background image

Pub. 42004-484F 

GAI-Tronics Corporation  400 E. Wyomissing Ave.  Mohnton, PA  19540  USA 

610-777-1374  

  800-492-1212  

  Fax:  610-796-5954 

V

ISIT WWW

.

GAI

-

TRONICS

.

COM FOR PRODUCT LITERATURE AND MANUALS

 

ATTENTION! 

Replacing an existing Model 295F or 
295W with this telephone (Model 295-
001F or 295-001W) requires removing 
the existing 48 V dc power supply 
and replacing it with the 5 V dc power 
supply included with this telephone 
(or other 5 V dc source). 

Connecting 48 V dc to this telephone 
will cause severe damage. 

 

 

Summary of Contents for 295-001F

Page 1: ...OM FOR PRODUCT LITERATURE AND MANUALS ATTENTION Replacing an existing Model 295F or 295W with this telephone Model 295 001F or 295 001W requires removing the existing 48 V dc power supply and replacin...

Page 2: ...TMA 6 Operation 7 Placing an Autodial Call from an Analog Clean Phone 7 Placing a General Telephone Call 7 Receiving a Call 7 Installation 8 General Information 8 Safety Guidelines 8 General Installat...

Page 3: ...LS Local 21 Programming Sequence 22 Password Disabled Programming 22 Programming Sequences 23 Dialing Options 23 Password Protection 25 Auto Answer Alert Feature 25 Off Hook Ringing 26 Disconnect Opti...

Page 4: ...nformation contained herein and such information may only be used in connection with the operation of your GAI Tronics product or system This manual may not be disclosed in any form in whole or in par...

Page 5: ...option which sets the amount of time lapse between the auto dial button press and the actual dialing operation The default time period of 10 seconds could be too long if the feature is to be used for...

Page 6: ...The basic TMA package Model 12509 042 includes a single line transceiver for polling a single telephone at a time With each telephone requiring approximately 90 seconds to relay its health status to T...

Page 7: ...up or the defined timeout of the call duration Placing a General Telephone Call To place a general telephone call 1 Press the ON OFF push button 2 Wait for the dial tone 3 Use the keypad to dial the d...

Page 8: ...to ensure the safety of all personnel Do not install telephone wiring during a lightning storm Electrostatic Discharge ESD Protection Your telephone may have an earth ground terminal provision If so...

Page 9: ...telephone operation difficulties with programming or premature disconnection of calls Special system features voice mail call waiting etc could also create problems if not disabled Successful shared...

Page 10: ...t and upper left corners and secure the bracket with screws Drill the rest of the holes you intend to use and secure the bracket with the remaining screws 7 Connect the field telephone line to the RJ1...

Page 11: ...PUB 42004 484F ANALOG CLEAN PHONE TELEPHONES PAGE 11 of 33 p standard ioms current release 42004 instr manuals 42004 484f docx 09 15 Figure 4 Inside Front Panel...

Page 12: ...PUB 42004 484F ANALOG CLEAN PHONE TELEPHONES PAGE 12 of 33 p standard ioms current release 42004 instr manuals 42004 484f docx 09 15 Figure 5 Wall Cut out Dimensions for Model 295 001F...

Page 13: ...PUB 42004 484F ANALOG CLEAN PHONE TELEPHONES PAGE 13 of 33 p standard ioms current release 42004 instr manuals 42004 484f docx 09 15 Figure 6 Back Box for Model 295 001F Figure 7 Front Panel...

Page 14: ...ches from the end of the cable Snap the bushing closed and insert into the D hole in the back of the back box See Figure 3 and Figure 8 5 Secure the back box to the mounting surface 6 Connect the fiel...

Page 15: ...PUB 42004 484F ANALOG CLEAN PHONE TELEPHONES PAGE 15 of 33 p standard ioms current release 42004 instr manuals 42004 484f docx 09 15 Figure 8 Mounting the Model 295 001W...

Page 16: ...he desired distance to the telephone The distance between the telephone and the 5 V dc power source is limited only by the maximum allowable wire resistance 32 ohms See Table 2 for calculated distance...

Page 17: ...r in position EN Disable J14 jumper in position DIS Do not use this setting except under the direction of GAI Tronics personnel NOTE The Auto answer feature must be enabled to allow the GAI Tronics Te...

Page 18: ...position STD Low PowerModeConfiguration Factory Setting Low Power Mode Disabled For some installations in which only minimal loop current is available the performance of the telephone may be improved...

Page 19: ...cts to TB2 on the telephone s PCBA refer to Figure 9 This output closes when the AUTO DIAL1 push button is pressed and remains in that state for the duration of the telephone call NOTE Output 1 can be...

Page 20: ...PUB 42004 484F ANALOG CLEAN PHONE TELEPHONES PAGE 20 of 33 p standard ioms current release 42004 instr manuals 42004 484f docx 09 15 Figure 9 No 69577 101 PCBA Top View...

Page 21: ...sed Normal telephone operation is identical in either mode of operation Each Clean Phone telephone is factory programmed to receive Standard Mode commands Factory default settings are shown in Table 1...

Page 22: ...digit entries or if an invalid password is entered 2 If DTMF digits have not been dialed within 3 seconds of the first success tone the telephone will exit programming mode and revert to a standard vo...

Page 23: ...ll numbers have been attempted one attempt each When operating in SMART mode the number of attempts to call each programmed number can be increased as required two attempts each three attempts each et...

Page 24: ...e as AUTO DIAL1 Number 1 except the sequence ends in 2 instead of 1 None AUTO DIAL1 Number 3 DD 3 Same as AUTO DIAL1 Number 1 except the sequence ends in 3 instead of 1 None AUTO DIAL2 DD 4 DD 5 DD 6...

Page 25: ...ogramming Feature Key Sequence Description Default Password Protection 1 4 N N N N A four digit password must be supplied to remotely program the telephone If you change the password and cannot enter...

Page 26: ...Ringing Feature Key Sequence Description Default Off Hook Ringing 2 2 L Enabling the Off Hook Ringing feature allows a person to call the telephone and have the telephone function as a normal telephon...

Page 27: ...ial Tone Disconnect Option 1 9 L NOTE Use this option only if no other disconnect options are available If this option is enabled the telephone automatically terminates a call if it detects a dial ton...

Page 28: ...put 4 can be set in the range of 0 1 to 12 7 seconds in 0 1 second increments Table 10 Output 4 Control Options Feature Key Sequence Description Default Control Sequence N N 8 Assigns the digits NN as...

Page 29: ...pically within less than 1 second after the unit completes the dialing sequence Use of the Early Microphone feature includes an operational risk that ring back tones can be missed or audio received by...

Page 30: ...nds Ring down Operation 1 None Password Protection Feature Programming see Table 5 on page 25 Password Protection 14NNNN 2468 Disconnect Options Programming see Table 8 on page 27 Call Time out Discon...

Page 31: ...om the TMA PC Maintenance WARNING This product can contain hazardous voltages Always remove power to this station prior to servicing General Information 1 Inspect and replace frayed or cracked wiring...

Page 32: ...assembly Conformal coated Chemical Resistance Clean Phone graphic overlay is designed to withstand exposure to many chemicals Please contact the factory for questions pertaining to chemicals not list...

Page 33: ...panel 12 00 W 12 00 H inches 304 8 304 8 mm Back enclosure 12 00 W 12 00 H 2 06 D inches 304 8 304 8 52 3 mm Shipping weight dimensions 12 15 lbs 17 00 17 00 11 00 inches Approval Standards Safety of...

Page 34: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Reviews: