background image

 

 

 

Open Front 

Hot Food Display Cabinets

Summary of Contents for Visair IN-VH06

Page 1: ...Open Front Hot Food Display Cabinets...

Page 2: ...Products Group Limited All rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying reco...

Page 3: ...et Layout 8 Self Service Cabinets 8 Lighting 8 Controls 8 Control Panel 8 Preparation 9 Shelf Location and Ticketing 9 Power Supply 9 Pre heat the Cabinet 9 Load Cabinet 9 Operating Routines 10 Operat...

Page 4: ...er Supply 15 Power Supply Connection 15 Electrical Isolation 15 Earthing 15 SERVICING 16 Control Gear 16 Caution 16 Access to Control Gear 16 Control Gear Chassis 16 Control Gear Components 16 Cooling...

Page 5: ...elopment 22 ELECTRICAL CIRCUIT DIAGRAMS 23 Model IN VH06 A001 A003 23 Model IN VH06 A002 A004 23 Model IN VH09 A001 A003 24 Model IN VH09 A002 A004 24 Model IN VH12 A001 A003 25 Model IN VH12 A002 A00...

Page 6: ...its recommendations The time taken will be well spent These instructions both general and technical tell you how to operate and look after your inline food service cabinet so that you can receive the...

Page 7: ...od Any damage or malfunction resulting from the use of non FPG supplied spare parts Specific Exclusions The following are specifically excluded from warranty Breakage of glass or plastic components or...

Page 8: ...eights The cabinets can have flush sides and opaque side panels enabling them to be stacked side by side Lighting Cabinets are fitted with LED lighting Lighting strips are fitted in the ceiling of the...

Page 9: ...ns The front edges of the shelves and base are fitted with extrusions to carry ticketing labels Power Supply Ensure that power is connected to the cabinet Turn on the main power switch as shown above...

Page 10: ...eat the air through which it passes Accurate product temperature measurements can only be made by using a probe type thermometer as shown below Periodic checks should be made by inserting the probe in...

Page 11: ...itch ON The power switch on the unit is faulty Have the switch replaced Cabinet does not reach temperature The cabinet is in a draught Eliminate the draught Rear loading doors are open Close rear door...

Page 12: ...urfaces should be cleaned with hot soapy water DO NOT clean surfaces with abrasive pads or cleaners as stainless steel and aluminium surfaces will be damaged Glass All glass should be cleaned using a...

Page 13: ...use abrasive pads or cleaners as these may damage surfaces Warning Dishwasher detergents will damage any anodised aluminium parts Side Glass The inside of the side glass can be cleaned with the shelve...

Page 14: ...Check that all plastic film protection has been removed from surfaces otherwise it will melt when the cabinet heats up Positioning the Cabinet With the lower front and back panels removed a fork lift...

Page 15: ...ied service person The VH24 cabinet has terminals for connecting the incoming mains supply phase neutral and earth conductors The terminals are mounted at the back of the left control gear chassis Bef...

Page 16: ...agnetic catches The control gear chassis can now be accessed Control Gear Chassis Each control gear chassis can be withdrawn after removing two fixing screws Control Gear Components The left chassis h...

Page 17: ...AIR CABINETS SERVICING Alarm Indication In the event of one or more infrared elements failing the under current relay will close the digital input to the Dixell controller After one minute the Dixell...

Page 18: ...ds after removing the fixing screws Elements and lighting strips can then be replaced Check power supplies before replacing LED assemblies Shelf Light or Element Replacement Remove the shelf from the...

Page 19: ...played value DOWN To see the min stored temperature in programming mode it browses the parameter codes or decreases the displayed value To switch the instrument off if onF oFF Not enabled XR20CX Displ...

Page 20: ...Flat sides without capping see IN VH24 Electrical VISAIR CABINETS SPECIFICATIONS CABINET MODEL IN VH06 A001 3 A002 4 IN VH09 A001 3 A002 4 IN VH12 A001 3 A002 4 6 IN VH18 IN VH24 A001 IN VH24 A002 4 S...

Page 21: ...N VH09 IN VH12 A001 4 IN VH12 A006 8 IN VH18 IN VH24 IL VH24 Finder Settings Front Elements 4 min ON T2 6 min ON T2 6 min ON T2 5 min ON T2 6 min ON T2 6 min ON T2 E 0 5 10min Rear Elements 4 min ON T...

Page 22: ...ctrical Equipment IEC 335 Heated Food Cabinets AS NZS 3820 Essential Safety Requirements AS NZS 4417 Marking of Electrical Products Performance Aspects The cabinet is HACCP compliant with the followin...

Page 23: ...VH12 VH18 and VH24 23 Future Products Group ELECTRICAL CIRCUIT DIAGRAMS Model IN VH06 A001 A003 Visair Series Open front 600mm Heated Cabinet Model IN VH06 A002 A004 Visair Series Open front 600mm He...

Page 24: ...Part No 24895 Rev Y March 2018 24 Visair Heated Cabinets Model IN VH09 A001 A003 Visair Series Open front 900mm Heated Cabinet Model IN VH09 A002 A004 Visair Series Open front 900mm Heated Cabinet...

Page 25: ...H06 VH09 VH12 VH18 and VH24 25 Future Products Group Model IN VH12 A001 A003 Visair Series Open front 1200mm Heated Cabinet Model IN VH12 A002 A004 A006 A008 Visair Series Open front 1200mm Heated Cab...

Page 26: ...Part No 24895 Rev Y March 2018 26 Visair Heated Cabinets Model IN VH18 Visair Series Open front 1800mm Heated Cabinet...

Page 27: ...IN VH06 VH09 VH12 VH18 and VH24 27 Future Products Group Model IN VH24 A001 Visair Series Open front 2400mm Heated Cabinet...

Page 28: ...Part No 24895 Rev Y March 2018 28 Visair Heated Cabinets Model IN VH24 A002 A004 Visair Series Open front 2400mm Heated Cabinet...

Page 29: ...for VH 06 70531 Top Light Replacement Kit for VH 09 70703 Top Light Replacement Kit for VH12 VH24 69833 Shelf Light Replacement Kit for VH 06 70532 Shelf Light Replacement Kit for VH 09 70718 Shelf Li...

Page 30: ...34 End Glass LH Custom flat sided cabinets 68270 End Glass RH Custom flat sided cabinets 68278 Glass rear door assembly VH12 A006 72100 Glass Up stand 600 26288 Glass Up stand 900 26390 Glass Up stand...

Page 31: ...6 VH09 VH12 VH18 and VH24 31 Future Products Group MECHANICAL DRAWINGS Cabinet Variants Cabinets can be supplied in various formats Three shelf Two shelf Standard height Tall With rear loading doors I...

Page 32: ...Part No 24895 Rev Y March 2018 32 Visair Heated Cabinets IN VH09...

Page 33: ...IN VH06 VH09 VH12 VH18 and VH24 33 Future Products Group IN VH12 A001 A003 Note Model A003 is fitted with three shelves...

Page 34: ...Part No 24895 Rev Y March 2018 34 Visair Heated Cabinets IN VH12 A002...

Page 35: ...IN VH06 VH09 VH12 VH18 and VH24 35 Future Products Group IN VH12 A004...

Page 36: ...Part No 24895 Rev Y March 2018 36 Visair Heated Cabinets IN VH12 A008...

Page 37: ...IN VH06 VH09 VH12 VH18 and VH24 37 Future Products Group IN VH12 A006...

Page 38: ...Part No 24895 Rev Y March 2018 38 Visair Heated Cabinets IN VH18...

Page 39: ...8 and VH24 39 Future Products Group IN VH24 A001 Note This illustrated custom cabinet has flat sides without base capping to enable flush side mounting The cabinet can also be supplied in the format s...

Page 40: ...Part No 24895 Rev Y March 2018...

Reviews: