PHS925STSS 

GE Profile

™ 

Slide-In Induction Range

 

Specification Revised 11/11

220456

Listed by 

Underwriters 

Laboratories

Dimensions and Installation Information (in inches) 

Note:

 To reduce the possibility of scorching the side walls above the countertop 

when no load is present on burners, it is recommended that a minimum 6" 

spacing from adjacent side wall be allowed for possible extended high-heat 

element operation.

Receptacle Locations:

 For all 30" Slide-In Ranges locally approved flexible 

service cord or conduit must be used because terminals are not accessible 

after range installation. See shaded area in drawing for location of electrical 

outlet box. Recommended outlet locations allow range to be installed directly 

against rear wall. 

KW Rating

240V

12.2

208V

9.2

Breaker Size

240V

40 Amps

208V

40 Amps

Installation information:

 Before installing, consult installation instructions 

packed with product for current dimensional data. 

Note: 

Use a 4’ power cord to prevent interference with the storage drawer. Power cords 

4-1/2’ to 6’ long may have to be dressed to allow for proper drawer closing.

Minimum dimensions between cooktop, walls and above the cooktop: 

A. Make sure the wall covering, countertop, flooring and cabinets around the range can 

withstand the heat (up to 200°F) generated by the range. 
B. Allow 30" minimum clearance between surface units and bottom of unprotected wood or 

metal cabinet, or allow a 24" minimum when bottom of wood or metal cabinet is protected by 

no less than 1/4" thick flame retardant millboard covered with not less than No 28 MSG sheet 

metal, (.015"), .015" thick stainless steel, .024" aluminum or .020" copper. Acceptable electrical 

outlet area. Orient electrical receptacle so the length is parallel to floor.
C. This appliance has been approved for 0" spacing to adjacent surfaces above the cooktop. 

However, a 6" minimum spacing to surfaces less than 15" above the cooktop and adjacent 

cabinet is recommended to reduce exposure to steam, grease splatter and heat. To reduce 

the risk of burns or fire when reaching over hot surface elements, cabinet storage space 

above the cooktop should be avoided. If cabinet storage space is to be provided above the 

cooktop, the risk can be reduced by installing a range hood that projects at least 5" beyond 

the front of the cabinets. Cabinets installed above the cooktop must be no deeper than 13".

Note:

 Use a 4'power cord to prevent 

interference with unit when installing. 

All GE ranges are equipped with 

an Anti-Tip device. The installation 

of this device is an important, 

required step in the installation  

of the range.