background image

Specification Revised 10/15

GFDN110ED 

GE

®

 Series 7.0 Cu. Ft. Super Capacity Front Load Electric Dryer 

For answers to your Monogram, GE Profile

™ 

Series  

or GE

®

 Series appliance questions, visit our website  

at geappliances.com or call GE Answer Center

®

 

service, 800.626.2000.

Listed by 

Underwriters 

Laboratories

Dimensions anD installation information (in inches) 

exhaust options: 

4-way via rear, right, left and bottom.

circuit requirements: 

An individual, properly grounded 

branch circuit, protected by a 30-amp circuit breaker or a time-

delay fuse, is required.

note: 

Dryer wall outlet must be located within 36" of service 

cord entry and accessible when dryer is mounted in position.

installation information: 

For complete information, 

see installation instructions packed with your dryer.

2-1/2

1-3/4

12

3-1/2

Electrical 

Connection

Gas Pipe 

Connection

27

32-3/16

39-3/8

4-1/2

4-3/8

electric Dryer rating

120V/240V

5600W, 24A, 60Hz

120V/208V

4400W, 22A, 60Hz

Summary of Contents for GFDN110ED

Page 1: ...s 4 way via rear right left and bottom Circuit Requirements An individual properly grounded branch circuit protected by a 30 amp circuit breaker or a time delay fuse is required Note Dryer wall outlet must be located within 36 of service cord entry and accessible when dryer is mounted in position Installation Information For complete information see installation instructions packed with your dryer...

Page 2: ...se ventilated and must contain a minimum of 60 sq in of open area equally distributed If this closet contains both a washer and a dryer doors must contain a minimum of 120 sq in of open area equally distributed No other fuel burning appliance shall be installed in the same closet with a gas dryer Bathroom or Bedroom Installation The dryer MUST be exhausted to the outdoors The installation must con...

Page 3: ...nclosed house floor crawl space or into an attic since the accumulated lint could create a fire hazard or moisture could cause damage Never terminate the exhaust into a common duct or plenum with a kitchen exhaust since the combination of lint and grease could create a fire hazard Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts bird nesting etc The wall cap must al...

Page 4: ...s continually monitor temperature with a sensor bar that measures moisture to prevent over drying Speed Dry quickly dries items and small loads for families on the go eDry option energy saving option reduces dry temperatures on select cycles without sacrificing performance 4 heat settings provide the right temperature for the right drying needs 6 dry cycles additional cycles for your clothes dryin...

Reviews: