background image

016_03

Installation, operating and
maintenance instructions

09/2009

ELECTRIC COOKERS

K2V · K4V

K4PFCE · K4VFCE · K4VFE

K6PFCE

K2P · K4P · K6P

K4PFE · K6PFE

OP2P · OP4P · OP6P

OP2V · OP4V

© COPYRIGHT 2004 GIGA GRANDI CUCINE SRL

Summary of Contents for K2P

Page 1: ...6_03 Installation operating and maintenance instructions 09 2009 ELECTRIC COOKERS K2V K4V K4PFCE K4VFCE K4VFE K6PFCE K2P K4P K6P K4PFE K6PFE OP2P OP4P OP6P OP2V OP4V COPYRIGHT 2004 GIGA GRANDI CUCINE SRL ...

Page 2: ... 7 Legal and technical requisites 7 Installation 7 Wiring 7 Unipotential 7 Using the appliance 7 Ignition 7 Cleaning and taking care of the appliance 8 What to do if not using the appliance for a long time 8 What to do if something goes wrong 8 Maintenance 8 WEEE Directive 9 Wiring diagrams 10 27 Warning 28 INDEX ...

Page 3: ...ons K2P 400 x 900 x 875 weight approx 63 kg K4PFE K4PFCE 800 x 900 x 875 weight approx 138 122 kg K6PFE K6PFCE 1200 x 900 x 875 weight approx 168 151 kg K4P 800 x 900 x 875 weight approx 111 kg K6P 1200 x 900 x 875 weight approx 131 kg ...

Page 4: ...016 03 Electric cookers 4 Dimensions K4VFE K4VFCE weight approx 134 118 kg K2V weight approx 62 kg K4V weight approx 108 kg ...

Page 5: ...016 03 Electric cookers 5 Dimensions OP4P weight approx 96 kg OP2P weight approx 52 kg OP6P weight approx 107 kg OP2V weight approx 50 kg OP4V weight approx 92 kg ...

Page 6: ... V 3 400 V 3N or 230 V 3 400 V 3N or 230 V 3 400 V 3N or 230 V 3 400 V 3N or 230 V 3 400 V 3N or 230 V 3 400 V 3N or 230 V 3 400 V 3N or 230 V 3 400 V 3N or 230 V 3 400 V 3N or 230 V 3 400 V 3N or 230 V 3 400 V 3N or 230 V 3 400 V 3N or 230 V 3 400 V 3N or 230 V 3 400 V 3N or 230 V 3 400 V 3N or 230 V 3 Lead wire Section 5 x 2 5 mm2 or 4 x 2 5 mm2 5 x 2 5 mm2 or 4 x 2 5 mm2 5 x 6 mm2 or 4 x 10 mm2...

Page 7: ...nection of the appliance from the mains Wiring When choosing the lead wire make sure it has the fol lowing characteristics it should be at least of the H07 RN F type and its section should be large enough for the ap pliance see Technical specifications and dimensions page 6 Two lead wires are needed for models with a vol tage of 230 V 3 AC The terminal boards are in the terminal box located undern...

Page 8: ...e disconnect from the mains Remove all the extractable parts from the oven and wash separately All steel parts should be washed in warm wa ter using a neutral detergent Avoid using abrasive or corrosive detergents which could damage the steel What to do if not using the appliance for a long time Thoroughly clean and dry the machine as described Disconnect the power supply What to do if something g...

Page 9: ...tre or returned to the reseller when buying a new equivalent item of equipment The user is responsible for delivering the unit at the end of its life to the appropriate collection facilities Failure to do so shall result in the user being subject to the penalties prescribed by the legislation in force on waste Suitable separated collection so that the unit no longer used can be sent off for enviro...

Page 10: ... B1 H1 P3 P1 P2 5 2 1 3 4 3 1 4 N2 400 V 3N 15 3 A 1 mA 2 3 6 5 4 3 2 1 0 R1 4000 w 2500 w 1500 w 1000 w 600 w 430 w B1 5 P3 P1 P2 2 1 3 3 4 N3 N1 N3 N1 230 V 26 7 A 1 2 3 230 V 3 26 7 A 1 2 3 L1 L2 N Line input terminal board Hotplate commutator Pilot lamp Hotplate mA B1 H1 R1 K2P OP2P ...

Page 11: ...A R1 2 B1 H1 P3 P1 P2 5 2 1 3 4 3 1 4 N2 R1 2 B1 H1 P3 P1 P2 5 2 1 3 4 3 1 4 N2 1 mA 2 3 4 L1 L2 L3 N 5 6 6 5 4 3 2 1 0 B1 5 P3 P1 P2 R1 4000 w 2500 w 1500 w 1000 w 600 w 430 w 2 1 3 3 4 N3 N1 N3 N1 N3 N1 N3 N1 230 V 3 38 2 A L1 L2 L3 1 m A 2 3 4 5 6 K4P OP4P Line input terminal board Hotplate commutator Pilot lamp Hotplate mA B1 H1 R1 ...

Page 12: ...1 H1 P3 P1 P2 5 2 1 3 4 3 1 4 N2 R1 2 B1 H1 P3 P1 P2 5 2 1 3 4 3 1 4 N2 R1 2 B1 H1 P3 P1 P2 5 2 1 3 4 3 1 4 N2 1 mA 2 3 4 L1 L 2 L 3 N 5 6 6 5 4 3 2 1 0 B1 5 P3 P1 P2 R1 4000 w 2500 w 1500 w 1000 w 600 w 430 w 2 1 3 3 4 N3 N1 N3 N1 N3 N1 N3 N1 N3 N1 N3 N1 230 V 3 53 5 A L1 L 2 L 3 1 m A 2 3 4 5 6 K6P OP6P Line input terminal board Hotplate commutator Pilot lamp Hotplate mA B1 H1 R1 ...

Page 13: ... 6 P6 P5 P2 7 2 1 3 4 F2 1 3 5 2 4 6 1 3 5 2 4 6 R3 R2 H1 H2 230 V 3 51 A L1 L 2 L 3 1 m A 2 3 4 5 6 1 3 5 2 4 6 R3 R2 3 2 1 0 B3 5 P3 P5 P4 P2 P6 6 7 2 1 3 4 N3 N1 N3 N1 N3 N1 N3 N1 6 5 4 3 2 1 0 B1 5 P3 P1 P2 2 1 3 3 4 R1 4000 w 2500 w 1500 w 1000 w 600 w 430 w K4PFE Line input terminal board Hotplate commutator Switch EGO Commutateur EGO Thermostat EGO Pilot lamp Pilot lamp voltage Hotplate Ove...

Page 14: ... P1 P2 2 1 3 3 4 R1 4000 w 2500 w 1500 w 1000 w 600 w 430 w K6PFE 2 H1 P3 P1 P2 5 2 1 3 4 3 1 4 N2 N3 N1 2 P3 P1 P2 5 2 1 3 4 3 1 4 N2 N3 N1 P1 1 P2 2 P3 3 P4 4 F1 2 P3 P1 P2 5 2 1 3 4 3 1 4 N2 N3 N1 2 P3 P1 P2 5 2 1 3 4 3 1 4 N2 N3 N1 2 P3 P1 P2 5 2 1 3 4 3 1 4 N2 N3 N1 R2 2 P3 P1 P2 5 2 1 3 4 3 1 4 N2 N3 N1 2 3 4 5 6 B3 P3 5 P4 6 P6 P5 P2 7 2 1 3 4 F2 L1 L 2 L 3 R1 R1 R2 R2 R1 1 3 5 2 4 R3 R2 1 ...

Page 15: ... P3 P1 P2 2 1 3 3 4 R1 4000 w 2500 w 1500 w 1000 w 600 w 430 w K6PFE 2 H1 P3 P1 P2 5 2 1 3 4 3 1 4 N2 N3 N1 2 P3 P1 P2 5 2 1 3 4 3 1 4 N2 N3 N1 P1 1 P2 2 P3 3 P4 4 F1 2 P3 P1 P2 5 2 1 3 4 3 1 4 N2 N3 N1 2 P3 P1 P2 5 2 1 3 4 3 1 4 N2 N3 N1 2 P3 P1 P2 5 2 1 3 4 3 1 4 N2 N3 N1 R2 2 P3 P1 P2 5 2 1 3 4 3 1 4 N2 N3 N1 2 3 4 5 6 B3 P3 5 P4 6 P6 P5 P2 7 2 1 3 4 F2 L1 L 2 L 3 R1 R1 R2 R2 R1 1 3 5 2 4 R3 R2...

Page 16: ...d B1 Double power plate energy regulator H1 Pilot lamp H2 Residual heat pilot lamp R1 1000 2500 W cooking plate K2V OP2V R2 P1 50 55 P2 S1 S2 40 2 4 H1 2 H S B1 H2 H2 R1 P1 50 55 P2 S1 S2 40 2 4 H1 2 H S B1 1 mA 2 3 4 L1 L2 L3 N 5 6 400 V 3N PE R2 1500 3400 W cooking plate ...

Page 17: ...S2 40 2 4 H1 2 H S B1 H2 H2 R1 P1 50 55 P2 S1 S2 40 2 4 H1 2 H S B1 1 mA 2 3 4 L1 L2 L3 5 6 230V 3 PE mA Line arrival terminal board B1 Double power plate energy regulator H1 Pilot lamp H2 Residual heat pilot lamp R1 1000 2500 W cooking plate R2 1500 3400 W cooking plate ...

Page 18: ...uble power cooking plate K4V OP4V P1 50 55 P2 S1 S2 10 2 1 P1 P2 5 S 4 50 17 P1 50 55 P2 S1 S2 10 2 1 P1 P2 5 S 4 50 17 N L1 L2 L3 mA H1 B2 H1 B1 H1 B2 H1 B1 R2 H2 1 2 3 4 R1 4 R2 R1 2 1 3 T 4 4A 2 2 4 4 4A 2 2 4 400 V 3N AC B2 B1 B2 B1 H1 H1 H1 H1 Terminal 4a Terminal 4 Terminal 2 Residual heat lamps Color cables Color cables Color cables Color cables Blue section 1 5 mm2 White section 1 5 mm2 Re...

Page 19: ...V 3 AC B2 B1 B2 B1 H1 H1 H1 H1 mA Line arrival terminal board B1 Single power plate energy regulator B2 Double power plate energy regulator H1 Pilot lamp H2 Residual heat pilot lamp R1 1800 W cooking plate R2 1000 2500 W double power cooking plate Terminal 4a Terminal 4 Terminal 2 Residual heat lamps Color cables Color cables Color cables Color cables Blue section 1 5 mm2 White section 1 5 mm2 Red...

Page 20: ...1 H1 B1 K4PFCE 6 5 4 3 2 1 0 4000 w 2500 w 1500 w 1000 w 600 w 430 w B1 5 P3 P1 P2 2 1 3 3 4 R1 2 1 1 2 3 4 P1 P2 P3 P4 P5 P6 P7 P8 5 6 7 8 B3 H1 H2 MV RV RS RC RG F1 9 8 7 6 5 4 3 2 1 0 B1 8 7 6 5 4 3 2 1 P8 P7 P6 P5 P4 P3 P2 P1 Line imput terminal board Hot plate commutator Switch Thermostat Pilot lamp Pilot lamp voltage Hot plate 4000 W Ceiling element Grill element Floor element Fan element Fa...

Page 21: ...1 H1 B1 H1 B1 6 5 4 3 2 1 0 4000 w 2500 w 1500 w 1000 w 600 w 430 w B1 5 P3 P1 P2 2 1 3 3 4 R1 2 1 1 2 3 4 P1 P2 P3 P4 P5 P6 P7 P8 5 6 7 8 B3 H1 H2 MV RV RS RC RG F1 9 8 7 6 5 4 3 2 1 0 B1 8 7 6 5 4 3 2 1 P8 P7 P6 P5 P4 P3 P2 P1 Line imput terminal board Hot plate commutator Switch Thermostat Pilot lamp Pilot lamp voltage Hot plate 4000 W Ceiling element Grill element Floor element Fan element Fan...

Page 22: ... 1 2 3 4 4 3 R1 R1 R1 R1 R1 H1 B1 H1 B1 H1 B1 H1 B1 H1 B1 H1 B1 K6PFCE 6 5 4 3 2 1 0 4000 w 2500 w 1500 w 1000 w 600 w 430 w B1 5 P3 P1 P2 2 1 3 3 4 R1 9 8 7 6 5 4 3 2 1 0 B1 8 7 6 5 4 3 2 1 P8 P7 P6 P5 P4 P3 P2 P1 2 1 1 2 3 4 P1 P2 P3 P4 P5 P6 P7 P8 5 6 7 8 B3 H1 H2 MV RV RS RC RG F1 Line imput terminal board Hot plate commutator Switch Thermostat Pilot lamp Pilot lamp voltage Hot plate 4000 W Ce...

Page 23: ...5 2 1 1 2 3 4 4 3 R1 R1 R1 R1 R1 H1 B1 H1 B1 H1 B1 H1 B1 H1 B1 H1 B1 6 5 4 3 2 1 0 4000 w 2500 w 1500 w 1000 w 600 w 430 w B1 5 P3 P1 P2 2 1 3 3 4 R1 2 1 1 2 3 4 P1 P2 P3 P4 P5 P6 P7 P8 5 6 7 8 B3 H1 H2 MV RV RS RC RG F1 9 8 7 6 5 4 3 2 1 0 B1 8 7 6 5 4 3 2 1 P8 P7 P6 P5 P4 P3 P2 P1 Line imput terminal board Hot plate commutator Switch Thermostat Pilot lamp Pilot lamp voltage Hot plate 4000 W Ceil...

Page 24: ... B2 H1 B1 R2 H3 1 2 3 4 R1 4 R2 R1 2 1 3 4 4A 2 2 4 4 4A 2 2 4 400 V 3N AC B2 B1 B2 B1 H1 H1 H1 H1 2 1 1 2 3 4 P1 P2 P3 P4 P5 P6 P7 P8 5 6 7 8 B3 H1 H2 MV RS RV F1 9 8 7 6 5 4 3 2 1 0 B1 8 7 6 5 4 3 2 1 P8 P7 P6 P5 P4 P3 P2 P1 1 mA 2 3 4 L1 L 2 L 3 N 5 6 RC RG B3 Conmutador horno F1 Termostato H3 Bombilla espía calor residual RC Resistencia cielo RG Resistencia grill RS Resistencia suela RV Resist...

Page 25: ...oite a bornes B1 Régulateur d énergie plaque une seule puissance B2 Régulateur d énergie plaque double puissance H1 Lampe temoin H2 Lampe temoin tension R1 Plaque cuisson 1800 W R2 Plaque cuisson double puissance 1000 2500 W B3 Commutateur four F1 Thermostat H3 Temoin lumineux chaleur résiduelle RC Résistance supérieur four RG Résistance gril four RS Résistance sole four RV Résistance ventilateur ...

Page 26: ...5 S 4 50 17 H1 B2 H1 B1 H1 B2 H1 B1 R2 H3 1 2 3 4 R1 4 R2 R1 2 1 3 4 4A 2 2 4 4 4A 2 2 4 400 V 3N AC B2 B1 B2 B1 H1 H1 H1 H1 1 mA 2 3 4 L1 L 2 L 3 N 5 6 B3 Switch oven B4 Commutator oven F1 Thermostat F2 Security thermostat oven H3 Residual heat indicator light P1 P4 P3 P2 1 2 3 4 B4 P3 P4 P6 P2 P5 5 6 7 2 1 1 2 3 4 5 1 2 3 4 5 3 4 R2 R3 H1 H2 B3 3 2 1 0 B3 5 P3 P5 P4 P2 P6 6 7 2 1 3 4 F1 F2 Termi...

Page 27: ...2 R3 H1 H2 B3 F1 F2 mA Terminal board B1 Single power plate energy regulator B2 Double power plate energy regulator H1 Green indicator light H2 Yellow indicator light R1 Heating element 1800 W R2 Heating element double power 1000 2500 W R3 Lower and upper heating elements oven B3 Switch oven B4 Commutator oven F1 Thermostat F2 Security thermostat oven H3 Residual heat indicator light Terminal 4a T...

Page 28: ...AL PRODUCT IMPRO VEMENT THE MANUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY THE MANUFACTURER CANNOT BE HELD RESPONSI BLE IF THE INSTRUCTIONS CONTAINED IN THIS MA NUAL ARE NOT OBSERVED GIGA GRANDI CUCINE S r l Via Pisana 336 Loc Olmo 50018 SCANDICCI FI ITALY Tel 39 055 722 33 11 linee r a Fax 39 055 7310 056 www gigagrandicucine it info gigagrandidicucine it ...