A Word to the Owner of the DFF3-UHD

Congratulations on your choice of the FURUNO DFF3-UHD Network Fish Finder. The DFF3-UHD is a net-
work fish finder designed for use with the NavNet TZtouch3 (TZT9F/12F/16F/19F, Ver. 3.01 or higher) and 
NavNet TZtouch2 (TZT2BB only, Ver.9.01 or higher). Please carefully read and follow the recommended 
procedures for installation and maintenance. Thank you for considering and purchasing FURUNO.

Operational Cautions

• A separate power supply is required. Take the power from the ship's mains via the ship's switchboard.
• The DFF3-UHD is not turned off when the multi function display is powered off. The DFF3-UHD's standby 

power is 6.2 W, so turn it off from the ship’s switchboard when it is not in use.

• DFF3-UHD does not support the Bottom Discrimination, RezBoost, or ACCU-FISH.
• Do not transmit with the transducer out of water, to prevent damage to the transducer.
• Use the multi function display to change the program version of the power amp. Contact FURUNO for 

information on how to upgrade program version.

• When using two types of transducers, set them from [Fishfinder]-[Transducer Setup]-[Transducer Setup]-

[Type] of the NavNet TZtouch3 and NavNet TZtouch2. Because the equipment has only one TDID port, 

two TDIDs cannot be read.

• The following concern acts as our importer in Europe, as defined in DECISION No 768/2008/EC.

- Name: FURUNO EUROPE B.V.

- Address: Ridderhaven 19B, 2984 BT Ridderkerk, The Netherlands

• The following concern acts as our importer in UK, as defined in SI 2016/1025 as amended SI 2019/470.

- Name: FURUNO (UK) LTD.

- Address: West Building Penner Road Havant Hampshire PO9 1QY, U.K.

Safety Instructions

The installer must read the safety instructions before attempting to install the equipment.

CAUTION

Observe the following compass safe 
distance to prevent interference to a 
magnetic compass:

Standard compass Steering compass

0.35 m

0.3 m

Do not disassemble or modify the 
equipment.

Fire, electrical shock or serious injury 
can result.

Use the proper fuse.

Use of a wrong fuse can damage the 
equipment and may cause fire.

WARNING

WARNING

Warning, Caution

Indicates a potentially hazardous situation which, if not avoided, 
could result in death or serious injury.

Indicates a potentially hazardous situation which, if not avoided, 
could result in minor or moderate injury.

CAUTION

Prohibitive Action

Mandatory Action

12VDC

24VDC

7.5 A

7.5 A

Summary of Contents for DFF3-UHD

Page 1: ... information on how to upgrade program version When using two types of transducers set them from Fishfinder Transducer Setup Transducer Setup Type of the NavNet TZtouch3 and NavNet TZtouch2 Because the equipment has only one TDID port two TDIDs cannot be read The following concern acts as our importer in Europe as defined in DECISION No 768 2008 EC Name FURUNO EUROPE B V Address Ridderhaven 19B 29...

Page 2: ...e around the unit Name Type Code No Qty Remark Network Fish Finder DFF3 UHD 1 Installation Materials CP02 09900 000 038 530 1 FRU 3P FF A002M 001 Cable assembly 001 197 092 10 MOD Z071 050 LAN ca ble 001 167 890 10 CP02 09901 EMI core and Self tapping screw 001 621 550 Name Type Code No Qty Remark Extension Cable C44 02 30M 000 190 455 1 For tank w transducer CM265LH CM265LM CM599LH CM599LM PM111L...

Page 3: ... 4 Tightly fasten the other two screws to fix the unit in place NOTE For mounting on a bulkhead the connectors must face downward Wiring Wiring Outline The figure below shows the inserting position of each cables for the DFF3 UHD Refer to the interconnection diagram for details Inserting position of cables Tabletop mount Bulkhead mount OK NO POWER EXT KP NETWORK Transducer Grounding terminal Trans...

Page 4: ...hen tighten the super gland 7 Remove the WAGO connectors from the PCB then attach the transducer cable to the connector 8 Clamp the braided shield with a cable clamp 6 6 150 150 150 150 30 30 30 30 Braided shield Braided shield Drain w CHIRP transducer cable Single frequency transducer cable Co Sheath Wrap the shield onto the sheath Vinyl tape 10 mm Clamp here on step 10 Vinyl tape 10 mm Clamp her...

Page 5: ... the WAGO connector from the PCB and connect it to the external KP signal cable 16 Connect WAGO connector to the PCB 17 Tighten the seal nut to fasten the cable 18 Attach the EMI core GRFC 8 supplied to the power cable near the super gland to prevent noise see figure below 19 Attach the ground wire IV 1 25sq local supply to the ground terminal with a crimp on lug M3 local supply to prevent interfe...

Page 6: ...y Communication error with NavNet device or internal fan error see Troubleshooting about how to solve the prob lem Problem Reason Cannot turn on power The power cable is disconnected or damaged Check the power cable and if it damaged replace it Check the ship s mains and check if the switchboard is turned on Check the fuse on the power cable If the fuse has blown find the cause then replace it No ...

Page 7: ...hers Please refer to the following for details on the terms of the software Intel socfpga hwlib Copyright 2013 2020 Intel Corporation All Rights Reserved Redistribution and use in source and binary forms with or without modification are permitted provided that the following conditions are met 1 Redistributions of source code must retain the above copyright notice this list of conditions and the fo...

Page 8: ...N HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY WHETHER IN CONTRACT STRICT LIABILITY OR TORT INCLUDING NEGLIGENCE OR OTHERWISE ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Altera SoCFPGA HardwareLib MPL Altera MPL preloader configured for use with SDMMC Connectal The initial commit is the unmodified sourcecode from Altera The original source ...

Page 9: ... 工事材料 INSTALLATION MATERIALS ケーブル 組品 CABLE ASSEMBLY FRU 3P FF A002M 001 000 197 092 10 1 ケーブル 組品 LAN LAN CABLE ASSEMBLY MOD Z072 050 001 167 890 10 1 工事材料袋詰 INSTALLATION MATERRIALS CP02 09901 001 621 550 00 1 図書 DOCUMENT 装備要領書 英 INSTALLATION MANUAL EN IME 20410 000 199 256 1 1 略図の寸法は 参考値です DIMENSIONS IN DRAWING FOR REFERENCE ONLY C2041 Z01 A A 1 ...

Page 10: ...3 Feb 2022 H MAKI D 1 ...

Page 11: ... ࢳࣕ ࢩࣟ 5 1 1 1 1 1 1 8 7 㺖㺹 㺚㺹 8 7 㺏㺓 㺚㺹 5 1 ࢡࣟ 9 VT 7 7 7 5B 6 5B 5B 6 5B 3 6 5 8 9 58 3 0 P 9 21 73 21 1 9 ȭ 35 6833 81 7 32 5 㟁 ࣘࢽࢵࢺ 9 ࢿࢵࢺ ࢡ㨶᥈ 1 7 25 6281 5 8 5 ࢧࢿࢵࢺࣁࣈ 7 51 7 8 8 ࡲࡓࡣ 25 08 7 81 7 21 63 ࣝࢳࣇ ࣥࢡࢩࣙࣥࢹ ࢫࣉࣞ 5 7 7 7 7 7 7 P 02 P ཷἼჾ 75 16 8 5 0 30 P 127 237 21 6 3 5 6833 ὀグ 㸯㸧㐀 ᡤᡭ㓄ࠋ 㸰㸧 ࣉࢩࣙࣥࠋ 㸱㸧ᘏ㛗ࢣ ࣈࣝ ࣉࢩࣙࣥ Pࡲ ᘏ㛗ྍࠋ 7 16 21 237 21 1 6 7 16 21 83 72 P 3 Feb 2022 H MAKI S 1 ...

Page 12: ......

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...al is elemental chlorine free FURUNO Authorized Distributor Dealer 9 52 Ashihara cho Nishinomiya 662 8580 JAPAN A FEB 2022 Printed in Japan All rights reserved B JUN 08 2022 Pub No IME 20410 B REFU DFF3 UHD 0 0 0 1 9 9 2 5 6 1 2 ...

Reviews: