background image

ROTARY HAMMER  

FPB 1500

User Manual

ID: #05007

m

yha

nsecontrol.

co

m

M

A

N

UA

DE

VELO

PED IN

 GE

RM

A

N

Y

User-friendly

Manual

Original instructions

Summary of Contents for FPB 1500

Page 1: ...ROTARY HAMMER FPB 1500 User Manual ID 05007 m y hansecontrol c o m M A N U A L DEVELOPED IN G E R M A N Y User friendly Manual Original instructions...

Page 2: ...ll and package contents 17 Inserting a tool 17 Removing a tool 18 Mounting and adjusting the depth stop 18 Setting the extra handle 18 Operation of the rotary hammer drill 18 Switching the rotary hamm...

Page 3: ...3 Package contents Dok Rev Nr 197392_20190710 A 1 2 3 5 7 6 4 8 10 9 B Package contents...

Page 4: ...4 Package contents 13 12 11 10 C D 14 15...

Page 5: ...5 Package contents NOTICE The keyed chuck may only be used without the hammer function Spiral and wood drill bits are not included in the package contents E F G 17 16...

Page 6: ...rd 5 Extra handle front handle 6 Retaining bush 7 Tool holder SDS plus system chuck 8 Gear grease filler hole 9 Wing screw for depth stop 10 Depth stop 11 SDS chisel 2 1 flat chisel 1 pointed chisel 1...

Page 7: ...le local or national regulations concerning the use of this rotary hammer drill Keep this user manual in a safe place for future reference If you pass the rotary hammer drill on to third parties pleas...

Page 8: ...secure footwear Wear suitable protective gloves Protection class II Drilling in wood and metal without the hammer function Hammer drilling in concrete and masonry Setting the working angle ben auf ne...

Page 9: ...ial use The tool holder is suitable for tools corresponding to the SDS plus system Any other applications are expressly prohibited and are deemed improper use Improper use All applications with the de...

Page 10: ...sible speed is not at least as high as the maximum speed specified for the rotary hammer drill Accessories that rotate faster than permissible may break and be projected There is a risk of injury The...

Page 11: ...ted you could lose control of the power tool Electrical safety a Power tool plugs must match the outlet Never modify the plug in any way Do not use any adapter plugs with earthed grounded power tools...

Page 12: ...ool Carrying power tools with your finger on the switch or connecting the power tool to a power supply while the switch is set to on may lead to accidents d Remove any adjusting key or wrench before t...

Page 13: ...this power tool Power tools are dangerous in the hands of untrained users e Maintain power tools and insertion tools with care Check for misalignment or binding of moving parts breakage of parts and a...

Page 14: ...ock Afaultyelectricalinstallationorexcessivemainsvoltagemayresultinanelectric shock Only connect the rotary hammer drill if the mains voltage of the socket corresponds to the data on the rating plate...

Page 15: ...Wear work gloves to prevent your fingers from being crushed and to prevent skin abrasions Only connect the rotary hammer drill to the power supply after it has been switched off Make sure that the ro...

Page 16: ...attempt to clean the rotary hammer drill by immersing it in water and do not use a steam cleaner to clean it Otherwise you could damage the rotary hammer drill Do not use aggressive solvents to clean...

Page 17: ...tool holder is suitable for tools in accordance with the SDS plus system Inserting a tool The drill bit and chisel with a shaft corresponding to the SDS plus system can be inserted directly into the t...

Page 18: ...setting by tightening the wing screw The front end of the depth stop will come into contact with the respective base once the set drilling depth is reached 5 Drill a test hole if necessary Setting th...

Page 19: ...waterlines There is a risk of electrocution gas emission and water damage Before drilling into walls and masonry check that they do not contain power gas or water lines Always use both hands to hold t...

Page 20: ...ay damage the rotary hammer drill Only switch between hammer drilling and normal drilling if the rotary hammer drill and the inserted tool have come to a stop Only use the keyed chuck without the hamm...

Page 21: ...ing A pneumatic impact mechanism generates the required impact for hammer drilling in rock This electropneumatic principle generates a high level of hammer elasticity and permits recoilless work Unlik...

Page 22: ...rotary hammer drill Check the condition of the rotary hammer drill regularly Among other things check to make sure that the switches are not damaged that the accessories are in proper condition that t...

Page 23: ...1 Use a soft cloth or brush to clean the housing 2 Clean the vents and the area around the tool holder 7 3 Remove dust chips by blowing them out with compressed air Storage 1 Clean the rotary hammer d...

Page 24: ...he selector switch to the symbol indicating Drilling without the hammer function or Hammer drilling The drill bit 12 does not pene trate the material to be drilled into The hammer function has been de...

Page 25: ...voltage 230 240 V 50 Hz Nominal output 1 500 W Protection class II Idle speed 0 850 min 1 Number of strokes without load 0 3 900 min 1 Impact energy 5 J Max drill diameter in wood in concrete rock gr...

Page 26: ...e may exceed 85 dB A protective measures are necessary in this case wear suitable ear protection Chiselling Sound pressure level LpA 93 dB A Sound power level LwA 104 dB A Uncertainty K 3 dB A Hammer...

Page 27: ...e g periods in which the power tool is switched off and times when the power tool is switched on but is running without load Try to keep the noise and vibration exposures as low as possible Wearing g...

Page 28: ...uct must be handed in at a collection point intended for the purpose This can occur for example by handing it in at an authorised collecting point for the recycling of waste electrical and electronic...

Page 29: ...laration of Conformity GB Wuppertal 04 04 2019 Ingo Heimann M Sc Technical direction Product development Conmetall Meister GmbH Oberkamper Stra e 37 39 42349Wuppertal Germany Authorized person for sto...

Page 30: ...re within its intended use over the course of the first 3 years after date of purchase we will remedy the problem as quickly as possible once it has been brought to our attention In the unlikely event...

Reviews: