Modular Fixtures - Small & Medium (EASM & EAMM)
Evolve
™
LED Area Light
•
This luminaire is designed for outdoor lighting service,
and should not be used in areas of limited ventilation,
or in high ambient temperatures.
•
Best results will be obtained if installed and maintained
according to the following recommendations.
•
Luminaire is designed to operate in ambient
temperatures ranging from -40°C to 50°C and to be
mounted horizontally to a vertical pole with LEDs
facing down, as shown.
GE
Lighting
Installation Guide
GEH-6006A
imagination at work
SPECIFICATIONS
•
Weight: Maximum weight <50 lbs (22.68 kg)
•
EPA: 1.35 sq ft max (0.13 sq M) (Calculated using
1.30 Cd X Total Area of 1.04 ft
2
)
•
IP Rating: Optical 65, Standard Electrical Enclosure:
UL 1598 Wet Location Rated
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This Class [A] RFLD complies with the Canadian standard ICES-003.
Ce DEFR de la classe [ A ] est conforme à la NMB-003 du Canada.
Note: This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area
is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
Save these instructions for future use.
WARNING
Risk of electrical shock.
Disconnect power before servicing
or installing product.
CAUTION
Risk of injury.
Wear safety glasses and gloves during
installation and servicing.
WARNING
Risk of injury or damage.
Unit will fall if not installed
properly. Follow installation instructions.