background image

009_03

Instructions for installation,
use and maintenance

09/2015

© COPYRIGHT 2004 GIGA GRANDI CUCINE SRL

GAS FRYTOP

SKT1G/GC/GR · SKT2G/GC/GR · SKT2G2/GC2/GR2/GLR

SKT3G/GC/GLR · SKT40G/GC/GR · SKT60G/GC/GR

SKT60G2/GC2/GR2/GLR · SKT80G/GC/GLR

CFTG1/1C/1R · CFTG2/2C/2R/2LR · CFTG22/2C2/2R2/2LR

CFTG3/3C/3R/3LR · CFTG4/4C/4R · CFTG6/6C/6R

CFTG62/6C2/6R2/6LR · CFTG8/8C/8R/8LR

TT1G/GC/GR · TT2G/GC/GR · TT2G2/GC2/GR2/GLR

TT3G/GC/GLR · TT40G/GC/GR · TT60G/GC/GR

TT60G2/GC2/GR2/GLR · TT80G/GC/GLR

Summary of Contents for CFTG1

Page 1: ...2G GC GR SKT2G2 GC2 GR2 GLR SKT3G GC GLR SKT40G GC GR SKT60G GC GR SKT60G2 GC2 GR2 GLR SKT80G GC GLR CFTG1 1C 1R CFTG2 2C 2R 2LR CFTG22 2C2 2R2 2LR CFTG3 3C 3R 3LR CFTG4 4C 4R CFTG6 6C 6R CFTG62 6C2 6R2 6LR CFTG8 8C 8R 8LR TT1G GC GR TT2G GC GR TT2G2 GC2 GR2 GLR TT3G GC GLR TT40G GC GR TT60G GC GR TT60G2 GC2 GR2 GLR TT80G GC GLR ...

Page 2: ...CHARACTERISTICS 009_03 GAS FRY TOP 2 20 Supplied by Date Customer Service FAX e mail ...

Page 3: ... 1 13 Replacement of burner pilot injector 13 5 1 14 Adjusting the pilot burner fry top 2 controls 600 13 5 1 15 Setting reduced capacity power 14 5 2 Maintenance 14 5 3 Replacing parts 14 5 3 1 Gas cock 14 5 3 2 Gas valve 14 5 3 3 Thermocouple 14 5 3 4 Plug 14 5 3 5 Plug fry top 2 controls 600 14 6 Instructions for use 15 6 1 Safety cleaning and repair rules 15 6 2 Start up smooth and grooved pla...

Page 4: ...T1GR SKT40GR 30 40 40 30 270 300 G T 80 1 35 2 13 5 1 131 320 205 5 400 52 510 93 104 G 35 2 13 5 1 655 TT1G TT1GC TT40G TT40GC TT1GR TT40GR 30 40 40 30 270 300 G T 80 1 80 2 13 5 1 210 320 205 5 400 97 510 93 104 G 80 2 13 5 1 700 G T Gas connection 1 2 Data plate ...

Page 5: ...2GC2 SKT60G SKT60G2 SKT60GC SKT60GC2 300 300 40 40 30 270 300 G T 80 1 35 2 13 5 1 130 520 205 5 600 52 510 93 104 G 35 2 13 5 1 655 104 G 35 2 13 5 1 655 SKT2GLR SKT60GLR TT2G TT2G2 TT2GC TT2GC2 TT60G TT60G2 TT60GC TT60GC2 SKT2GR SKT2GR2 SKT60GR SKT60GR2 TT2GR TT2GR2 TT60GR TT60GR2 104 G 80 2 13 5 1 700 TT2GLR TT60GLR G T Gas connection 1 2 Data plate ...

Page 6: ... 35 2 13 5 1 130 720 205 5 800 52 510 93 G 35 2 13 5 1 655 TT3G TT3GC TT80G TT80GC TT3GLR TT80GLR 300 200 300 40 40 30 270 300 G T 80 1 80 2 13 5 1 210 720 205 5 800 97 510 93 G 80 2 13 5 1 700 SKT3G SKT3GC SKT80G SKT80GC SKT3GLR SKT80GLR G T Gas connection 1 2 Data plate ...

Page 7: ...1 97 510 93 G 300 300 875 52 5 52 5 13 5 1 98 2 140 465 220 50 210 495 205 5 G 104 600 280 2 97 510 93 G 280 2 700 G 104 T CFTG1 CFTG1C CFTG4 CFTG4C CFTG1R CFTG4R CFTG2 CFTG22 CFTG2C CFTG2C2 CFTG6 CFTG62 CFTG6C CFTG6C2 280 2 700 G 104 CFTG2LR CFTG6LR CFTG2R CFTG2R2 CFTG6R CFTG6R2 G T Gas connection 1 2 Data plate ...

Page 8: ...AS FRY TOP 8 20 300 300 200 875 52 5 52 5 13 5 1 98 2 140 465 220 270 695 205 5 G 800 280 1 97 510 93 G 280 2 700 G T CFTG3 CFTG3C CFTG8 CFTG8C CFTG3LR CFTG8LR 280 2 700 G CFTG3R CFTG8R G T Gas connection 1 2 Data plate ...

Page 9: ...C2 G6R2 G6LR SKT3G GC GLR TT3G GC GLR CFTG3 G3C G3R G3LR SKT80G GC GLR TT80G GC GLR CFTG8 G8C G8R G8LR Version Gas Fry Top Varipan Gas Fry Top Varipan Gas Fry Top Varipan Gas Fry Top Varipan Gas Fry Top Varipan Gas Fry Top Varipan Gas Fry Top Varipan Gas Fry Top Varipan Gas Fry Top Varipan Gas Fry Top Varipan Gas Fry Top Varipan Gas Fry Top Varipan Gas Fry Top Varipan 2 separate cooking areas Gas ...

Page 10: ...kW kW No of nozzles pilot burner G20 G30 G31 15 15 36 19 11 5 3 2 4 15 15 225 adjustable 150 90 36 19 17 8 5 3 7 15 15 2 x 36 2 x 19 22 5 3 5 3 10 6 2 4 2 4 4 8 SKT1G GC GR SKT40G GC GR TT1G GC GR TT40G GC GR CFTG1 G1C G1R CFTG4 G4C G4R 175 adjustable 115 70 SKT2G GC GR SKT60G GC GR TT2G GC GR TT60G GC GR CFTG2 G2C G2R CFTG6 G6C G6R SKT2G2 GC2 GR2 GLR SKT60G2 GC2 GR2 GLR TT2G2 GC2 GR2 GLR TT60G2 G...

Page 11: ...6R2 G6LR SKT3G GC GLR TT3G GC GLR CFTG3 G3C G3R G3LR SKT80G GC GLR TT80G GC GLR CFTG8 G8C G8R G8LR have two separate grilling areas on the plate Each area has itsown temperature controls Warning For model CFTG4 4C 4R and CFTG1 1C 1R if this model is going to be mounted on its own it must be fixed to the floor Fixing accessories are included The appliance should be fitted following the indications ...

Page 12: ... gauge hose once measurement is complete replace the screw and do a seal check using a leak detector spray 5 1 4 Power check with volumetric method Using a gas meter and a stopwatch you can read the volume of gas output per time unit The correct volume corresponds to the value E expressed in litres hour l h or litre minute l min The following formula is used to calculate the value of E It is impor...

Page 13: ...1 To make changing the injector easier loosen screw pos 39 fig 4 to push the air adjustment sleeve back After fitting the injector reset primary air distance A see TECH NICAL DATA table 1 After the replacement check the seal using a leack detetctor spray 5 1 12 Replacement of burner injector fry top 2 controls 600 To change injector pos 30 fig 5 pull out the fat tray and loosen the fixing screws h...

Page 14: ...as described in paragraph 5 1 6 Operation control 5 3 Replacing parts All parts must be replaced by authorized technicians only To replace the following parts first remove all the control knobs and control panel after loosening the fixing screws then extract the ignition wire 5 3 1 Gas cock Loosen the gas piping pos 21 16 17 18 fig 3 and thermocouple hoses then loosen the fixing screws and insert ...

Page 15: ...cloth 6 2 1 Lighting pilot burner Check that the fat tray is in place Press the knob pos 4 fig 8 and turn to the left as far as Keep the knob pressed down while repeatedly pressing the piezo ignition button pos 6 fig 8 until the pilot flame catches you can see through aperture pos 10 fig 8 on the control panel Keep the knob pressed down for another 15 20 seconds if the pilot flame goes out after t...

Page 16: ...ar For this reason a service agreement contract is recommended 6 7 Recommendations for the treatment of stainless steel industrial kitchens 6 6 1 Useful information on stainless steel Industrial kitchens are generally made of stainless steel having the following material codes 1 4016 or 1 4511 magnetizable chromed steels 1 4301 1 4401 and 1 4571 non magnetizable chromed steels Chromed steels have ...

Page 17: ...ns 17 20 6 7 3 The 2002 96 EC WEEE Directive information to users This informational note is meant only for owners of equipment marked with the symbol shown in fig A on the adhesive label featuring the technical specifica tions applied on the actual product the label also giving the serial number This symbol indicates that the product is classified according to the regulations in force as an item ...

Page 18: ...009_03 GAS FRY TOP 18 20 NOTES ...

Page 19: ...009_03 GAS FRY TOP 19 20 NOTES ...

Page 20: ...idicucine it WARNING THE MANUFACTURER CANNOT BE HELD RESPONSIBLE FOR ANY INACCURACIES IN THIS BOOKLET DUE TO COPYING OR PRINTING ERRORS DUE TO ITS POLICY OF CONTINUAL PRODUCT IMPROVEMENT THE MANUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY THE MANUFACTURER CANNOT BE HELD RESPONSIBLE IF THE INSTRUCTIONS CONTAINED IN THIS MANUAL ARE NOT OBSERVED ...

Reviews: