manualshive.com logo in svg
background image

Operations Manual

Electronic Gas Flow Computer

Smith Meter 

®

 

microFlow.net

 Gas

Issue/Rev. 0.0 (2/10) 

 

 

 

 

 

 

 

                 Bulletin MNFG003

The Most Trusted Name In Measurement

Содержание Smith Meter microFlow.net Gas

Страница 1: ...Operations Manual Electronic Gas Flow Computer Smith Meter microFlow net Gas Issue Rev 0 0 2 10 Bulletin MNFG003 The Most Trusted Name In Measurement ...

Страница 2: ...he inputting of incorrect or improper program or default values entered in connection with the microFlow net Gas Proprietary Notice This document contains information that is proprietary to FMC Technologies Measurement Solutions Inc and is available solely for customer information The information herein shall not be duplicated used or disclosed without prior permission of FMC Technologies Measurem...

Страница 3: ... Mode 8 Overview 8 Resetting Starting a New Batch 8 Stopping the Flow Using the Keypad 8 Keyboard Functions 8 Section IV Program Mode 9 Program Mode 9 Keyboard Data Entry 9 Entry to Main Directories 10 Changing Program Mode Parameters 11 Numeric Data 11 Alphanumeric Data 11 Section V Diagnostics 12 Main Menu Diagnostics 12 Ultrasonic Diagnostics 23 Section VI Index 27 Section VII Related Publicati...

Страница 4: ...ii ...

Страница 5: ...lumetric correction and energy are calculated using published AGA ISO equations providing precise measurement results The dynamic real time display of the current actual operating conditions of the system provides the operator with valuable system information while the system is operating The microFlow net Gas provides several features Ethernet Connectivity Three Multi Drop Serial Communications P...

Страница 6: ...essages that would initially occur The Run Mode section describes the typical operation of a microFlow net Gas and the read only Diagnostics The Program Mode section describes the mechanics of marking configuration changes to a microFlow net Gas using the integral display and keypad See the Reference Manual for details of the parameters that are affected in the Program Mode The Index is a comprehe...

Страница 7: ...mmunications ports or via the display and keypad found on the face of the instrument The display and keypad alter the format and function based upon the mode Run Mode Programming Mode that the instrument is currently operating in The following provides previews to the various screens as well as the keypad functions associated with the various modes Figure 1 microFlow net Gas Display and Controls ...

Страница 8: ...e ALARM message will blink at the bottom of all run time screens if an alarm conditions exists Otherwise the MORE message will be present at the bottom of all run time screens Once the initial screen is displayed the operator can scroll through other run time screens by pressing the right left cursor buttons This will sequence through the following screens If the programming calls for a user confi...

Страница 9: ... Flow XXXX MSCF h Average Reverse Flow XXXX MSCF h MORE microFlow net Gas Mass Batch Forward 0 kg Mass Batch Reverse 0 kg MORE microFlow net Gas Energy Batch Forward 0 MMBtu Energy Batch Reverse 0 MMBtu MORE Energy Flow Rate Current Forward Flow 0 0 MMBtu h Current Reverse Flow 0 0 MMBtu hF MORE Energy Flow Rate Average Forward Flow 0 0 MMBtu h Average Reverse Flow 0 0 MMBtu h MORE ...

Страница 10: ...GY 0 00 MMBtu MORE Batch Forward GV 0 00 MCF GSV 0 00 MSCF MASS 0 00 kg ENERGY 0 00 MMBtu Batch Reverse GV 0 00 MCF GSV 0 00 MSCF MASS 0 00 kg ENERGY 0 00 MMBtu MORE Non Resets Forward GV 0 00 MCF GSV 0 00 MSCF MASS 0 00 kg ENERGY 0 00 MMBtu MORE Non Resets Reverse MORE XXX X F Current Temperature XXX X F Average Temperature Note This screen will not be displayed if a temperature input is not conf...

Страница 11: ...e This screen will not be displayed if temperature compensation is not configured Cur Ref Dens 0 0000 Cur Obs Dens 0 0000 Average Ref Dens 0 0000 Average Obs Dens 0 0000 Average Rel Dens 0 0000 MORE Density kg m3 MORE 0 00 bar Current Pressure 0 00 bar Average Pressure Note This screen will be displayed only if live pressure is configured ...

Страница 12: ...pted for the passcode enter the programmed passcode set in the programming Step 4 A new batch will now begin as the RUN MODE totalizers reset to zero 0 and begin incrementing as flow is present Stopping the Flow Using the Keypad The only way to stop the flow locally at the keypad using the digital control valve is to enter the program mode and set the flow rate to zero 0 This operation is not prac...

Страница 13: ... Manual MNFG002 Keypad Data Entry The push buttons on the keypad perform the following functions while the instrument is in the Program Mode 0 9 Used to enter the access code and data entries CLEAR Used for clearing incorrect entries or for getting to an exit point ENTER Used to enter the Program Mode security access code to enter the subdirectory and to enter program data START Not used in Progra...

Страница 14: ...rocedure checks for the proper access code If it is correct the following will be displayed 6 If an incorrect access code was entered an Access Denied CLEAR re enter message will appear Press CLEAR to return the display to the Enter Pass code Screen in Step 3 Repeat Steps 3 4 and 5 to re enter Program Mode Main Menu microFlow net Gas Reset Batch Dynamic Displays Print Menu Program Mode Menu Diagno...

Страница 15: ...sages Prompt Messages or Permissive Messages on the displays of microFlow net Gas or provide information to be printed out on the Bill of Lading Emulation When adding or changing information in these alphanumeric program codes the keys listed below perform the following functions KEY DESCRIPTION ENTER Moves the character from the character set to the ID line Also enters the data into the instrumen...

Страница 16: ...essed from the Program Mode Main Menu The Diagnostics menu available through the Main Menu consists of the following Active Alarms Alarm History Event Log Batch Record Log Audit Trail Digital Inputs Digital Outputs Analog Inputs Pulse Inputs Communications Monitor Download Directory Boolean Algebraic Batch Log Stats Summary Data Software Version Ultrasonic Data Contrast Adjust Active Alarms The Di...

Страница 17: ...s will allow the operator to page through the Alarm History displays If More is not displayed then there is only one screen of alarms in the alarm history Pressing the CLEAR key will revert to the Diagnostic menu Event Log The View Only Diagnostics menu displays Event Log where past events can be viewed With the arrow in front of Event Log pressing ENTER will display the last event that occurred i...

Страница 18: ...gebraic Batch 16 Batch Start Time 09 03 99 9 58 59 AM Batch End Time 09 03 99 10 02 24 AM Pulse Batch Fwd 0 Press PRINT for help Batch 16 IV Batch Fwd MCF 0 0000 GV Batch Fwd 0 000 MCF GST Batch Fwd 0 000 MCF GSV Batch Fwd 0 0000 MCF Press PRINT for help Batch 16 Energy Batch Fwd MMBtu 0 0000 Mass Batch Fwd kg 0 0000 Pulses Batch Rev 0 Press PRINT for help Batch 16 IV Batch Rev 0 00 MCF GV Batch R...

Страница 19: ... PRINT for help Batch 16 Avg Heat Value 0 000 Avg Mole Methane 100 00 Avg Mole Ethane 0 0000 Press PRINT for help Batch 16 Avg Mole Propane 0 0000 Avg Mole n Butane 0 0000 Avg Mole i Butane 0 0000 Press PRINT for help Batch 16 Avg Mole n Pentane 0 0000 Avg Mole i Pentane 0 0000 Avg Mole n Hexane 0 0000 Press PRINT for help Batch 16 Avg Mole n Heptane 0 0000 Avg Mole n Octane 0 0000 Avg Mole n Nona...

Страница 20: ...drogen 0 0000 Press PRINT for help Batch 16 Avg Mole CO 0 0000 Avg Mole Oxygen 0 0000 Avg Mole Helium 0 0000 Press PRINT for help Batch 16 Avg Mole Argon 0 0000 Prompt 1 Response 0 Prompt 2 Response 0 Press PRINT for help Batch 16 Prompt 3 Response 0 Prompt 4 Response 0 Prompt 5 Response 0 Press PRINT for help Batch 16 Strt IV Non Reset F 0 MCF Strt GV Non Reset F 0 MCF Strt GSV Non Reset F 0 MCF ...

Страница 21: ...Fwd 0 MCF GSV Non Reset Fwd 0 MCF Energy Non Reset Fwd 0 MMBtu Press PRINT for help Batch 16 Mass Non Reset Fwd 0 kg Strt IV Non Reset R 0 MCF Strt GV Non Reset R 0 MCF Press PRINT for help Batch 16 Strt GSV Non Reset R 0 MCF Strt Energy Non Reset R 0 MMBtu Strt Mass Non Reset R 0 kg Press PRINT for help Batch 16 IV Non Reset Rev 0 MCF GV Non Reset Rev 0 MCF GSV Non Reset Rev 0 MCF Press PRINT for...

Страница 22: ...ws on the keypad will allow the operator to step through the audit trail Pressing the CLEAR key will display the Diagnostic menu Digital Inputs The Diagnostics menu provides for the selection of Digital Inputs where the current status of the digital inputs can be viewed With the arrow in front of Digital Input pressing ENTER will display the digital inputs the programmed function and their status ...

Страница 23: ...ut value Pressing the CLEAR key will display the Diagnostics menu Pulse Inputs The Diagnostics menu provides the selection Pulse Inputs where the meter pulses and the metered injector pulses are displayed With the arrow in front of Pulse Inputs pressing ENTER will display the pulse inputs Pressing the CLEAR key will display the Diagnostics menu Communications Monitor The Diagnostics menu provides ...

Страница 24: ...n to the Live View display When completed press CLEAR until the Diagnostics menu is displayed Download Directory This directory will give a listing of all files that have been downloaded from the Flowmate Some examples would be Translations Configurable Batch Reports factory default also html web pages Boolean Equations etc Simply press ENTER on the menu to view the listing and use the up and down...

Страница 25: ...owmate Using the up and down arrow keys all fifty User Algebraic Registers can be viewed Pressing CLEAR will return to the Boolean Algebraic Processing menu Equation Line State The Equation Line Status displays the current status of the equations where D indicates that the equation is dis abled T is True and F is False All equations without an IF statement will have a True status Those with an IF ...

Страница 26: ...isplays how much was delivered and the associated pulses from the meter for the batch in progress If a new batch is started only the current batch information will be shown Software Version The Diagnostics menu provides the selection Software Version which allows the operator to view the version of software that is running in the microFlow net Gas With the arrow in front of Software Version pressi...

Страница 27: ...sing the Up and Down arrow keys select the diagnostic SW Version Identifies the software running in the ultrasonic meter Press Clear to return to the Ultrasonic Data Diagnostic Menu Status This screen indicates the following statuses Software Version microFlow Rev 00 00 CRC 850CCEE B Bootloader Rev 00 02 MAC 00 50 C2 XX XX XX Copyright 2007 2009 FMC Technologies Inc Ultrasonic Data SW Version Stat...

Страница 28: ... Meter Provides the flow velocity of the fluid at each path of the ultrasonic meter Press CLEAR to return to the Path Info display Provides the velocity of sound for each path of the ultrasonic meter Press CLEAR to return to the Path Info display Provides the velocity of sound for each path of the ultrasonic meter Press CLEAR to return to the Path Info display Section V Diagnostics VOS Path 2 0000...

Страница 29: ...arameters Section V Diagnostics Sig Path Info Signal 1A 000000 Signal 1B 000000 Signal 2A 000000 Signal 2B 000000 Signal 3A 000000 Signal 3B 000000 Sig Path Info Signal 4A 000000 Signal 4B 000000 Signal 5A 000000 Signal 5B 000000 Signal 6A 000000 Signal 6B 000000 Gain 1 3 Gain 1A 00000000 Gain 1B 00000000 Gain 2A 00000000 Gain 2B 00000000 Gain 3A 00000000 Gain 3B 00000000 Gain 4 6 Gain 4A 00000000...

Страница 30: ...ER FAILURE CALCULATION ERROR SIGNAL LOW ALARM GAIN ERROR ALARM VOS DIFFERENCE ALARM PATH SUBSTITUTION ALARM PARAMETER ERROR SOUND TO NOISE RATIO LOW HIGH TURBULENCE ALARM PROFILE DEVIANCE ALARM Press Clear to return to the Ultrasonic Data Diagnostic Menu Press Clear to return to the Diagnostic Menu Contrast Adjust This diagnostics menu provides for adjusting the display contrast Press CLEAR to ret...

Страница 31: ... Boolean Algebraic 12 14 17 18 20 22 C Communications Monitor 12 19 Contrast Adjust 12 26 D Diagnostics 12 26 Diagnostics Ultrasonic 23 Digital Inputs 12 18 Digital Outputs 12 19 Displays and Controls 3 7 Download Directory 12 20 E Ethernet Connectivity 1 Event Log 1 12 13 F F1 9 F2 9 Flow Rate 1 5 8 K Keypad 3 8 9 M Main Menu 8 10 12 26 Main Menu Diagnostics 12 Meter Factor 1 N Numeric Data 8 11 ...

Страница 32: ...ge 28 Section VI Index P Passcode 8 13 Power Fail 13 Power Up 8 Product Description 1 Program Mode 9 11 R Reset Batch 8 10 Run Mode 2 3 8 S Software Version 12 22 23 T Temperature 6 8 26 Transaction 8 13 U Ultrasonic Diagnostics 23 ...

Страница 33: ...fmctechnologies com measurementsolutions When requesting literature from Literature Fulfillment please reference the appropriate bulletin number and title microFlow net Gas Specification Bulletin SS06049 Installation Manual Bulletin MNFG001 Operator Reference Manual Bulletin MNFG002 Operations Manual Bulletin MNFG003 Calculations Bulletin TPFG001 Section VII Related Publications ...

Страница 34: ...d click on the Contact Us link in the left hand column Headquarters 500 North Sam Houston Parkway West Suite 100 Houston TX 77067 USA Phone 1 281 260 2190 Fax 1 281 260 2191 Gas Measurement Products Erie PA USA 1 814 898 5000 Ellerbek Germany 49 4101 3040 Thetford England 44 1842 822900 Kongsberg Norway 47 32 28 67 00 Buenos Aires Argentina 54 11 4312 4736 Integrated Measurement Systems Corpus Chr...

Отзывы: