background image

Safety Information

Adapter Plugs . . . . . . . . . . . . . . . . . . . .3

Connect Electricity  . . . . . . . . . . . . . . .2

Extension Cords  . . . . . . . . . . . . . . . . .3

Safety Precautions . . . . . . . . . . . . . . . .2

Operating Instructions

 . . . . . . . .4, 5

Care and Cleaning

Air Filter  . . . . . . . . . . . . . . . . . . . . . . . .6

Grille and Case . . . . . . . . . . . . . . . . . . .6

Outdoor Coils  . . . . . . . . . . . . . . . . . . .6

Installation Instructions

Through the Wall Installation—

Optional  . . . . . . . . . . . . . . . . . . . . . . .15

Window Installation . . . . . . . . . . .7–14

Troubleshooting Tips

 . . . . . . . . . .16

Normal Operating Sounds . . . . . . .16

Consumer Support

Consumer Support  . . . . .Back Cover

Product Registration  . . . . . . . . .17, 18

Warranty  . . . . . . . . . . . . . . . . . . . . . . .19

23-11-2130N-003

49-7411

01-01 JR 

AVE12

AVE15

AVE18
AVE22

Air Conditioners

Owner’s Manual &

Installation Instructions

www.GEAppliances.com

Write the model and serial numbers here:

Model # __________________________

Serial # __________________________

Find these numbers on a label on the 
side of the air conditioner and/or on a
label near the air discharge area.

Summary of Contents for AVE12

Page 1: ...ubleshooting Tips 16 Normal Operating Sounds 16 Consumer Support Consumer Support Back Cover Product Registration 17 18 Warranty 19 23 11 2130N 003 49 7411 01 01 JR AVE12 AVE15 AVE18 AVE22 Air Conditioners Owner s Manual Installation Instructions www GEAppliances com Write the model and serial numbers here Model __________________________ Serial __________________________ Find these numbers on a l...

Page 2: ... in the vicinity of this or any other appliance SAFETY PRECAUTIONS Do not under any circumstances cut or remove the third ground prong from the power cord For personal safety this appliance must be properly grounded The power cord of this appliance is equipped with a 3 prong grounding plug which mates with a standard 3 prong grounding wall outlet to minimize the possibility of electric shock hazar...

Page 3: ... made to a properly grounded 2 prong wall outlet by use of a UL listed adapter available at most local hardware stores The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord When disconnecting the power cord from the adapter always hold the adapter in place with one hand while pulling the power cord plug...

Page 4: ... number available on your knob For Quieter Nighttime Cooling Select LOW COOL with the temp control at midpoint Heating Descriptions For Normal Heating Select HIGH HEAT or LOW HEAT with the temp control at midpoint For Maximum Heating Select HIGH HEAT with the temp control at the lowest number available on your knob For Quieter Nighttime Heating Select LOW HEAT with the temp control at midpoint Tem...

Page 5: ... outside On some models the vent control is located above the control knobs On some models the vent control is located beside the air louvers Air Direction Two levers on each side of the grille let you control the air direction left or right Fingertip pressure on the tabs adjusts the air direction up or straight ahead Do not adjust the louvers down any lower than straight out Air that is blown dow...

Page 6: ...n the outdoor side of the air conditioner should be checked regularly If they are clogged with dirt or soot they may be professionally steam cleaned a service available through your GE service outlet Grille and Case Turn the air conditioner off and remove the plug from the wall outlet before cleaning To clean use water and a mild detergent Do not use bleach or abrasives Care and cleaning of the ai...

Page 7: ...ange the plug on the power cord of this air conditioner Aluminum house wiring may present special problems consult a qualified electrician Before You Begin Some models require 115 120 volt a c 60 Hz grounded outlet protected with a 15 amp time delay fuse or circuit breaker The 3 prong grounding plug minimizes the possibility of electric shock hazard If the wall outlet you plan to use is only a 2 p...

Page 8: ... Preparing to Install the Air Conditioner before beginning Parts Included Window Installation Instructions Case 2 filler panels 2 case side seals Window locking bracket 2 sliders 2 support brackets Foam top window gasket 3 8 hex head screws 6 3 8 slotted washer head screws 4 1 screws 4 Bolts 2 5 8 screws 3 Upholstery tacks 4 ...

Page 9: ...ils or screws provided by the installer 2 Read completely then follow step by step Window Requirements These instructions are for a standard double hung window You will need to modify them for other types of windows The air conditioner can be installed without the accordion panels if needed to fit in a narrow window See the window opening dimensions below All supporting parts must be secured to fi...

Page 10: ...und anti theft screws so they may be replaced at the end of the installation Slide the air conditioner from the case by grasping front flange of the evaporator cover and pulling forward while bracing the case NOTE The air conditioner is very heavy It may require two or more people to remove it from the case C B A 10 Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions I...

Page 11: ...ach side into the top retainer bar Carefully place the case in the window and align the center of the bottom tie bar with the centerline on the window stool Do not release your grip on the case until the window is in its final position Close the window until it touches behind the top retainer bar Do not close the window so tightly that the sliders cannot move Secure the case to the window stool us...

Page 12: ...t to each side of the case bottom using two 3 8 slotted washer head screws on each side The case should be slightly tilted to the outside Use a level about a 1 2 bubble will be the correct case slant to the outside 5 Measure and Cut the Window Filler Panels 6 Measure the distance X between the face of the window molding and the side of the case Measure both sides of the case separately Subtract 3 ...

Page 13: ...el out from the air conditioner case Make sure it contacts the window molding Slide the filler panel into place Use upholstery tacks to attach the filler panel to the face of the window molding through the holes provided Pull the sliders out until they contact the face of the window molding Note If a slider has slipped into the top retainer bar and cannot be pulled out use the slider on the other ...

Page 14: ...m between the glass and the window to prevent air and insects from getting into the room Slide the air conditioner into the case and replace the front grille Install the two ground anti theft screws removed at the beginning of the installation Make sure the unit is OFF before inserting cord plug into the outlet Check all seals and plug any remaining air gaps with a suitable weatherproof caulk D C ...

Page 15: ...tacle Place the case in the wall opening and secure with 12 1 long 10 wood screws NOTE Drill pilot holes if necessary for proper installation If the frame is oversized use shims to prevent case distortion C B A 1 The case may be installed through the wall in both existing and new construction Read completely then follow step by step Caulk all four sides on the outdoor side of the case to prevent m...

Page 16: ...icted Make sure there are no curtains blinds or furniture not cool as it should blocking the front of the air conditioner The temp control may Turn the knob to a higher number The highest setting not be set high enough provides maximum cooling The air filter is dirty Clean the filter at least every 30 days See the Operating Instructions section The room may have been hot When the air conditioner i...

Page 17: ...otection or you may request your money back on the remaining value of your contract No questions asked It s that simple Protect your refrigerator dishwasher washer and dryer range TV VCR and much more any brand Plus there s no extra charge for emergency service and low monthly financing is available Even icemaker coverage and food spoilage protection is offered You can rest easy knowing that all y...

Page 18: ...uct detach and return the form below to ensure that your product is registered or register online at www GEAppliances com 1 2 3 Model Number Serial Number Cut here Complete and mail your Consumer Product Ownership Registration today Have the peace of mind of knowing we can contact you in the unlikely event of a safety modification After mailing the registration below store this document in a safe ...

Page 19: ... to provide reasonable and necessary maintenance In commercial locations labor necessary to move the unit to a location where it is accessible for service by an individual technician Replacement of house fuses or resetting of circuit breakers Failure due to corrosion on models not corrosion protected Damage to the product caused by improper power supply voltage accident fire floods or acts of God ...

Page 20: ...at are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your warranty expires Parts and Accessories www GEAppliances com Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discover...

Reviews: