background image

 

COMPONENTS

Technisches Handbuch / Technical manual

Mainboard D1527 / D1526

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for D1526

Page 1: ...COMPONENTS Technisches Handbuch Technical manual Mainboard D1527 D1526 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ... Mainboards finden Sie im Internet http www fujitsu siemens com mainboards Are there any technical problem or other question you need clarified Please contact your sales partner your sales outlet You will find further information in the manuals Safety and Warranty The latest information and updates e g BIOS update on our mainboards can be found on the Internet under http www fujitsu siemens com ma...

Page 3: ...All manuals and user guides at all guides com ...

Page 4: ...ciclado Questo manuale è stato stampato su carta da riciclaggio Denna handbok är tryckt på recyclingpapper Dit handboek werd op recycling papier gedrukt Herausgegeben von Published by Fujitsu Siemens Computers GmbH Bestell Nr Order No A26361 D1527 Z120 1 6319 Printed in the Federal Republic of Germany AG 0902 09 02 A26361 D1527 Z120 1 6319 All manuals and user guides at all guides com ...

Page 5: ...Mainboard D1527 D1526 Technisches Handbuch Technical manual German English Ausgabe September 2002 September 2002 edition All manuals and user guides at all guides com ...

Page 6: ...s manual was produced by cognitas Gesellschaft für Technik Dokumentation mbH www cognitas de Intel Pentium and Celeron are registered trademarks of Intel Corporation USA Microsoft MS MS DOS and Windows are registered trademarks of Microsoft Corporation PS 2 and OS 2 Warp are registered trademarks of International Business Machines Inc All other trademarks referenced are trademarks or registered tr...

Page 7: ...ittstelle 2 serial interface 2 11 SMB 2 SMB 1 12 Lüfter 2 Fan 2 13 Lüfter 3 Fan 3 14 LCD Bedienfeld LCD Frontpanel 15 USB C D 16 USB E F 17 Gehäuseüberwachung Intrusion 18 Wake On LAN 19 S PDIF Anschluss S PDIF Connector 20 Audio Bedienfeld Audio Frontpanel 21 CD audio in 22 Stromversorgung Prozessor Processor power supply 23 Lüfter 1 Fan 1 Optionale Komponenten Optional components Externe Anschlü...

Page 8: ...All manuals and user guides at all guides com ...

Page 9: ...on modules Upgrading 17 Installing and removing processors 17 Installing the processor with heat sink and fan 17 Upgrading main memory 19 Upgrading AGP screen controllers 20 Adding PCI cards 20 PCI bus interrupts Selecting correct PCI slot 20 Replacing lithium battery 21 BIOS update 23 BIOS Recovery Recovering System BIOS 23 Microcode Update 24 Drivers 25 Annex 26 Electrical Properties 26 Loadabil...

Page 10: ...All manuals and user guides at all guides com ...

Page 11: ...ollows indicates information which is important for your health or for preventing physical damage i indicates additional information which is required to use the system properly Ê Text which follows this symbol describes activities that must be performed in the order shown Ë This symbol indicates that you must enter a blank space press the Space Bar at this point Ú This symbol indicates that you m...

Page 12: ...ent damage to the mainboard the components and conductors on it please take great care when you insert or remove boards Take great care to ensure that extension boards are slotted in straight without damaging components or conductors on the mainboard or any other components for example EMI spring contacts Remove the plug from the mains outlet so that system and mainboard are totally disconnected f...

Page 13: ...nal ports DIMM Sockets DDR SDRAM PC2100 2700 2 2 AGP Slot 2 4x 32 bit 66 MHz 1 5 V 1 1 PCI slot 32 bit 33 MHz 5 V and 3 3 V 6 6 CNR Slot Type A AC 97 only IDE Interface Ultra DMA 100 2 2 Floppy Interface up to 2 88 MB 1 1 S PDIF digital audio 1 1 CD AUX audio input 1 1 Frontpanel Audio headphone microphone 1 1 Wake On LAN USB Ports 2 0 480 Mb s 4 4 Serial Ports FIFO 16550 compatible 1 1 Fan Connec...

Page 14: ...ol and monitoring system prevents unnecessary noise Should the processor nevertheless become too hot at the maximum fan speed then the processor clock rate will automatically be reduced so that the system continues to run stably In addition the microcontroller offers monitoring of for example system voltages 12 V 5 V CMOS opening of the case and a watchdog function The microcontroller operates ind...

Page 15: ...or components and triggers alarms if necessary depending on the mainboard variant DeskFlash carries out a BIOS update under Windows Recovery BIOS If an error occurs during a BIOS update e g due to a power failure the system BIOS will be destroyed All Fujitsu Siemens Computers mainboards are equipped with a recovery BIOS With it a destroyed BIOS can easily be restored Exact instructions are provide...

Page 16: ...r the processor memory modules and power supply are suitable for this mainboard see Installing and removing processors chapter see Upgrading main memory chapter see Electrical Properties chapter Ê Make sure the current requirement of the fans processor case does not exceed the loadability of the fan connections see chapter entitled Electrical Properties Ê First only install the components absolute...

Page 17: ...onnections are suitable for the mainboard later Ê Set the mainboard on the edge on which the connection field is located 2 and then insert the board in the case 3 Make sure that spacers in the housing are only mounted at points at which there are mounting holes in the mainboard Ê Fasten the mainboard with the screws Ê Connect the plugs for the power supply control panel and drives to the correspon...

Page 18: ... out light green Microphone jack mono pink Audio input Line in light blue VGA port blue monitor LAN connector This mainboard is equipped with the 82562ET D1526 or the 82562EM D1527 LAN controller The LAN controller is equipped with a 3 KB transmission and receiving buffer FIFO and supports WOL function through Magic Packetä It is also possible to boot a device without its own boot hard disk via LA...

Page 19: ...resh rate Hz bpp Colour 640 x 480 120 32 32 bit 800 x 600 120 32 32 bit 1024 x 768 100 32 32 bit 1280 x 1024 100 32 32 bit 1600 x 1200 100 32 16 bit 1920 x 1440 75 32 16 bit 2048 x 1536 60 32 16 bit Internal ports and connectors The positions of the internal ports and connectors are shown on the Cover Additional information on some ports is also provided here Hard disk connection An ultra ATA 66 o...

Page 20: ...ep Reset 1 Power On LED1 3 Sleep LED Speaker Message LED Connection Note Reset Sleep This connection is reserved for future use Power On Off HD LED SCSI Activity Input Attention Do not connect to the LED connections of an SCSI controller This connection is intended for a cable with a 4 pin connector An SCSI controller reports activity low active via this cable Message LED Power On LED Indicates th...

Page 21: ... GND 8 Powergood high asserted 18 5 V P5VN 9 5 V Auxiliary VCC Aux 19 5 V VCC 10 12 V P12VP 20 5 V VCC Stromversorgungsüberwachung Power control system monitoring 1 Pin Signal 1 AC Outlet high asserted 2 PS FAN Control PS FAN C max 3 mA 3 Reserved 4 PS FAN Sense 5 SMB CLK 6 SMB DATA 7 VCC EEPROM 3 3 V 8 GND Power On LED II 1 3 Pin Signal 1 Power On LED Anode 2 Power On LED Anode 3 Power On LED Cat...

Page 22: ...2 SMB_PIC_CLK_H 3 SMB_PIC_DATA_H 4 GND Lüfter 1 Fan 1 system fan supervised 1 Pin Signal 1 GND 2 Controlled Fan voltage 0 V 6 V 12 V max 1 A or fix Fan voltage 12 V max 1 A 3 Fan sense Lüfter 2 Fan 2 system fan supervised 1 Pin Signal 1 GND 2 Controlled Fan voltage 0 V 6 V 12 V max 1 A or fix Fan voltage 12 V max 1 A 3 Fan sense All manuals and user guides at all guides com ...

Page 23: ...DATA 4 GND 5 Key 6 RFU Reseved for Future Use 7 LAN Active Icon 8 LAN Link Icon 9 Harddisk Action Icon 10 BMC Alert Icon 11 Message Icon 12 Sleep Icon 13 Power Icon 14 P3V3P DUAL USB C D E F dual channel internal or external via special wire 1 2 11 12 Pin Signal Pin Signal 1 Key 2 Chiprcardreader on 3 VCC C 4 VCC D 5 Data negative C 6 Data negative D 7 Data positive C 8 Data positive D 9 GND 10 GN...

Page 24: ... 1 GND 2 Case open low asserted 3 Intrusion switch present low asserted Audio S PDIF 1 Pin Signal 1 GND 2 SPDIF out Audio Bedienfeld Audio front panel 1 2 Pin Signal Pin Signal 1 Micro input 2 Analog GND 3 Micro bias 4 Analog VCC 5 Right line output 6 Right line return 7 NC 8 Key 9 Left line output 10 Left line return All manuals and user guides at all guides com ...

Page 25: ...1 6319 English 15 CD ROM audio 1 Pin Signal 1 Left CD audio input 2 CD GND 3 CD GND 4 Right CD audio input Prozessor Stromversorgung Processor power Supply 1 3 Pin Signal Pin Signal 1 GND 3 12 V 2 GND 4 12 V All manuals and user guides at all guides com ...

Page 26: ...m and BIOS Setup password must be entered when the device is switched on Recovering System BIOS switch 2 Switch 2 enables recovery of the old system BIOS after an attempt to update has failed To restore the old system BIOS you need a Flash BIOS Diskette please call our customer service centre On The System BIOS executes from floppy drive A and the inserted Flash BIOS Diskette restores the System B...

Page 27: ... the processors supported by this mainboard is available on the Internet at www fujitsu siemens de mainboards Installing the processor with heat sink and fan Ê Remove the fan that there may be and the heat sink 3 2 1 A 4 5 3 2 1 A 4 5 Ê Pull the lever in the direction of the arrow 1 and lift it as far as it will go 2 Ê Remove the old processor from the socket 3 Insert the new processor in the sock...

Page 28: ...oxed may be used Otherwise the retaining clips of the heat sink will be damaged When using an Intel Boxed heat sink the mainboard must be converted This conversion set is either included with the mainboard or is available separately If no counter plate is mounted you can use both Intel Boxed heat sinks and standard heat sinks If you use the Intel Boxed heat sink the mainboard will bend due to the ...

Page 29: ... www fujitsu siemens de mainboards At least one memory module must be installed Memory modules with different memory capacities can be combined You may only use unbuffered 2 5 V memory modules Buffered memory modules are not supported DDR DIMM memory modules must meet the PC2100 or PC2700 specification Installing a memory module 2 2 Ê Push the holders on each side of the memory compartment outward...

Page 30: ...ge to the mainboard and the AGP screen controller Adding PCI cards Technical data 32 bit 33 MHz PCI slots 5 V and 3 3 V supply voltage 3 3 V auxiliary voltage PCI bus interrupts Selecting correct PCI slot i To achieve optimum stability performance and compatibility avoid the multiple use of ISA IRQs or PCI IRQ Lines IRQ sharing Should IRQ sharing be unavoidable then all involved devices and their ...

Page 31: ...lots that have an unsplitted PCI IRQ Line If you must use another PCI slot with IRQ sharing check whether the expansion card properly supports IRQ sharing with the other devices on this PCI IRQ Line The drivers of all cards and components on this PCI IRQ Line must also support IRQ sharing Replacing lithium battery In order to permanently save the system information a lithium battery is installed t...

Page 32: ...fferent designs that function in the same way 2 3 3 1 2 3 Ê Press the locking lug in the direction of the arrow the battery jumps somewhat out of the holder 1 Ê Remove the battery 2 Ê Insert a new lithium battery of the same type into the socket 3 All manuals and user guides at all guides com ...

Page 33: ...update floppy disk is created Leave this floppy disk in the drive Ê Restart the PC Ê Follow the instructions on screen i Detailed information on the BIOS update under DOS is provided in the manual on BIOS Setup Drivers Utilities CD 2 BIOS update under Windows with DeskFlash utility A BIOS update can also be carried out directly under Windows with the DeskFlash utility DeskFlash is located on the D...

Page 34: ...rected and the performance to be increased To guarantee the best possible performance and error free operation Intel recommends updating the microcode regularly Intel refers to the use of the processor without regular microcode updates as operation outside the specifications Safety for processor on Fujitsu Siemens Computers mainboards If the processor uses an old or incorrect microcode error free ...

Page 35: ...read out Ê Press the F1 key in the BIOS Setup The entry CPU Patch ID is shown on the displayed information page A list with the current processors and the related Patch IDs is available on the Internet i If the processor is not recognised you also require the microcode update tool for processors of the P6 family Drivers Only when no drivers are installed on your system or you want to update these ...

Page 36: ... the fuses reset to the original state Mainboard current requirement You require a Pentium4 power supply nit as per the ATX12V specification for this mainboard If you do not have a PC from Fujitsu Siemens Computer make sure that the power supply unit provides the required amperages Source Voltage Maximum difference Maximum current ATX12V power supply 12 V 5 3 6 8 A ATX12V power supply 12 V 10 0 05...

Page 37: ...iate ly Maximum energy saving mode Save to DRAM S3 Off On flashin g RAM wake up component s ca 5s Maximum energy saving mode Save To Disk G1 S4 Off Off Off Wake up component s ca 20s Soft Off G2 S5 Soft Off Off Off Off To Nearly zero Full boot time Mechanicall y Off G3 Off Off Off Off Off Zero Full boot time G Global status S System status The power supply unit must provide sufficiently loadable 5...

Page 38: ...itsu siemens de mainboards Mainboard Revision level The revision status of the mainboard exactly identifies which mainboard you have It is indicated on a sticker on the edge of the mainboard Example of revision status of the mainboard D1522 B10 GS50 BIOS version The BIOS version can be displayed in the BIOS Setup Ê Press F2 during booting to open the BIOS Setup Ê Press F1 The BIOS version is speci...

Page 39: ...ether you want to perform the update with n Ú Ê To carry out the Flash BIOS update for the processor enter flashbioË p6 Ú Check date and time settings The system date and time are invalid Set the current date and time in the Main menu of the BIOS Setup CPU ID 0x failed Switch the server off and on again If the message is still displayed go into the BIOS setup and set the corresponding processor to...

Page 40: ...Drive A run SETUP Incorrect Drive B run SETUP Correct the entry for the diskette drive in the Main menu of the BIOS Setup Invalid NVRAM media type Switch the device off and on again If the message is still displayed please contact your sales outlet or customer service centre Invalid System Configuration Data In the Advanced menu of the BIOS Setup set the entry Reset Configuration Data to Yes Inval...

Page 41: ...ation used By pressing function key F2 you can check and correct the settings in BIOS Setup By pressing function key F1 the system starts with incomplete system configuration If the message is still displayed please contact your sales outlet or customer service centre Real time clock error Call the BIOS Setup and enter the correct time in the Main menu If the message is still displayed please cont...

Page 42: ...If the message is still displayed please contact your sales outlet or customer service centre Uncorrectable ECC DRAM error DRAM Parity error Unknown PCI error Switch the device off and on again If the message is still displayed please contact your sales outlet or customer service centre Verify CPU frequency selection in Setup The frequency setting for the processor is invalid Correct the BIOS Setu...

Page 43: ...eader and the mainboard must be checked or the SmartCard reader must be replaced While the error is present access to the system is blocked Non authorized chipcard The Sicrypt SmartCard cannot be used on this PC The Sicrypt SmartCard has been configured for a different PC PC Lock installation FAIL An error has occurred during installation of PC Lock Do not switch off but insert the BIOS Flash disk...

Page 44: ...Random Access Memory Digital Analogue Converter CPU Central Processing Unit RDRAM Rambus Dynamic Random Access Memory CNR Communication Network Riser RIMM Rambus Inline Memory Module C RIMM Continuity Rambus Inline Memory Module RTC Real Time Clock DIMM Dual Inline Memory Module SB Soundblaster ECC Error Correcting Code SDRAM Synchronous Dynamic Random Access Memory EEPROM Electrical Erasable Prog...

Reviews: