BEFORE YOU BEGIN

Read these instructions completely and carefully.

Tetra

®

 

Slim EdgeStrip

LED Lighting System

(GE12BI71-S1, GE12BI50-S1, GE12BI41-S1, GE12BI32-S2)

Installation Guide

12

Volt

Prepare Electrical Wiring

Electrical Requirements

•  Limited to use in dry and damp locations. The suitability of  

 

 

  rain enclosures shall be determined if intended for wet location.

•  The grounding and bonding of the LED Driver shall    

 

    be done in accordance with National Electric Code (NEC)  
    Article 600.

•  Follow all National Electric Codes (NEC) and local codes.

• These products are only suitable for connection to a circuit  

 

 

  from a Class 2 power source. These products have not been    

 

  evaluated for use when connected to a power source that does  

 

  not comply with Class 2 voltage and energy limited supplies.

Save These Instructions

Use only in the manner intended by the manufacturer.

If you have any questions, contact the manufacturer.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and 

(2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are 

designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, 

uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio 

communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the 

interference at his own expense.
This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005 du Canada.

EN

Instruction Guide

AR

BG

Инструкции за монтаж

CS

Montážní příručka

DA

Monteringsvejledning

DE

Einbauanleitung

EL

ΟδηγόςΕγκατάστασης

ES

Guía de instalación

ET

Paigaldusjuhend

FI

Asennusohje

FR

Guide d’installation

HR

Priručnik za instalaciju

HU

Felszerelési útmutató

IT

Guida all’installazione

LT

Sumontavimo vadovas

LV

Uzstādīšanas instrukcija

NL

Installatiehandleiding

NO

Monteringsanvisning

PL

Instrukcja instalacji

PT

Guia de Instalação

RO

Ghid de instalare

RU

Инструкции по установке

SV

Installationsanvisning

SL

Navodila za namestitev

SK

Návod na inštaláciu

TR

Montaj Kılavuzu

UK

Посібник з установлення

ZH

安装指南

بيكرتلا ليلد

RETROFIT SIGN CONVERSION LED KIT FOR USE ONLY IN 

ACCORDANCE WITH KIT INSTRUCTIONS.
KIT IS COMPLETE ONLY WHEN ALL PARTS REQUIRED BY 

THE INSTRUCTIONS ARE PRESENT.
TROUSSE DE CONVERSION À DEL POUR LA 

MODERNISATION DES ENSEIGNES
À UTILISER CONFORMÉMENT AU GUIDE D’INSTALLATION.

WARNING/AVERTISSEMENT

RISK OF ELECTRIC SHOCK

 

Turn power off before inspection, installation or 

removal.

 

Properly ground GE power supply enclosure.

RISK OF FIRE

 

Use only UL approved wire for input/output 

connections. Minimum size 18 AWG (0.82mm

2

)

 

Follow all NEC and local codes.

 

Not to be submerged or used in a marine environment.

RISK OF FIRE OR ELECTRIC SHOCK

 

LED Retrofit Kit installation requires knowledge of sign 

electrical systems. If not qualified, do not attempt 

installation. Contact a qualified electrician.

 

Install this kit only in host signs that have been identified 

in the installation instructions and where the input rating 

of the retrofit kit does not exceed the input rating of the 

sign.

 

Installation of this LED retrofit kit may involve drilling or 

punching of holes into the structure of the sign. Check 

for enclosed wiring and components to avoid damage 

to wiring and electrical parts.

 

Do not make or alter any open holes in an enclosure of 

wiring or electrical components during kit installation.

RISQUES DE DÉCHARGES ÉLECTRIQUES

 

Coupez l’alimentation avant l’inspection, l’installation ou le déplacement.

 

Assurez-vous de correctement mettre à terre l’alimentation électrique GE.

RISQUES D’INCENDIE

 

N’utilisez que des fils approuvés par UL pour les entrées/sorties de connexion. 

Taille minimum 18 AWG (0.82mm

2

)

 

Respectez tous les codes NEC et codes locaux.

 

Ne pas submerger ou installer dans un environnement marin.

RISQUE D’INCENDIE OU DE CHOC ÉLECTRIQUE 

 

L’installation de l’équipement de remplacement DEL exige Ia connaissance des 

systèmes électriques pour enseignes. Si non qualifié, ne tentez pas d’installation. 

Veuillez contacter un électricien qualifié.

 

Risque d’incendie ou de choc Électrique. Installez cet ensemble seulement dans 

des enseignes hôtes qui ont été identifiés dans les instructions d’installation et 

dont la capacité d’entrée de l’ensemble ne dépasse pas la capacité d’entrée de 

l’enseigne.

 

L’installation de cet équipement de remplacement DEL peut impliquer le perçage 

ou le poinçonnage de trous dans la structure du panneau Vérifiez le câblage et 

les composants inclus pour éviter d’endommager le câblage et les composants 

électriques.

 

Ne pas faire ou modifier les trous ouverts dans une enceinte de câblage 

ou de composants électriques pendant l’installation de cet équipement de 

remplacement DEL.

1

Summary of Contents for Current Tetra Slim EdgeStrip Series

Page 1: ...tev SK Návod na inštaláciu TR Montaj Kılavuzu UK Посібник з установлення ZH 安装指南 التركيب دليل RETROFIT SIGN CONVERSION LED KIT FOR USE ONLY IN ACCORDANCE WITH KIT INSTRUCTIONS KIT IS COMPLETE ONLY WHEN ALL PARTS REQUIRED BY THE INSTRUCTIONS ARE PRESENT TROUSSE DE CONVERSION À DEL POUR LA MODERNISATION DES ENSEIGNES À UTILISER CONFORMÉMENT AU GUIDE D INSTALLATION WARNING AVERTISSEMENT RISK OF ELECT...

Page 2: ...8 M4 screws 1 8 inch 3 2 mm rivets or silicone Components and Tools Required 5 1 2 3 4 UL approved 18 AWG 0 82 mm2 supply wire UL approved 22 14 AWG 0 33 2 08 mm2 wire connectors or 22 18 AWG 0 33 0 82 mm2 in line IDC connectors 6 or 8 M3 or M4 screws 1 8 inch 3 2 mm rivets or electrical grade silicone 3 2 1 4 Tetra 12 Volt Power Supply Tetra Slim EdgeStrip LED modules Electrical grade RTV silicon...

Page 3: ... 52 m 6 ft 1 83 m 7 ft 2 13 m Width 1 ft 0 30 m 3 8 2 mods on one side 3 8 3 mods on one side 3 8 5 mods on one side 3 8 6 mods on one side 3 8 8 mods on one side 3 8 9 mods on one side 3 8 11 mods on one side 2 ft 0 62 m 3 8 3 mods on one side 3 8 3 mods on one side 3 8 5 mods on one side 3 8 6 mods on one side 3 8 8 mods on one side 3 8 9 mods on one side 3 8 11 mods on one side 3 ft 0 91 m 3 8 ...

Page 4: ...electrical codes whichever is less 2 Existing Signs Only Remove the existing lighting equipment to be replaced such as neon tubing or fluorescent tubes and associated transformers and ballasts Care should be taken not to break the existing neon or fluorescent tubes NOTE Follow all federal and local regulations when disposing of neon tubing fluorescent tubes transformers and ballasts 3 Existing Sig...

Reviews: