 60A or in any case adequate for the absorption of the bathtub Controlled by a differential switch no larger than 3...

Страница 13: ...erruttori lampade etc nella zona circostante la minipiscina per una distanza di almeno 60 cm ed un altezza di 230 cm Local regulations prohibit any electrical installation plug sockets switches lamps...

Страница 14: ...h these directives is guaranteed by the following harmonised provisions Compatibilit elettromagnetica 2014 30 UE Electromagnetic compatibility La conformit a tale direttiva garantita dalle seguenti no...

Страница 15: ......

Страница 16: ...016 INFINITY 220 Spa Collection Rev 01 2022 Via Baite 12 E 31046 Oderzo TV Italy T 39 0422 7146 r a info glass1989 it www glass1989 it REV 01 2022...