manualshive.com logo in svg
background image

System Board D2300
for RX200 S3 

Technical Manual

Edition June 2006

Содержание D2300

Страница 1: ...System Board D2300 for RX200 S3 Technical Manual Edition June 2006 ...

Страница 2: ...according to DIN EN ISO 9001 2000 To ensure a consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001 2000 cognitas Gesellschaft für Technik Dokumentation mbH www cognitas de Copyright and Trademarks Copyright 2006 Fujitsu Siemens Computers Gmb...

Страница 3: ...Environmental protection 11 3 Features 13 3 1 Overview 13 3 2 Main memory 17 3 3 PCI Bus 19 3 3 1 ISA bus resources 20 3 3 2 PCI resources 21 3 4 Screen resolution 23 3 5 Temperature system monitoring 23 3 6 Interfaces and Connectors 25 3 6 1 External ports 27 3 7 Settings with jumpers 29 4 Replacing the lithium battery 31 Abbreviations 33 ...

Страница 4: ......

Страница 5: ...n the monitor semi bold fixed font indicates values to be entered through the keyboard Key symbol indicates keys according to their representation on the keyboard If capital letters are to be entered explicitly then the Shift key is shown e g SHIFT A for A If two keys need to be pressed at the same time then this is shown by placing a hyphen between the two key symbols Quotation marks Indicates na...

Страница 6: ......

Страница 7: ...ilure to observe the guidelines in this manual and any unauthorized openings and improper repairs could expose the user to risks electric shock fire hazards and could also damage the equipment Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability Transport the device only in the antistatic original packaging or in ...

Страница 8: ...mum requirement the use of a protected LAN line of category 5 for 10 100 Mbps Ethernet and or of category 5e for Gigabit Ethernet is considered The requirements of the specification ISO IEC 11801 are to be considered Never connect or disconnect data transmission lines during a storm risk of lightning hazard Batteries V CAUTION Incorrect replacement of lithium battery may lead to a risk of explosio...

Страница 9: ...t before touching the components The equipment and tools you use must be free of static charges Remove the power plug from the power socket before inserting or removing boards containing ESDs Always hold boards with ESDs by theit edges Do not touch any exposed pins or conductors on a component Use a grounding cable designed for this purpose to connect yourself to the system unit as you install dei...

Страница 10: ...when you insert or remove boards Take great care to ensure that extension boards are slotted in straight without damaging components or conductors on the system board or any other components for example EMI spring contacts Be careful with the locking mechanisms catches centring pins etc when you replace the system board or components on it for example memory modules or processors Never use sharp o...

Страница 11: ...d be switched off until they are needed as well as during long breaks and after completion of work Packaging information Do not throw away the packaging You may need it later for transporting the system If possible the equipment should only be transported in its original packaging Information on handling consumables Please dispose of batteries in accordance with local regulations In accordance wit...

Страница 12: ...rding the return and recycling of devices and consumables within Europe can also be found in the Returning used devices manual via your local Fujitsu Siemens Computers branch or from our recycling center in Paderborn Fujitsu Siemens Computers Recycling Center D 33106 Paderborn Tel 49 5251 8 18010 Fax 49 5251 8 18015 The device must not be disposed of with domestic waste This device is labeled in c...

Страница 13: ...cond level cache ECC Support of SMP MPS 1 4 compliant 2 x VRM 11 0 onboard EVRD Main memory 8 slots for main memory FBD 533 and FBD 667 FBD Fully Buffered DIMMs memory modules 2 channel with 2 modules per channel with 512 MB 1 Gbyte 2 Gbyte and 4 Gbyte maximum 32 Gbyte of memory supports 4 way interleaved memory subsystems 4 identical memory modules have to installed at the same time ECC multiple ...

Страница 14: ...grated graphics controller SAS controller LSI 1068 with IME functionality Super I O controller SMSC DME 1737 Flash EPROM for IME firmware BIOS LAN Server Management SM internal connectors 1 IDE connector CD ROM DVD ROM 1 SATA connector USB Type C for USB port on front side I2C connector main power connector 12V 12V and 5V auxiliary supply 12V CPU power connector IPMB connector HDD activity connect...

Страница 15: ...Express x8 expansion slot The riser boards on the PCI riser board assembly convert the functionality of the system board expansion slots to a pair of slots positioned at a 90 angle from the system board There are two possible configuration Option 1 One standard half length PCI Express x8 slot One low profile half length 64 bit 100 MHz PCI X slot Option 2 One standard half length 64 bit 100 MHz PCI...

Страница 16: ...on 1 4 Server Hardware Design Guide 3 0 WfM 2 0 IPMI V2 0 ACPI 1 0b support LSI SCSI BIOS with IME Integrated Mirroring Enhanced USB keyboard mouse boot possible from CD ROM USB drive LAN console redirection support OEM logo CPU memory disable memory mirroring support Environmental protection Battery in holder Form factor 249 x 455 mm ...

Страница 17: ... registered Fully Buffered DIMMs ECC DDR2 533 667 The memory modules have to be populated in pairs Each pair must consist of identical memory modules Each memory bank and channel module must be equipped with 2 memory modules The module capacity between pairs can differ pair 1A 1B can be populated with two 512 Mbyte modules and pair 2A 2B with two 1 Gbyte modules M e m o r y B a n k 4 M o d u l e A...

Страница 18: ...the instructions below When operating in non mirror mode Install the first pair in the FBD 1A and FBD 1B slots Memory upgrade granularity is two DIMMs Observe the following channel pair sequence during installation FDB 1C FDB 1D FBD 2A FDB 2B then FDB 2C FDB 2D When operating in single DIMM mode the module should be installed in the FBD 1A slot ...

Страница 19: ...tation of the PCI outlets PCI slots The following table shows an overview of the PCI slots PCI slot 64Bit Frequency in MHz Description 1 64 bit 100 133 64 bit PCI X slot low profile 2 64 bit 133 64 bit PCIe x8 slot low profile and full size P C I e x 8 S l o t 2 P C I X 1 S l o t 1 ...

Страница 20: ... DMA can be used for your particular device Default settings are shown in bold print Device IRQ Address DMA Timer 0 040 043 Keyboard 1 060 064 Serial port COM1 4 3F8 3FF Floppy disk drive controller 6 3F0 3F5 3F7 2 Ethernet controller 7 Real time clock RTC 8 070 071 SCI interrupt 9 SMB controller 9 PS 2 mouse controller 12 Numeric processor 13 0F0 0FE IDE controller primary 14 1F0 1F7 3F6 IDE cont...

Страница 21: ...A per PCI slot The PCI interrupts INTA INTB INTC and INTD are available for each PCI slot The same interrupt can be assigned simultaneously to several PCI boards You should avoid this condition due to reduced performance If you use a setting other than Auto the Plug Play functionality of the system BIOS for the corresponding PCI boards is deactivated Auto The PCI interrupts are assigned automatica...

Страница 22: ...Request Grant Device IDSEL PCI_IRQ REQ GNT VGA Rage XL PCI_AD17 PCI_IRQA REQ 0 GNT 0 Device IDSEL PCI_IRQ REQ GNT PCIX slot 1 ESB_PXAD19 ESB_PXI RQ 2 ESB_PXI RQ 1 ESB_PXI RQ 0 ESB_PXI RQ 3 ESB_PXREQ 0 ESB_PXGNT 0 LSI 1068 ESB_PXAD21 ESB_PXI RQ 0 ESB_PXREQ 1 ESB_PXGNT 1 PCIX slot 2 PXH_PAAD19 PX_IRQ3 PX_IRQ0 PX_IRQ1 PX_IRQ2 PXH_PAREQ 0 PXH_PAGNT 0 Device IDSEL PCI_IRQ REQ GNT PCIX slot 1 PCIA_AD17 ...

Страница 23: ...amage caused by overheating In addition any unnecessary noise is also prevented by reducing the fan speed and information is provided about the system status The temperature and system monitoring are controlled by an onboard controller developed by Fujitsu Siemens The following functions are supported Temperature monitoring Measurement of the processor temperature measurement of the ambient temper...

Страница 24: ...ensor run at maximum speed to achieve the greatest possible protection of the hardware Power monitoring When voltage exceeds warning level high or falls below warning level low an alert will be generated System Event Log SEL All monitored events of the system board are signalised via the Global Error LED and recorded in the System Event Log They could be retrieved in the BIOS Setup or via ServerVi...

Страница 25: ...de USB ports 25 system board power plug 6 Top Rear system health LED indicator amber Bottom Rear UID LED indicator blue 26 Power On control connector JP1 7 GbE LAN ports 27 connector for IDE data cable 8 PCI X expansion slot 28 Intel MCH chipset north bridge 9 PCI Express x8 expansion slot 29 sytem configuration switch sw1 10 SMSC DME1737 Super I O Chipset 30 SATA connector C P U 1 C P U 2 B l a c...

Страница 26: ...lectric beep 33 Clear CMOS jumper JP2 14 System RTC battery 34 LSI 1068 onboard SAS controller 15 Bank 1 DIMM slots FBD 1A FBD 1B 35 JTAG connector 16 Bank 2 DIMM slots FBD 1C FBD 1D 36 iRMC chipset 17 Bank 3 DIMM slots FBD 2A FBD 2B 37 iPMB connector 18 Bank 4 DIMM slots FBD 2C FBD 2D 38 KVM switch connector 19 Front USB ports system board connector 39 COM2 port connector 20 Intel LGA771 processo...

Страница 27: ...port 7 VGA port 3 LEDs Global Error and Status 8 PS 2 keyboard port 4 USB port1 9 PS 2 mouse port 5 USB port 2 LED Indicator Meaning bottom Identify LED blue server is identified via ServerView top Status LED Global Error orange orange flashing indicates a prefailure indicates a failure Reasons for a failure may be overheating of one of the sensors sensor defect fan defect CPU error Software detec...

Страница 28: ...le to boot a device without its own boot hard disk via LAN Here Intel PXE is supported The LAN port serves as management interface iRMC Port and is prepared for RemoteView The LAN controller connectors are equipped with two LEDs light emitting diode indicating the transfer rate and the activity Figure 6 LAN port 1 LAN transfer rate green yellow off transfer rate 10 Mbit s or no connection green on...

Страница 29: ...ition of the jumpers Power On Control jumper 1 JP1 Clear CMOS jumper 2 JP2 1 2 default default setting by South Bridge and BMC via IPMI 2 3 debug by South Bridge only 1 2 normal not clear CMOS settings default setting 2 3 Clear CMOS settings C P U 1 C P U 2 B l a c k f o r d N B E S B 2 J P 1 J P 2 S W 1 ...

Страница 30: ...tting Switches Function Status Description SW1 1 BIOS recovery On Off Boot block enabled Normal boot SW1 2 BIOS password recovery On Off Password disabled Password enabled SW1 3 BIOS write protect On Off BIOS can only be read BIOS can both be read and written to SW1 4 CMOS clear On Off Clear CMOS settings and restore system defaults Normal CMOS settings ...

Страница 31: ...eplaced with an identical battery or a battery type recommended by the manufacturer CR2450 Do not throw lithium batteries into the trashcan It must be disposed of in accordance with local regulations concerning special waste Make sure that you insert the battery the right way round The plus pole must be on the top Bild 8 Replacing the lithium battery Ê Press the locking spring into direction of of...

Страница 32: ......

Страница 33: ... listed here are valid for the described system board ACPI Advanced Configuration and Power managament Interface ASSR Automatic Server Recovery and Restart ATA Advanced Technology Attachment BBU Battery Backup Unit BIOS Basic Input Output System BMC Baseboard Management Controller CMOS Complementary Metal Oxide Semiconductor COM COMmunication port CPU Central Processing Unit DDR Double Data Rate D...

Страница 34: ...ion Code EEPROM Electrical Erasable Programmable Read Only Memory EPROM Erasable Programmable Read Only Memory EMRL Embedded RAID Logic EVRD Enterprise VRD HPC Hot plug Controller ICE In Circuit Emulation IDE Integrated intelligent Drive Electronics IME Integrated Mirror Enhanced IOOP Intelligent Organisation Of PCI IPMB Intelligent Platform Management Bus ...

Страница 35: ...ode MPS Multi Processor Specification NMI Non Maskable Interrupt OEM Original Equipment Manufacturer OHCI Open Host Controller Interfache OS Operating System PCI Peripheral Components Interconnect PDA Prefailure Detection and Analyzing PIO Programmed Input Output PLD Programmable Logic Device PS U Power Supply Unit PWM Puls Wide Modulation ...

Страница 36: ... Board RST ReSeT RTC Real Time Clock SCSI Small Computer Systems Interfache SDDC Single Device Data Correction SDRAM Synchronous Dynamic Random Access Memory SHDG Server Hardware Design Guide SMB System Management Bus SMM Server Management Mode SMP Symmetrically Multi Processing UHCI Unified Host Controller Interface USB Universal Serial Bus ...

Страница 37: ...D2300 RX200 S3 Technical Manual 37 Abbreviations VGA Video Graphics Adapter VRD Voltage Regulator Down VRM Voltage Regulator Module WfM Wired for Management WOL Wake up On LAN ...

Страница 38: ......

Страница 39: ... Manual D2300 RX200 S3 Comments Suggestions Corrections Submitted by Fujitsu Siemens Computers GmbH User Documentation 85521 Ottobrunn Germany Fax 0 700 372 00000 email manuals fujitsu siemens com http manuals fujitsu siemens com ...

Страница 40: ......

Страница 41: ... Manual D2300 RX200 S3 Comments Suggestions Corrections Submitted by Fujitsu Siemens Computers GmbH User Documentation 85521 Ottobrunn Germany Fax 0 700 372 00000 email manuals fujitsu siemens com http manuals fujitsu siemens com ...

Страница 42: ...tsu com Copyright Fujitsu Technology Solutions 2009 Hinweise zum vorliegenden Dokument Zum 1 April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen Diese neue Tochtergesellschaft von Fujitsu trägt seit dem den Namen Fujitsu Technology Solutions Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nic...

Отзывы: