background image

Instruction Manual

for

PH3 Controller

#510-3300

Summary of Contents for PH3 Controller 510-3300

Page 1: ...Instruction Manual for PH3 Controller 510 3300 ...

Page 2: ...This symbol indicates the possibility of being hurt or generating material damages if this product is operated improperly regardless of this instruction Introduction The Gesswein PH3 Controller is a compact variable speed power pack that can run any of the Power Hand 3 and PH2X rotary reciprocating or belt sanding handpieces Backed by a full one year warranty Two output stations on the Standard Co...

Page 3: ...eaned with a well wrung cloth dipped in a detergent and water solution and then wipe dry Inspect after each use If anything unusual is detected please contact your supplier before using again Periodical inspection is recommended every 1 or 2 years for safely and efficiently Please consult your supplier for this service Safety System Circuit Breaker The Circuit Breaker will temporarily stop power s...

Page 4: ...em if applicable and description Part Description 1 Power Switch 2 Station A Output Jack 3 Station A Selection Lamp 4 Station A Selection Button 5 Speed Control Knob 6 Station B Selection Button 7 Station B Selection Lamp 8 Station B Output Jack 9 Rotational Speed Display 10 Handpiece Holder 11 Start Stop Lamp 12 Start Stop Button 13 Load Indicator 14 Forward Lamp 15 Rotation Selection Button 16 R...

Page 5: ...the speed while using the Foot Controller In that case Start Stop Lamp 11 blinks Please push the Start Stop Button 12 again or Hand Button B to release it or step on the pedal once Low speed rotation If after not using for some time the Handpiece won t operate at low speed run at high speed for ten seconds This will remove oxides that may have formed on the motor commutator Load Indicator Load Ind...

Page 6: ...sent setting Effective and No Effect in Hand Button B are switched as LED of Load Indicator 13 is lit and turned off After setting it it becomes usual operation by turning on Power Switch 1 again How To Change Fuses There are fuses in Inlet with Fuseholder 20 Fuses can be changed by removing a lock on both sides and pulling out the fuse holder Please use correct fuse according to the plug Handpiec...

Page 7: ...ent selection PH3 controller Six motors three high torque two standard and one high speed A selection of 8 heads Two reciprocating profilers One side to side profiler Belt Sander Power Hand 3 controllers and handpieces combine to create the most versatile finishing system in the industry offering rotary profiling and belt sanding action 891 3552 1113 ...