background image

GE

 

Security 

 

 REV 01.00 • ISS 02SEP09 

UVD-EVRDNR(-P) Camera User 

Manual 

Summary of Contents for UVD-EVRDNR

Page 1: ...GE Security REV 01 00 ISS 02SEP09 UVD EVRDNR P Camera User Manual ...

Page 2: ...r or visit us online at www gesecurity com FCC compliance This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency ...

Page 3: ...tion 7 Angle adjustment 7 Focus adjustment 8 Connect the monitor 8 Programming 8 Setup menu 8 Camera identification 9 Light control 10 Manual exposure menu 11 Day Night control 12 White balance 14 Picture control 14 Focus adjustment 15 Miscellaneous 15 External synchronization 16 Mirror 16 Mask 16 System Time 17 Back default 17 Menu Map 18 UVD EVRDNR P Camera User Manual i ...

Page 4: ......

Page 5: ...ectrical wiring and low voltage electrical connections Read these instructions and all ancillary documentation entirely before installing or operating this product Note A qualified service person complying with all applicable codes should perform all required hardware installation Safety terms These terms may appear in this manual CAUTION Cautions identify conditions or practices that may result i...

Page 6: ...life and high reliability OSD control allows eight masks to be shown on the screen for subjects requiring special protection due to privacy concerns Advanced OSD onscreen display control Signal to noise ratio better than 48 dB Isolated switching power 12 VDC or 24 VAC Vandal resistant housing User guidelines Use the following guidelines Program as many camera settings as possible before mounting t...

Page 7: ...s and hex key Use the video output BNC and power jack for normal system operation Use the monitor output cable for installation and maintenance Figure 1 Camera assembly Camera body Video monitor output System heater Power jack OSD control pad Video output BNC Figure 2 Monitor output cable 1 Monitor output BNC 2 Monitor output RCA UVD EVRDNR P Camera User Manual 5 ...

Page 8: ...the right to select or adjust the parameters of the selected item Down Moves the cursor downward to select an item Enter Press the center of the control pad to display the Setup menu If the selected item has its own menu press the control pad to enter a submenu Press the control pad for 2 seconds to save all settings and exit the Setup menu Installation Complete all the necessary programming befor...

Page 9: ... may be used for ground Camera installation To mount the camera attach the camera to the mounting surface using the appropriate fasteners Angle adjustment To adjust the horizontal angle of the platform up to 180 degrees turn the platform Figure 4 below To adjust the horizontal angle of the rotor up to 350 degrees turn the rotor on the platform Figure 4 below To adjust the vertical angle of the pla...

Page 10: ...rd video monitor to the system To connect the monitor do the following 1 Plug the monitor output cable Figure 2 on page 5 to the video monitor output connector Figure 1 on page 5 2 Connect the BNC cable to the video monitor 3 Press Enter see OSD control pad on page 9 to display the Setup menu Programming This chapter describes how to navigate the programming menus to adjust the camera settings Set...

Page 11: ...sor to Unlock and press Enter To unlock the Setup menu press Up Down and then press Enter in that order Camera identification To set the camera ID do the following 1 Move the cursor on the Setup menu Figure 6 above to Camera ID and press Enter to display the Camera ID submenu Figure 7 below Figure 7 Camera identification Character area Editing Command area Blinking 2 Move the cursor to the charact...

Page 12: ...era ID display 8 Press Up Down Right or Left to move the Camera ID to the desired position 9 Press Enter to fix the ID position and return to the previous menu Light control To adjust the light control do the following 1 Move the cursor on the Setup menu Figure 6 on page 9 to Light Cntl and press left or right to cycle between the DC Lens and ME Figure 9 below Figure 9 Light control menu selection...

Page 13: ...t or Right to adjust the Av Pk value on the DC iris lens after level setting Av value The electronic convergence is automatically adjusted for the average photometric method with the average video signal level of the object as the right photometric value Pk value The electronic convergence is automatically adjusted for the peak photometric method with the peak video signal level of the object as t...

Page 14: ...Return and press Enter to set the manual exposure and return to the previous menu Day Night control To adjust the white balance do the following 1 Move the cursor on the Setup menu Figure 6 on page 9 to D N CNTL 2 Press Left or Right to cycle between LUX DELAY SCHEDULE DAY and NIGHT Figure 13 below Figure 13 D N menu 3 To set Lux Delay press Enter when the Lux Delay option is displayed The Lux Del...

Page 15: ... 15 below 7 Move the cursor on the Schedule menu to the D N time position Press Left or Right to set hour from 0 23 and minute from 0 to 59 8 Move the cursor on the Schedule menu to the N D time position Press Left or Right to set hour from 0 23 and minute from 0 to 59 9 Move the cursor on the Schedule menu to the Choice D N type position to switch D N mode Figure 15 Schedule menu UVD EVRDNR P Cam...

Page 16: ...a adjusts the WB itself To adjust the white balance do the following 1 Move the cursor on the Setup menu Figure 6 on page 9 to White Bal 2 Press Left or Right to cycle between ATW AWB and PTL 3 To set PTL press Enter when displaying the PTL push to lock menu Figure 16 below Figure 16 Push to lock menu The camera will process white balance Observe that PTL push changes to PTL setting Wait until the...

Page 17: ... silhouetted Press Left or Right to select BLC on or BLC off 6 Move the cursor to the AGC automatic gain control position Increasing the AGC level increases camera sensitive at lower light levels Press Left or Right to increase or decrease the bright level low light condition Focus adjustment To adjust the focus do the following 1 Move the cursor on the Setup menu Figure 6 on page 9 to Focus adj 2...

Page 18: ...selected press Enter to display the Ext Sync menu 4 Press Left or Right to align the sync phase Mirror To adjust the mirror do the following 1 Move the cursor to the Mirror position 2 Press Left or Right to turn the setting on or off Mask To adjust the mask do the following 1 Move the cursor to the Mask position and press Enter to display the Mask menu Figure 19 below Figure 19 Mask submenu 16 UVD...

Page 19: ...hange the mask position and press Enter when the desired position is selected 6 Move the cursor to Size and press Enter Press the Up Down Left or Right to change the mask size and press Enter when the desired size is selected 7 Move the cursor to select Return and press Enter to set the mask and return to the previous menu System Time 1 SYSTEM HOUR Move the cursor to set hour from 0 to 23 2 SYSTEM...

Page 20: ...Menu Map ...

Reviews: