background image

 

 

Instruction Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

from software version 1.0   

 

(instruction version 1.3) 

 

email: [email protected] 

Internet: http://www.GLP.de 

Summary of Contents for Junior Scan 2

Page 1: ...Instruction Manual from software version 1 0 instruction version 1 3 email service glp de Internet http www GLP de ...

Page 2: ...GLP German Light Production V1 3 1 ...

Page 3: ...cial Functions 6 3 2 1 Reset Function 6 3 2 2 Sound Function 6 3 2 3 Lamp ON OFF 7 3 2 4 Temperature Control 7 3 2 5 Invert PAN Tilt 7 4 DMX Channel Selection DMX Protocol 8 5 Changing the lamp 11 5 1 Safety regulations 11 5 2 Realize the Lamp Change 11 6 Changing the Gobos 12 6 1 Safety Regulations 12 6 2 Realize the Gobo Change 12 7 Maintenance and Cleaning the J JU UN NI IO OR R S SC CA AN N 2 ...

Page 4: ...GLP German Light Production V1 3 3 1 Description of Device Illustration 1 1 ...

Page 5: ...ly sure it is cold Danger of BURNING 5 Never look directly into the beam of the lamp You risk injury of your retina and blindness 6 Pay attention of the maximum lamp operation time You have to change it if the lamp shows any deformations or damages The same is with all glass components color filters lenses and mirrors 7 To allow a secure operation follow also the Installation guide described in ch...

Page 6: ...N N 2 2 Install a safety wire through the handle that can hold at least 10 times the weight of the fixture 2 3 Connectors 2 3 1 AC Connectors 230 Volt 50 Hz EU model or 120 Volt 60 Hz US model Please see printing on the case for the right power supply 2 3 2 DMX DMX 512 Standard input output Pin 3 Pin 2 Ground Pin 3 The DMX Address starts at 001 Please see printing on the case for the right Pin usa...

Page 7: ...function can also be started via the DMX signal Select a DMX value between 250 and 255 for longer than 3 seconds in the Special Channel No 9 3 2 2 Sound Function This function allows you to run a stand alone audio program For activating please use the following procedure Press and hold down the right display button first digit while switching on the J JU UN NI IO OR R S SC CA AN N 2 2 The display ...

Page 8: ... Shutter to a value between 254 255 3 2 4 Temperature Control If the inside temperature of the unit exceeds an certain value e g in case of blocked fans the lamp of the J JU UN NI IO OR R S SC CA AN N 2 2 will be automatically switched off After solving the problem the lamp can be started once again 3 2 5 Invert PAN Tilt This function allows you to invert the PAN Tilt movement Press and hold down ...

Page 9: ... 39 24 27 15 Lavender V98349 40 43 28 2B 16 Half Color 6 44 47 2C 2F 18 Magenta M56339 48 51 30 33 19 Half Color 7 52 55 34 37 21 Light Blue B6467 56 59 38 3B 22 Half Color 8 60 63 3C 3F 24 Fire 00819 64 67 40 43 25 Half Color 9 68 71 44 47 27 Turquoise C4700 72 75 48 4B 29 Half Color 10 76 79 4C 4F 30 Pink M6336 80 83 50 53 32 Half Color 11 84 87 54 57 33 Canary Y89312 88 91 58 5B 35 Half Color 1...

Page 10: ... Gobo 4 32 39 20 27 15 Gobo 5 40 47 28 2F 18 Gobo 6 48 55 30 37 21 Gobo 7 56 63 38 3F 24 Gobo 8 64 71 40 47 27 Gobo 9 72 79 48 4F 30 Gobo 10 80 87 50 57 33 Gobo 11 88 95 58 5F 36 Gobo 12 96 103 60 67 40 Gobo 13 104 111 68 6F 42 Gobo 14 112 119 70 77 45 Gobo 15 120 127 78 7F 48 Gobo 16 128 135 80 87 52 Gobo 17 136 143 88 8F 55 Gobo 18 144 151 90 97 58 Gobo 19 152 159 98 9F 60 music Gobo chaser slow...

Page 11: ... 1F 12 TILT 32 63 20 3F 13 25 PAN TILT 64 95 40 5F 26 37 PAN TILT inverse 96 127 60 7F 38 50 Circle 128 159 80 9F 51 62 Circle inverse 160 191 A0 BF 63 75 lying eight 192 223 C0 DF 76 87 random movement 224 255 E0 FF 88 100 8 Laser Laser OFF 0 15 00 0F 0 3 Laser flashes random 16 31 10 1F 9 Laser Audio controlled 32 47 20 2F 16 Laser blinking slow fast 48 127 30 7F 17 49 Laser blinking slow fast 1...

Page 12: ... Please see also Illustration 1 1 on page 3 1 Open the two Phillips screws on the bottom of the case 2 Pull out the lamp holder sheet including the lamp securely 3 Remove the old broken lamp 4 Put in the new lamp securely in reverse order Use only the originally lamp type Do not touch the new lamp with bare fingers 5 Apply the lamp holder sheet back again into the shaft 6 Close the two Phillips sc...

Page 13: ...ug Wait at least 20 minutes after the last operation to cool down the fixture Before you put the J JU UN NI IO OR R S SC CA AN N 2 2 into operation close the casing otherwise your retina can be hurt 6 2 Realize the Gobo Change 1 Open the J JU UN NI IO OR R S SC CA AN N 2 2 as described before in chapter 5 on page 11 2 Take out the Gobo by holding it with your fingers 3 Insert the new Gobo and snap...

Page 14: ... under no circumstances should alcohol or solvents be used The inside optical system should be maintained only by authorized persons Please contact your local dealer 7 1 Safety Regulations Pull out the main plug Wait at least 20 minutes after the last operation to cool down the fixture Before you put the J JU UN NI IO OR R S SC CA AN N 2 2 into operation close the casing otherwise your retina can ...

Page 15: ...irror Stand alone music controlled Weight 8 5 kg Measures 540 x 310 x 220 mm Nr Color 1 Dark Blue B01 2 Dark Green G01 3 Light Yellow Y0200 4 Bright Blue B2879 5 Lavender V98349 6 Magenta M56339 7 Light Blue B6467 8 Fire 00819 9 Turquoise C4700 10 Pink M6336 11 Canary Y89312 12 Golden Amber O5921 13 Red R9926 14 Italien Blue C45370 15 Green G28389 A Bright Blue B2879 B Canary Y89312 C Magenta M563...

Page 16: ...GLP German Light Production V1 3 15 ...