Summary of Contents for Ambiente 24 S

Page 1: ...e brume NL Gebruiksaanwijzing Vijververnevelaar set S Bruksanvisning Dimspridar set I Istruzioni per l uso Set diffusore di nebbia E Manual de instrucciones Kit difusor de bruma P Instruções de utilização Conjunto nebulizador DK Brugsanvisning Tågespreder D GB F NL S I E P DK Ambiente 24 S Ambiente 48 S Art 7976 Art 7977 ...

Page 2: ...t Generator Set their proper use and the notes on safety For safety reasons children under the age of 16 as well as people who are not familiar with these operating instructions must not use this GARDENA Mist Generator Set v Please keep these operating instructions in a safe place 1 Where to use Your GARDENA Mist Generator Set 11 2 Safety instructions 11 3 Initial Operation 12 4 Operation 14 5 Put...

Page 3: ...ominal fault current 30 mA DIN VDE 0100 702 v If in doubt please consult a qualified electrician The transformer is approved for outdoor use Do not expose the transformer to direct rain or mechanical damage Information on remote control Use of the remote control may cause malfunctions in the operation of electronic prostheses pacemakers hearing aids insulin pumps etc v Consult your doctor about th...

Page 4: ... water feature nozzle 3 Connect Mist Generator to transformer see below 4 Adjust the water feature so that the water exiting does not directly strike the mist membranes impairment of Mist Generator effect 1 Set up transformer at a dry location protected from flooding The transformer can be screwed to a firm base using the holes 5 4 mm 2 Fit the connecting cable of the Mist Generator to the trans f...

Page 5: ...e On Off button switches the Mist Generator on and off Sensor button The Mist Generator is equipped with a dusk sensor that switches the LEDs on automatically when it is getting dark Activate dusk sensor v Press Sensor button Green LEDs flash for 3 seconds Sensor is activated Buttons and only function when it is getting dark Deactivate dusk sensor v Press Sensor button Red LEDs flash for 3 seconds...

Page 6: ...sposed of in line with local environmental regulations Only dispose of batteries when they are flat v Return flat batteries to the place you bought them or dispose of them properly at your local recycling disposal centre 6 Maintenance DANGER Electric shock V Before cleaning remove power plug of transformer When the mist effect becomes reduced the Mist Generator needs to be cleaned No caustic abras...

Page 7: ...nit B in again up to the stop under the catch lugs in cover C 9 Reposition the cover C and screw the 3 screws z S back in WARNING A If the membrane unit is not pressed right into the cover of the mist generator C it will be irreparably damaged in operation If a membrane LED unit no longer functions the entire unit can be replaced Only original GARDENA membrane LED units should be used Replacement ...

Page 8: ...r plug functioning Defective cable connection v Remove power plug and check all outgoing connections and cables Water level too low v Ensure water level is sufficient Use of distilled water v Do not use distilled water only for Ambiente 48 S Fuse of transformer defective v Replace fuse Individual membrane Membrane unit not fully v Fully insert membrane membrane unit not inserted in generator unit ...

Page 9: ...defects of the unit that can be proved to be material or manufacturing faults Under warranty we will either replace the unit or repair it free of charge if the following conditions apply The unit must have been handled properly and in keeping with the requirements of the operating instructions Neither the purchaser or a non authorised third party have attempted to repair the unit As wear parts the...

Page 10: ...ten om skadan beror på att produkten har reparerats felaktigt eller om vid repa ration eller utbyte andra än Original GARDENA reservdelar har använts Samma sak gäller för kompletteringsdelar och tillbehör I Responsabilità Si rende espressamente noto che conformemente alla legislazione sulla del prodotto responsabilità del prodotto non si risponde di danni causati da nostri arti coli se originati d...

Page 11: ...ssigné GARDENA Manufacturing GmbH Hans Lorenser Str 40 D 89079 Ulm déclare qu à la sortie de ses usines le matériel neuf désigné ci dessous était conforme aux prescriptions des directives européennes énoncées ci après et conforme aux règles de sécurité et autres règles qui lui sont applicables dans le cadre de l Union européenne Toute modification portée sur ce produit sans l accord express de GAR...

Page 12: ...oj ojk is Ireland Michael McLoughlin Sons Hardware Limited Long Mile Road Dublin 12 Italy GARDENA Italia S p A Via Donizetti 22 20020 Lainate Mi Phone 39 02 93 94 79 1 info gardenaitalia it Japan KAKUICHI Co Ltd Sumitomo Realty Development Kojimachi BLDG 8F 5 1 Nibanncyo Chiyoda ku Tokyo 102 0084 Phone 81 33 264 4721 m_ishihara kaku ichi co jp Luxembourg Magasins Jules Neuberg Grand Rue 30 Boîte p...