background image

 

 

 
 

S

S

i

i

l

l

v

v

e

e

r

r

 

 

S

S

h

h

i

i

e

e

l

l

d

d

 

 

P

P

o

o

w

w

e

e

r

r

 

 

M

M

a

a

n

n

a

a

g

g

e

e

r

r

 

 

S

S

i

i

l

l

v

v

e

e

r

r

 

 

S

S

h

h

i

i

e

e

l

l

d

d

 

 

P

P

o

o

w

w

e

e

r

r

 

 

M

M

a

a

n

n

a

a

g

g

e

e

r

r

 

 

8

8

4

4

1

1

 

 

S

S

i

i

l

l

v

v

e

e

r

r

 

 

S

S

h

h

i

i

e

e

l

l

d

d

 

 

P

P

o

o

w

w

e

e

r

r

 

 

M

M

a

a

n

n

a

a

g

g

e

e

r

r

 

 

S

S

 

 

(

(

W

W

i

i

t

t

h

h

 

 

b

b

u

u

i

i

l

l

t

t

-

-

i

i

n

n

 

 

p

p

o

o

w

w

e

e

r

r

 

 

s

s

u

u

p

p

p

p

l

l

y

y

 

 

u

u

n

n

i

i

t

t

)

)

 

 

 
 

 
 

 

 
 

 
 

 

 

 

Summary of Contents for Silver Shield Power Manager

Page 1: ...a ag ge er r S Si il lv ve er r S Sh hi ie el ld d P Po ow we er r M Ma an na ag ge er r 8 84 41 1 S Si il lv ve er r S Sh hi ie el ld d P Po ow we er r M Ma an na ag ge er r S S W Wi it th h b bu ui...

Page 2: ...3 Side panel with connectors of the SiS PM 841 4 Hardware requirements 5 Package contents 6 Installation of SiS PM S 7 Connection of other devices to the SiS PM S 8 Switching SiS PM S on and off conn...

Page 3: ...hardware based event time schedule The hardware schedule will work even with the managing computer switched off provided that the is connected to the optional power adapter The unit will keep performi...

Page 4: ...cker switch Indicator Socket 3 Silence button to suppress beeps Indicator POWER USB connector Non manageable socket Indicator Socket 4 Hardware schedule power supply connector 9VDC 0 5A For SIS PM onl...

Page 5: ...allow hardware schedule of SiS PM events to continue working with the managing computer switched off an extra power adapter 9VDC 0 5 is required optional SiS PMS contains the build in power adapter 5...

Page 6: ...for SiS PM only The sockets Socket 1 Socket 2 Socket 3 and Socket 4 can be managed or preprogrammed by computer via the USB interface SiS PM S can be used with other multi plugs and or surge protector...

Page 7: ...et has power to it SiS PM 841 sockets can be controlled by PC and by other external device which can support PM interface in particular CAS 441 PM CAS 841 PM Supervisory external device can read statu...

Page 8: ...t the program which will be launched when the power supply to the socket does not match the required event i e the socket must be on but there is no power supplied to it yet Check the When alarm goes...

Page 9: ...om the present time the loop period should also not exceed the difference between the time of the first entry and the present time plus 45 days 6 Loop period should not exceed 180 days 7 It is also po...

Page 10: ...to for files using the Browse button or typing it manually in the Title and Path name fields Specify the File name mask using wildcard characters After you have specified the folder and file name chec...

Page 11: ...following command line interface syntax is supported pm exe on off device name socket name Examples C Program Files Gembird Power Manager pm exe on sis pm socket1 E Utils PM3 pm exe off my sis pm tab...

Page 12: ...h the sign Indicator Socket x is on means there is power in this particular socket Main rocker switch is light up means SiS PM S is connected to the power supply and the SiS PM S is active 12 Technica...

Page 13: ...www gmb nl forum Disclaimer No effort have been spared to ensure that the information in this manual is correct and complete to the best of our knowledge However no liability is accepted for any erro...

Reviews: