Confidentiality Notice .....................................................................................................................1

 

Product Overview ............................................................................................................................1

 

Models ...................................................................................................................................................... 2

 

System Requirements and Limitations ................................................................................................. 2

 

Tips for VoIP Subscribers ...................................................................................................................... 2

 

Features and Functions .......................................................................................................................... 3

 

Operation  ........................................................................................................................................3

 

Placing an Autodial Call ......................................................................................................................... 3

 

Placing a General Telephone Call ......................................................................................................... 3

 

Receiving a Call ....................................................................................................................................... 3

 

Multicast Broadcasting ........................................................................................................................... 4

 

Monitoring and Reporting ..................................................................................................................... 4

 

Installation ......................................................................................................................................4

 

General Information ............................................................................................................................... 4

 

Safety Guidelines ..................................................................................................................................... 5

 

Station Placement .................................................................................................................................... 5

 

Model 295-702F ....................................................................................................................................... 5

 

Model 295-702W ..................................................................................................................................... 8

 

Field Wiring ............................................................................................................................................. 9

 

Power .................................................................................................................................................. 10 
Network............................................................................................................................................... 10 
I/O ....................................................................................................................................................... 10 
Recommended Cabling ....................................................................................................................... 11 

Status Indication ................................................................................................................................... 11

 

Power .................................................................................................................................................. 11 
Heartbeat ............................................................................................................................................. 11 
EACT .................................................................................................................................................. 11 

Programming ................................................................................................................................11

 

VoIP PCBA Setup ................................................................................................................................. 12

 

VoIP PCBA Initial Network Configuration ....................................................................................... 12

 

VoIP Telephone Input Contacts .......................................................................................................... 12

 

VoIP Telephone Output Contacts ....................................................................................................... 12

 

Summary of Contents for Clean Phone 295-702F

Page 1: ...Tips for VoIP Subscribers 2 Features and Functions 3 Operation 3 Placing an Autodial Call 3 Placing a General Telephone Call 3 Receiving a Call 3 Multicast Broadcasting 4 Monitoring and Reporting 4 In...

Page 2: ...TRONICS COM FOR PRODUCT LITERATURE AND MANUALS Maintenance 13 General Information 13 Service 13 Troubleshooting 13 Replacement Parts and Accessories 14 Specifications 14 Power 14 Networking 14 Inputs...

Page 3: ...hole or in part directly or indirectly to any third party Product Overview The GAI Tronics Model 295 702F Flush Mount and Model 295 702W Wall Mount Clean Phone VoIP Voice over Internet Protocol Teleph...

Page 4: ...lephones Conferences are limited by the customer s LAN media capabilities and the services available at each telephone Each telephone can also receive multicast broadcasts Multicast allows a single au...

Page 5: ...to place an immediate call to a preprogrammed number The hookswitch indicator illuminates when the call is connected The call is terminated by pressing the ON OFF push button the receiving caller han...

Page 6: ...can be signaled to a remote site using three methods syslog output over TCP SMTP mail message TMA Telephone Management Application software purchased separately Available alarms handset integrity loo...

Page 7: ...away from other telephones located nearby reduce the volume level Avoid feedback problems by installing each Clean Phone VoIP telephone in a separate room and wall Model 295 702F The mounting and wiri...

Page 8: ...eral wipe down cleaning and to prevent collection internally and externally of particulate matter Additional protection against moisture can be attained by sealing between the outer edge of the teleph...

Page 9: ...470G Clean Phone VoIP Telephones Page 7 of 15 P Standard IOMs Current Release 42004 Instr Manuals 42004 470G docx 05 19 Figure 6 Wall Cut out Dimensions for Model 295 702F Figure 7 Back Box for Model...

Page 10: ...box see Figure 4 and Figure 8 4 Position the back box so that it is level on the wall in the desired location 5 Use the back box as a template to drill the lower right and upper left corners holes an...

Page 11: ...elow see Figure 9 for wiring details and Table 5 for the recommended conductor sizes NOTE Consult the National Electrical Code NFPA 70 Canadian Standards Association CSA 22 1 and local codes for the s...

Page 12: ...rminal of P5 see Figure 9 Table 2 Power P5 Pin Label Description 1 Positive 2 Negative Ground The enclosure must be connected to earth ground Install a 6 ring lug on the ground conductor and secure it...

Page 13: ...ts Two conductor No 22 AWG is typical Output contacts Two conductor No 18 AWG is typical Status Indication Power The Power LED located on the VoIP PCBA illuminates when power is applied to the telepho...

Page 14: ...tions of these VoIP telephones VoIP Telephone Input Contacts Each Clean Phone VoIP telephone accepts four volt free inputs see the Specifications section for the input contact ratings The function of...

Page 15: ...technicians in their troubleshooting efforts Call 800 492 1212 inside the USA or 610 777 1374 outside the USA for help in identifying the closest regional service center Troubleshooting Table 6 Troubl...

Page 16: ...static IP provisioning or DHCP STUN client NAT traversal Call control signaling SIP RFC3261 compliant loose routing Configuration embedded web server configuration file download direct serial connect...

Page 17: ...ion Sulfuric acid 10 Caustic soda 40 Linseed Oil Tomato Ketchup Cutting oil Methanol Trichloroacetic acid 50 Cylohexanol Nitric Acid 10 White spirit Diacetone alcohol Paraffin oil Windex1 Diesel Persi...

Page 18: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Reviews: