background image

Pos: null /BA_Module/BA_AA  Deckblatt/BAAA000001_M003 @ 17\mod_1444211755814_28.docx @ 891110 @  @ 1 

 

 

 

 

 

Installation Instructions

 

ELEKTROMAT 
SI 100.24-55,00

 

Model: 10003286 10011

 

 

 
 
 
 
 
 
 
 
 

 

-en- 

 

Status: 06.03.2020

 

Pos: null /BA_Module/BA_Seitenumbruch @ 0\mod_1190719383361_0.docx @ 550 @  @ 1 

 

 

Summary of Contents for 10003286 10011

Page 1: ...Deckblatt BAAA000001_M003 17 mod_1444211755814_28 docx 891110 1 Installation Instructions ELEKTROMAT SI 100 24 55 00 Model 10003286 10011 en Status 06 03 2020 Pos null BA_Module BA_Seitenumbruch 0 mod...

Page 2: ...BACA000001_M002 15 mod_1416821436083_28 docx 864410 1 GfA ELEKTROMATEN GmbH Co KG Wiesenstra e 81 D 40549 D sseldorf www gfa elektromaten de info gfa elektromaten de Pos null BA_Module BA_Seitenumbru...

Page 3: ...Limit switch connection 14 9 Emergency manual operation emergency hand crank 15 10 Completion of commissioning testing 17 11 Declaration of incorporation Declaration of conformity 20 Pos null BA_Modu...

Page 4: ...t of the manufacturer Otherwise the Manufacturer s Declaration shall be rendered null and void Safety information Installation and initial operation tasks are to be performed by trained skilled fitter...

Page 5: ...ting current 6 90 A Operating frequency 50 Hz Power factor cos 0 78 Maximum movement per hour 20 h 1 Hand forces 206 N Class of protection IP 65 Limit switch range maximum revolutions of output shaft...

Page 6: ...and transmission elements must not be exceeded even for maximum holding torques or locking torques refer to technical data Connection elements Self locking connection elements with a minimum strength...

Page 7: ...7 Mounting Two elongated holes are provided for mounting Vertical installation is possible only when an additional torque mount is used...

Page 8: ...ons of the door manufacturer must also be observed during installation Warning Potential injury or danger to life During installation be sure to use a lifting device that has a sufficient load carryin...

Page 9: ...t Version Tighten all connection elements M16 to 175 Nm Install all other connection elements according to the specifications of the door manufacturer Version Raise the pedestal bearing Install the to...

Page 10: ...ve unit Version Tighten all connection elements M16 to 175 Nm Install all other connection elements according to the specifications of the door manufacturer Pos null BA_Module BA_Seitenumbruch 0 mod_1...

Page 11: ...e cables are de energised Observe the applicable regulations and standards Make a proper electrical connection Use suitable tools Performing electrical installation Remove the cover Insert the motor p...

Page 12: ...11_M001 0 mod_1194954682399_28 docx 2518 1 1 5 Limit switch adjustment The adjustment of the final limit positions OPEN and CLOSE is described in the instructions for the door control panel Pos null B...

Page 13: ...on G1 Rectifier EGR M1 Motor X13 Motor plug Y1 Brake Pos null BA_Module BA_MC Alternativer Motoranschluss BAMC011002_M001 0 mod_1271681188023_28 docx 518490 1 1 7 Alternative motor connection G1 Recti...

Page 14: ...26757070_28 docx 963 1 1 8 Limit switch connection F10 Thermal contact S10 Manual operation X12 DES connection 1 Safety circuit 2 Channel B RS485 3 Ground 4 Channel A RS485 5 Safety circuit 6 Supply n...

Page 15: ...dopt a secure position For drive units with brake the emergency manual operation must be carried out against the closed brake Warning Danger of the door dropping If you need to apply more than the per...

Page 16: ...e crank and turn until it engages Open or close by turning the crank After use the crank may be attached to the drive unit Attach as illustrated Pos null BA_Module BA_Seitenumbruch 0 mod_1190719383361...

Page 17: ...afety brake is triggered to prevent the door from dropping The gearbox stalls Releasing the stalling may cause the door to drop Block the door for pedestrians and vehicles Do not release the stalling...

Page 18: ...its equipment The manufacturer s specifications must be observed The brake release for doors without counter balancing may only be used in the CLOSE final limit position Warning Injury or danger to li...

Page 19: ...ire drive unit Note Have the drive checked annually by a specialist Shorter inspection interval for frequently used doors Observe the applicable regulations and standards Ende der Liste f r Textmarke...

Page 20: ...m in which it has been installed complies with the provisions of the above mentioned directives Authorised representative to compile the technical documents is the undersigned D sseldorf 10 08 2018 St...

Reviews: