background image

En-1

PART No. 9333003030-02

English

AIR CONDITIONER
Wall Mounted Type

OPERATING MANUAL

Before using this product, read these instructions thoroughly and keep this manual for future reference.

A garantia contratual somente é válida para produtos instalados por assistência técnica credenciada.

Safety Precautions

To prevent personal injury to others, or property damage, read this section carefully before you use this product, and be sure to comply following 

safety precautions.

Incorrect operation due to failure to follow the instructions may cause harm or damage, the seriousness of which is classified as follows:

 

WARNING

 

CAUTION

This mark warns of death or serious injury.

This mark warns of injury or damage to property.

 This mark denotes an action that is PROHIBITED.

 This mark denotes an action that is COMPULSORY.

 

WARNING

• This unit contains no user-serviceable parts. Always consult 

authorized service personnel for repairing, installation, and 

relocation of this product.

  Improper installation or handling will cause leakage, electric 

shock, or fire.

• In the event of a malfunction such as burning smell, 

immediately stop operation of the air conditioner, and 

disconnect all the power supply by turning off the electrical 

breaker or disconnecting the power plug. Then consult 

authorized service personnel.

• Take care not to damage the power supply cable.

  If the supply cord is damaged, it must be replaced by the 

manufacturer, its service agent or similarly qualified persons 

in order to avoid a hazard.

• In the event of refrigerant leakage, be sure to keep away from fire 

or any flammables, and consult authorized service personnel.

• If you see lightning or hear thunder, there might be a lightning strike.

  To prevent electric shock hazard, turn off the air conditioner 

by using the remote controller, and do not touch the unit or 

the power plug during thunderstorm.

• Do not install the unit in area filled with mineral oil such as a 

factory or area containing a large amount of splashed oil or 

steam such as a kitchen.

• Do not start or stop the operation of this product by inserting 

or pulling out the power plug, or by turning on or off the 

circuit breaker.

• Do not use inflammable gases near the unit.
• Do not expose yourself directly to the cooling airflow for many hours.
• Do not insert your fingers or any other objects into outlet 

port, open panel, or intake grille.

• Do not operate with wet hands.

 

CAUTION

• Provide occasional ventilation during use.
• Always operate the unit with air filters installed.
• Ensure that any electronic equipment is at least 1 meter 

away from either the indoor unit or outdoor unit.

• Unplug the power supply cable when not using the indoor 

unit for an extended period.

• After long period of use, check whether the installation stand 

does not deteriorate to prevent the unit from falling down.

• The airflow direction and the room temperature should be 

carefully considered when you use this product in a room 

with infants, children, elderly or sick persons.

• This appliance is not intended for use by persons (including 

children) with reduced physical, sensory or mental 

capabilities, or lack of experience and knowledge, unless 

they have been given supervision or instruction concerning 

use of the appliance by a person responsible for their safety. 

Children should be supervised to ensure that they do not 

play with the appliance.

• Do not direct the airflow at fireplaces or heating apparatus.
• Do not block or cover the intake grille and the outlet port.
• Do not apply any heavy pressure to radiator fins.
• Do not climb on, place objects on, or hang objects from the unit.
• Do not place vase or water container on the unit.
• Do not place any other electrical products or household 

belongings under indoor unit or outdoor unit.

  Dripping condensation from the unit might get them wet, and 

may cause damage or malfunction of your property.

• Do not expose the unit directly to water.
• Do not use this product for preservation of food, plants, 

animals, precision equipment, art work, or other objects. This 

may cause quality deterioration of those items.

• Do not expose animals or plants to the direct airflow.
• Do not drink the drainage from the air conditioner.
• Do not pull the power supply cable to disconnect the plug.
• Do not touch the aluminum fins of heat exchanger built-in 

the indoor or outdoor unit to avoid personal injury when you 

install or maintain the unit.

Contents

Safety Precautions ..........................................................En-1
Indoor Unit Overview and Operations .............................En-2
Remote Controller Overview and Operations ..................En-3
Timer Operation...............................................................En-5
Human Sensor (Energy Saving) ......................................En-5
General Informations on Operation .................................En-6
Care and Cleaning...........................................................En-7
Troubleshooting ...............................................................En-9

9333003030-02_OM_EN.indd   1

10/6/2014   11:01:41 AM

Summary of Contents for 9333003030-02

Page 1: ...he cooling airflow for many hours Do not insert your fingers or any other objects into outlet port open panel or intake grille Do not operate with wet hands CAUTION Provide occasional ventilation during use Always operate the unit with air filters installed Ensure that any electronic equipment is at least 1 meter away from either the indoor unit or outdoor unit Unplug the power supply cable when n...

Page 2: ... of the vertical airflow direction louver the angle of the power diffuser moves as follows Vertical airflow direction louver Power diffuser 3 7 6 5 4 2 1 3 2 1 4 In SWING operation power diffuser does not move 7 Drain hose 8 Remote controller signal receiver CAUTION For appropriate signal transmission between remote controller and indoor unit keep the signal receiver away from the following items ...

Page 3: ... range noticeably got shorten replace the batteries and press RESET button You can quickly start operation with the following 3 steps Remote Controller Overview and Operations 1 START STOP button 2 MODE button Switches operation mode in following order AUTO COOL DRY FAN HEAT Notes in HEAT mode At the beginning of the operation the indoor unit operates at very low fan speed for about 3 5 minutes fo...

Page 4: ...peed or is stopped In FAN mode swing operation range of 1 3 or 4 7 is decided according to the airflow direction previously set before starting the swing operation Remote Controller Overview and Operations 10 SET button Adjusts the vertical airflow direction See page 5 11 SLEEP timer button Activates the SLEEP timer that helps you to fall asleep comfortably with gradual temperature control 12 Time...

Page 5: ...et time 1 hour 1 5 hour 30 min 1 C 2 C 3 C 4 C 2 C 1 C In COOL or DRY mode 90 7 m 7 m 50 50 Application range is follows Vertical angle 90 Side view Horizontal angle 100 Top view ENERGY SAVING function may not work when the room temperature is very different from the temperature defined in temperature setting such as when immediately after starting the operation About the HUMAN SENSOR Details abou...

Page 6: ...see the Operation manual for the wired remote controller When the restricted functions on the wireless remote controller are selected beeping sound will be heard OPERATION TIMER and the 3rd lamp of the indoor unit will flash Restricted functions for wireless remote controller ENERGY SAVING PROGRAM OUTDOOR UNIT LOW NOISE OPERATION ON OFF TIMER PROGRAM TIMER SLEEP TIMER POWERFUL OPERATION Multi type...

Page 7: ... the shaft until it snaps Then close the intake grille b a a b b 4 Press 4 places on the intake grille to close it completely Cleaning the air filters Mind that you have a periodical cleaning of the air filters to prevent reducing the operation efficiency of the product Using of clogged air filter with dust will lower the product performance and may cause airflow reduction or increase of operating...

Page 8: ...ry the filter throughly in shaded place 6 Reinstall the filter to the indoor unit Replace the filter once every 3 years under normal use After extended non use of the unit If you have shut down the indoor unit for 1 month or more perform the FAN operation for half a day to dry the internal parts throughly before you perform normal operation Additional inspection After long period of use accumulate...

Page 9: ...matic defrosting operation while the OPERATION indicator is flashing 6 In DRY mode the indoor unit operates at low fan speed to adjust the room humidity and may stop from time to time When the fan speed is set to QUIET the fan rotates at very low speed and the airflow is reduced In COOL mode the indoor unit fan may stop from time to time when the outdoor unit is stopped 3 When monitoring operation...