F8X14 Series 
User Manual 

Documentation No.

 

Product  Version

 

Page

 

 

 

 

Product Name:

 

Total:

 

 

 

 

 

 

 

 

 

F

F

F

F8

8

8

8X

X

X

X1

1

1

14

4

4

 

 

 S

S

S

Series

eries

eries

eries 

 

 

 User Manual

User Manual

User Manual

User Manual 

 

 

 

The user manual is suitable for the following model:

 

 

 

 

Model 

Product Type

 

F8114 

 GPRS IP MODEM 

F8214 

 CDMA IP MODEM 

F8314 

 EDGE IP MODEM 

F8414 

 WCDMA IP MOEM 

F8514 

 TD-SCDMA IP MOEM 

F8614 

 EVDO IP MOEM 

    

 

 

 

 

 

Xiamen Four

Xiamen Four

Xiamen Four

Xiamen Four----Faith Communication Technology Co., Ltd.

Faith Communication Technology Co., Ltd.

Faith Communication Technology Co., Ltd.

Faith Communication Technology Co., Ltd.    

Add

J1-J3,3rd Floor,No.44,GuanRi Road,SoftWare 

Park,XiaMen,China                Zip Code:361008 

Tel

+86 592-6300326 

6300325

6300324 

Fax:+86 592-5912735 

http://www.fourfaith.com

Summary of Contents for F8114

Page 1: ... F8214 ZigBee CDMA IP MODEM F8314 ZigBee EDGE IP MODEM F8414 ZigBee WCDMA IP MOEM F8514 ZigBee TD SCDMA IP MOEM F8614 ZigBee EVDO IP MOEM Xiamen Four Xiamen Four Xiamen Four Xiamen Four Faith Communication Technology Co Ltd Faith Communication Technology Co Ltd Faith Communication Technology Co Ltd Faith Communication Technology Co Ltd Add J1 J3 3rd Floor No 44 GuanRi Road SoftWare Park XiaMen Chi...

Page 2: ...rk XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 Files Revised Record Files Revised Record Files Revised Record Files Revised Record Date Version Remark Author 2011 04 19 V0 5 Draft Tracy zheng 2011 06 28 V0 6 Modification Tracy zheng 2011 07 14 V0 7 Modification Tracy zheng ...

Page 3: ...y Co Ltd Without written permission all commercial use of the files from Four Faith are forbidden such as copy distribute reproduce the files etc but non commercial purpose downloaded or printed by individual all files shall be not revised and the copyright and other proprietorship notice shall be reserved are welcome Trademark Notice Four Faith 四信 are all registered trademarks of Xiamen Four Fait...

Page 4: ... Xiamen Four Faith Communication Technology Co Ltd Page 4 of 48 Add J1 J3 3 rd Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 ...

Page 5: ...ions 8 Chapter 2 Installation Introduction 12 2 1 General 12 2 2 Encasement List 12 2 3 Installation and Cable Connection 12 2 4 Power 15 2 5 Indicator Lights Introduction 15 Chapter 3 Configuration 16 3 1 Configuration Connection 16 3 2 Configuration Introduction 16 3 3 Run the configure Tool IP Modem Configure exe 17 3 4 Re power IP MODEM 18 3 5 Configuration 18 3 5 1 Data Service Center Setting...

Page 6: ... protection Power range DC 5 35V Stability and Reliability F8X14 IP MODEM is a kind of data terminal device that provides data transfer function by public cellular network and ZigBee network It adopts high powered industrial 32 bits CPU and embedded real time operating system It supports RS232 RS485 or RS422 and ZigBee port that can conveniently and transparently connect one device to a cellular n...

Page 7: ...ic level RS232 interface can be customized Support intellectual mode enter into communication state automatically when powered Provide management software for remote management Support several work modes Convenient configuration and maintenance interface High performance Support data transfer by cellular and ZigBee network Support TCP server and support multi TCP client connection optional Support...

Page 8: ...phase 2 2 GPRS class 10 class 12 optional Bandwidth 85 6Kbps TX power GSM850 900 33dBm GSM1800 1900 30dBm RX sensitivity 107dBm F8214 Specification Item Content Cellular Module Industrial cellular module Standard and Band CDMA2000 1xRTT 800MHz CDMA800 1900MHz optional CDMA450MHz optional Bandwidth 153 6Kbps TX power 30dBm RX sensitivity 104dBm F8314 Specification Item Content Cellular Module Indus...

Page 9: ...ps DL UL TX power 24dBm RX sensitivity 109dBm F8514 Specification Item Content Cellular Module Industrial cellular module Standard and Band TD SCDMA HSDPA HSUPA 1880 1920 2010 2025MHz GSM850 900 1800 1900MHz 四频 GPRS EDGE CLASS 12 Bandwidth 2 8Mbps down 2 2Mbps up TX power 24dBm RX sensitivity 108dBm F8614 Specification Item Content Cellular Module Industrial cellular module Standard and Band CDMA2...

Page 10: ...ced version Channels 11 to 26 11 to 25 for enhanced version Max packge size 100Bytes on Broadcast workmode 1024 Bytes on Master Client and Accord workmode Hardware System Item Content CPU Industrial 32 bits CPU FLASH 512KB Extendable SRAM 256KB Extendable Interface Type Item Content Serial 1 RS232 port and 1 RS485 orRS422 port 15KV ESD protection Data bits 5 6 7 8 Stop bits 1 1 5 2 Parity none eve...

Page 11: ... 35V Power Consumption Working States Power Consumption Communication 50 90mA 12VDC 115 165mA 5VDC Standby 25mA 12VDC 45mA 5VDC Sleep 8mA 12VDC 18mA 5VDC Timing Power Off 0 6mA 12VDC 1mA 5VDC Physical Characteristics Item Content Housing Iron providing IP30 protection Dimensions 91x58 5x22 mm Weight 210g Environmental Limits Item Content Operating Temperature 25 65ºC 13 149 Extended Operating Temp...

Page 12: ...n Introduction 2 1 General The IP MODEM must be installed correctly to make it work properly Warning Forbid to install the IP MODEM when powered 2 2 Encasement List Name Quantity Remark IP MODEM host 1 2 4G ZigBee Antenna 1 Cellular Antenna 1 Power adapter 1 RS232 data cable 1 optional RS485 data cable 1 optional Manual CD 1 Certification card 1 Maintenance card 1 Table 2 1 Encasement List 2 3 Ins...

Page 13: ...ide and insert card sheath back to the SIM UIM card outlet Warning Forbid to install SIM UIM card when powered Installation of antenna Screw the SMA male pin of the antenna to the female SMA outlet of the IP MODEM tightly Warning The antenna must be screwed tightly or the signal quality of antenna will be influenced User Interface Signal Definition Pin Number Signal Name Default Function Extensibl...

Page 14: ...e pulse wave input counter ADC and pulse output Installation of cable F8X14 adopts industrial terminal block interface The recommendatory cable is 28 16AWG The detail description of standard layout adapter and communication cables as is following Adapter Rating Output 12VDC 0 5A Cable Color Power Output Polarity Black White Alternate Anode Black Cathode RS232 Cable Cable Color Corresponding DB9 M ...

Page 15: ...5 Indicator Lights Introduction The IP MODEM provides three indicator lights Power ACT Online Indicator Light State Introduction Power ON IP MODEM is powered on OFF IP MODEM is powered off ACT BLINK Data is communicating OFF No data Online ON IP MODEM has logged on network OFF IP MODEM hasn t logged on network ZigBee ON ZigBee Transport data OFF No data Communication Interface RS232 Communication ...

Page 16: ...ction There are two ways to configure the IP MODEM Configuration software tool All the settings are configured through the shipped software tool It s necessary to have one PC to run this tool Extended AT command All the settings are configured through AT command so any device with serial port can configure it Before configuration with extended AT command you should make IP MODEM enter configure st...

Page 17: ...al Parameters column shows the current serial port settings To configure IP MODEM please choose the correct serial port which connects to IP MODEM and the baud rate is 115200 with no parity then open the serial port If the button text is Close it shows the serial port now has been opened If the text is Open you should open the port first When the port opened the Output Info column will display Por...

Page 18: ...l load current settings from IP MODEM and displays on the right configure columns It s now ready to configure 3 5 Configuration F8114 for example 3 5 1 Data Service Center Settings Settings on this page are the parameters related to Data Service Center DSC Data Center Number IP MODEM support two Data Service Center methods to transmit data Main and Backup IP MODEM always tries to connect with the ...

Page 19: ...in Multi Data Service Center method GPS data transmission DSC is self governed Setting details please reference the section 3 5 5 AT command AT SVRCNT x x Data Service Center number Note every AT command is terminated with a enter character Main Center Addr Port IP Address and Port of the Main DSC It s better to set the port greater than 1024 AT command of the Main DSC IP address or domain name AT...

Page 20: ...domain name AT Command of the 2 5 DSC port AT PORTn xxx n is 1 4 correspond to port of center 2 5 xxx The port value Example Set IP address of center 3 as 166 111 8 238 and port 5001 the AT command is as following AT IPAD2 166 111 8 238 AT PORT2 5001 Main and Backup Center DNS Server When the DSC Internet access uses domain name It s necessary to set DNS server resolving the DSC domain name When t...

Page 21: ...e to choose PROT Heartbeat packet with TCP protocol Data transmission with TCP protocol heartbeat packet and application data transmission are in the same TCP connection TRNS IP MODEM work as a common GPRS MODEM It can be used in SMS CSD Dial up applications TTRN Heartbeat packet with UDP protocol Data transmission with TCP protocol TLNT IP MODEM work as a telnet client LONG Heartbeat packet with ...

Page 22: ...n the software can makes IP MODEM into sleep state in idle time When there is application data to transmit IP MODEM can be triggered online ready for data transmission There are total five methods to make IP MODEM online AUTO IP MODEM always keeps online SMSD send a special short message to make IP MODEM online CTRL make IP MODEM online through a phone call to IP MODEM DATA send special serial dat...

Page 23: ...s this value should set to 0 or 1 the default value is 1 Databit Parity Stopbit 8N1 8 Databit No parity 1 Stopbit 8E1 8 Databit Even parity 1 Stopbit 8O1 8 Databit Odd parity 1 Stopbit AT Command AT SERMODE xxx xxx one of the above serial mode Communication Baudrate 110 110 bps 300 300 bps 600 600 bps 1200 1200 bps 2400 2400 bps 4800 4800 bps 9600 9600 bps 14400 14400 bps 19200 19200 bps 38400 384...

Page 24: ...is item is set to 1 IP MODEM will check whether the main center work fine timely When it detects the main server work fine it will return back to the main server at once AT Command AT RETMAIN x x 0 or 1 Device ID The identity number of IP MODEM the value should be 8 bytes hex decimal characters AT Command AT IDNT aabbccdd aabbccdd the identity number of IP MODEM SIM Card No The phone number of the...

Page 25: ...T It s the self defined register string It can be empty the maximum length is 70 bytes AT Command AT CONNRGST xxx xxx self defined register string Custom Heartbeat String This item is only valid when the WorkMode is TCST It s the self defined heartbeat string It can be empty the maximum length is 70 bytes AT Command AT LINKRGST xxx xxx self defined heartbeat string Connect Retry Times Reconnect Ti...

Page 26: ...ct to the center Reconnect Time Interval AT Command AT RDLWT xxx xxx the sleep time until next retry Transfer meanning 0 Yes enable transfer meaning 1 No disable transfer meaning This item is only valid when the WorkMode is PROT If this item is set to 0 IP MODEM will transfer meaning to 0xfd and 0xfe To know detail transfer meaning method please refer IP MODEM Transfer Meaning Explanation In the P...

Page 27: ...del APN Username and password Call center F8114 Cmnet null 99 1 F8214 null card 777 F8314 cmnet null 99 1 F8414 3gnet null 99 F8514 cmnet null 98 1 F8614 null card 777 AT Command of APN AT APN xxxx xxxx access point name AT Command of Username AT USERNAME xxx xxx username AT Command of Password AT PASSWORD xxx xxx password AT Command of Call Center AT CENT xxx xxx call center phone number of ISP S...

Page 28: ...s in idle state until it receives the trigger phone call then it will connect to the center AT Command AT CTRLNO xxx xxx trigger phone number SMS Trigger Password This item is valid only when the Trigger Type is SMSD or MIXD IP MODEM will keeps in idle state until it receives the trigger short message Then it will connect to the center AT Command AT SMSDPSWD xxx xxx SMS content to trigger IP MODEM...

Page 29: ... AT DOFFPSWD xxx xxx data trigger off password TCP MTU The maximum transmission unit of TCP packet AT Command AT TCPMTU xxx xxx the MTU value Multi Center Reconnect Interval This item is valid only when the Data Center Number is greater than 1 When one of the configured data center lost connection IP MODEM will try to reconnect after the configured reconnect interval AT Command AT MCONTIME xxx xxx...

Page 30: ...ing Press Set you will see the follow window you can do the setting AT Command AT EXCALx options value1 value2 value3 Options D Disabled Scheduled Power On Off function is disabled Default O On Set the IP Modem power on time S Shut Down Set the IP Modem power off time Setting type IP use for power on C use for power off T Time Set the action time point H per Hour Set a time point of every hour D p...

Page 31: ...5 6300324 Fax 86 592 5912735 1 Disable AT Command AT EXCALx D Note There is no blank in this AT command the same as followings 2 On time switch power on AT Command AT EXCALx OT strLongTime holdTime strLongTime Format 2010 08 01 12 30 00 holdTime Hold time value Unit Second For example IP Modem power on at 12 30 00 and power off at 13 30 00 on August 1st 2010 AT EXCAL5 OT 2010 08 01 12 30 00 3600 ...

Page 32: ...aith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 3 Power on per hour AT Command AT EXCALx OH strTime holdTime strTime Format 00 30 00 holdTime Hold time value Unit Second For example IP Modem power on at the 30th minute in every hour and power off 10 minutes later AT EXCAL1 OH 00 30 00 600 4 Power on per day AT Command AT EXCALx OD strTime holdTime ...

Page 33: ...P Modem power On at 09 00 00 everyday and power off 1 hour later AT EXCAL3 OD 09 00 00 3600 5 Power on per week AT Command AT EXCALx OW week strTime holdTime week 0123456 replace to Sunday Monday Tuesday Wednesday Thursday Friday and Sunday ordinal strTime Format 12 30 00 holdTime Hold time value Unit Second For example IP Modem power on at 09 00 00 on every Wednesday and Friday and power off 1 ho...

Page 34: ...a http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 AT Command AT EXCALx OM date strTime holdTime date 0 31 strTime Format 12 30 00 holdTime Hold time value Unit Second For example IP Modem power on at 09 00 00 on the 28th every month and power off 1 hour later AT EXCAL3 OM 28 09 00 00 3600 7 Power on with time interval ...

Page 35: ...t Minute holdTime Hold time value Unit Second For example IP Modem power on interval every 10 minutes and power off 120 seconds later AT EXCAL1 OP 10 120 8 IP Modem online offline with time interval AT Command AT EXCALx OP intervalTime holdTime intervalTime interval time value Unit Minute holdTime Hold time value Unit Second For example IP Modem online interval every 10 minute and offline 120 seco...

Page 36: ...e 36 of 48 Add J1 J3 3 rd Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 AT Command AT EXCALx ST strTime 10 Power off per hour AT Command AT EXCALx SH strTime 11 Power off per day ...

Page 37: ... J1 J3 3 rd Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 AT Command AT EXCALx SD strTime 12 Power off at the same time in every week AT Command AT EXCALx SW week strTime 13 Power off per month ...

Page 38: ...a http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 AT Command AT EXCALx SM date strTime 14 Power off with countdown AT Command AT EXCALx SC afterTime afterTime Countdown value Unit Second For example IP Modem power off 600 seconds later AT EXCAL1 SC 60 Note If the aftertime is 0 the IP Modem will power off immediately ...

Page 39: ... 0 to 65535 2 Now provision a unique MAC Node Identifier into each module The unique Node Identifier can be selected from the range of 0 to 65533 Note that Node 0 in a full mesh network does not have any supremacy over other nodes any more A full mesh network can operate even without Node 0 3 Turning on devices For a full mesh network devices can be turned on at any arbitrary order 4 Validating co...

Page 40: ...5 n RF Channel frequency band 11 11 2 405GHz 12 12 2 410 GHz 13 13 2 415 GHz 14 14 2 420 GHz 15 15 2 425 GHz 16 16 2 430 GHz 17 17 2 435 GHz 18 18 2 440 GHz 19 19 2 445 GHz 20 20 2 450 GHz 21 21 2 455 GHz 22 22 2 460 GHz 23 23 2 465 GHz 24 24 2 470 GHz 25 25 2 475 GHz 26 26 2 480 GHz RF Power Setting AT Command AT ZPOWER n n RF Power 0 0 dBm 1 1 dBm 3 3 dBm 5 5 dBm 7 7 dBm 10 10 dBm 15 15 dBm 25 2...

Page 41: ...vice has Same NET ID can work in the same Mesh Network AT Command AT ZNETID n n 0 65535 Device Addr Setting All nodes in the same Mesh Network has a unique Short Mac Address as the Device Address The Master s Short Mac Address is always 0 AT Command AT ZSHORTMAC n n 0 65533 Transparent Addr Setting AT Command AT ZDSTADDR n n 0 65533 65535 Command AT ZDSTADDR 65535 means the message transfer with b...

Page 42: ...nly in data Transparent transmission mode effect The default of 0 COM ZigBee Network AT Command AT TYPE n n 0 1 2 3 0 COM ZigBee Network 1 COM ZigBee 2 COM Network 3 ZigBee Network In data transmission mode according to the protocol shall be invalid and must be set to 0 Trans Mode Setting Sets of Transfer mode of device The information of Broadcast mode and Master Client mode is Transparent transm...

Page 43: ...tings Show Config Show current IP MODEM settings Show Baudrate Display the communication baudrate Auto Detect Simple way to determine whether IP MODEM work fine Save Output Save the output info to a file Save Config Save the current settings to a file you can restore it from this file later Restore Config Restore settings from a previous saved configure file 3 7 Work State Switch This tool can wor...

Page 44: ...tWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 Communication This state is used as a common serial communication tool Reboot Device Enter Communication State This function button is used to reboot IP MODEM and make the software switch to Communication state ...

Page 45: ...325 6300324 Fax 86 592 5912735 Appendix The following steps describe how to make IP MODEM enter configure state with the Windows XP Hyper Terminal 1 Press Start Programs Accessories Communications Hyper Terminal 2 Input connection name choose OK 3 Choose the correct COM port which connect to IP MODEM choose OK 4 Configure the serial port parameters as following choose OK Bits per second 115200 ...

Page 46: ...361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 Data bits 8 Parity None Stop bits 1 Flow control None 5 Complete Hyper Terminal operation It runs as following 6 Re power IP MODEM put mouse focus on the Hyper Terminal and press s key continuously until IP MODEM enter configure state as following ...

Page 47: ... Ltd Page 47 of 48 Add J1 J3 3 rd Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 7 IP MODEM has entered configure state you can configure the parameters through AT command ...

Page 48: ...trolCode Node1 Addr Frame length Valid data XOR 3Byte 1Byte 2Byte 2Byte 1Byte 3 The Node2 Data format Frame head ControlCode Node1 Addr Frame length Valid data XOR 3Byte 1Byte 2Byte 2Byte 1Byte Frame head by three characters Control Code indicates the node receiving data sent to what equipmen 0x01 Send to UART 0x02 Send to ZigBee 0x04 Send to Network Frame length The whole length of data frame Val...

Reviews: