2 WIRE SYSTEM 

FVQ-6020APP KIT 

FVQ-6020 KIT 

 

VIDEO DOOR PHONE SYSTEM 

FVQ-6016KP 

FVQ-6013/9013WIFI 

Please read the manual carefully before using the product. 

Please note that images and sketches in this manual may be different from the actual products 

INSTALLER MANUAL 

Summary of Contents for FVQ-6020

Page 1: ...FVQ 6020 KIT VIDEO DOOR PHONE SYSTEM FVQ 6016KP FVQ 6013 9013WIFI Please read the manual carefully before using the product Please note that images and sketches in this manual may be different from the actual products INSTALLER MANUAL ...

Page 2: ...iption 4 Addressing the monitors When using more than one monitor 5 Impedance Switch 5 Viewing Multiple Door Stations On The Monitor 6 Wiring Diagrams 7 Lock Wiring 16 Summary Keypad door station codes 23 Detailed Keypad Codes 24 Wi Fi Configuration 27 ...

Page 3: ...enabled 4 Message Indicator Green LED when you have missed calls 5 Microphone 6 Screen 7 Inch Digital TFT LCD 7 Switch Bit 1 Bit 5 Home address Bit 6 Bit 7 Master and slave selection 8 Connection Point BUS1 BUS2 System connection bus 24V GND External Power supply Not needed COM NO Connector for external speaker SW SW Connector for external door bell 9 Speaker ...

Page 4: ...4 Door Station Description NO Name 1 Status Indicator 2 Camera 3 Speaker 4 Keypad 5 LED s Sensor located in middle 6 Microphone 7 Fixing screw 8 Connection Port ...

Page 5: ...or Type Dip Switch Setting Master Monitor Slave Monitor 1 Slave Monitor 2 Slave Monitor 3 Impedance Switch Only turn to the on position when the monitor is the end of line This is controlled by dip switch 8 on the back of the monitor Type Dip Switch Setting Impedance Off Impedance On 6 7 ON 6 7 ON 6 7 ON 6 7 ON 8 ON 8 ON ...

Page 6: ...ed to activate the door station to view on the monitors Using the settings menu on each individual monitor type in the following code depending how many door station you have Default 4 Door Stations Door Station Code On Code Off DS 1 0111 0110 DS 2 0131 0130 DS 3 0151 0150 DS 4 0171 0170 ...

Page 7: ...sing more than 1 door station you require a 4 branch Door station module FVQ 6012D When using more than 1 monitor in star configuration you require a 4 branch monitor module FVQ 6011M Door Station is addressed as number 1 by default ...

Page 8: ...8 1 Door Station to 4 Monitors Star Configuration ...

Page 9: ...9 ...

Page 10: ...10 1 Door Station to 3 Monitors Series ...

Page 11: ...11 ...

Page 12: ...12 4 Door Station to 4 Monitors Star Configuration ...

Page 13: ...13 ...

Page 14: ...14 4 Door Station to 3 Monitors Series ...

Page 15: ...15 ...

Page 16: ...t on exit or door release o Lock 1 is only power to unlock Lock 2 Dry Collector that can be toggled between Normally Open or Normally Closed The Exit button can be configured in 3 Modes Default is Lock 1 Lock 2 Only Lock 1 Only Lock 2 Lock 1 and Lock 2 DEFAULT MODE ...

Page 17: ...17 Power to Unlock Power to Lock Lock 1 N A Lock 2 Exit Button To Open Lock 1 Lock 2 ...

Page 18: ...18 Power to Unlock Power to Lock Lock 1 N A Lock 2 Exit Button To Open Lock 1 Lock 2 ...

Page 19: ...19 Power to Unlock Power to Lock Lock 1 N A Lock 2 Exit Button To Open Lock 1 Lock 2 Normally Closed ...

Page 20: ...20 Power to Unlock Power to Lock Lock 1 N A Lock 2 Exit Button To Open Lock 1 Lock 2 ...

Page 21: ...21 Power to Unlock Power to Lock Lock 1 N A Lock 2 Exit Button To Open Lock 1 Lock 2 Independent Exit button ...

Page 22: ...22 Power to Unlock Power to Lock Lock 1 N A Lock 2 Exit Button To Open Lock 1 Lock 2 Independent Exit button Normally Closed ...

Page 23: ...ck 1 2 Only 1234 05 2 Exit Button Delay to Activate 14 5 Seconds 1234 14 10 Door Station Address 11 Door Station 1 1234 11 1 Door Station 2 1234 11 2 Door Station 3 1234 11 3 Door Station 4 1234 11 4 Delete All Users 00 1234 00 Change Master Code 01 Change code to 9876 1234 01 9876 Temporary Password Lock 1 56 59 Lock 2 60 63 Lock 1 1111 1234 56 1111 Lock 2 2222 1234 60 2222 Talk Volume 10 Level 3...

Page 24: ... 10 seconds XX is divided by 2 for seconds E G For an Lock 1 opening time of 7 seconds press 1234 04 14 Lock 2 lock time Default 7 seconds Input master code 1234 by default and press 03 input XX where XX goes from 1 0 5s 2 1s 20 10 seconds XX is divided by 2 for seconds E G For an Lock 2 opening time of 7 seconds press 1234 03 14 Exit Button unlock Default 2 seconds Input master code 1234 by defau...

Page 25: ...Input master code 1234 by default and press then choose the lock group Lock 1 starts from 56 up to 59 Lock 2 starts from 60 up to 63 Press then input an access code from 4 up to 12 digits and press Finally press to exit It is recommended to keep a list of users address for future reference No duplications allowed with any other codes After successfully unlocking the door the code will delete after...

Page 26: ... 1 Door station ringtone OFF Default mode is On E G On 1234 15 0 Off 1234 15 1 Keypad Lights Input master code 1234 by default and press 02 type X where X is 0 Keypad lights on 1 Keypad lights Off Default mode is On If setting is on they will still only turn on during night time E G On 1234 2 0 Off 1234 1 1 ...

Page 27: ...27 Wi Fi Configuration For latest up to date instructions please visit www fermaxaus com au Please download the Fermvision Wifi Smart phone application ...

Page 28: ... To clean the LCD screen using hands or a wet cloth is forbidden To clean the equipment use a soft cotton cloth No organic or chemical detergent Image distortion may occur if the video door phone is mounted too close to magnetic fileds e g microwaves TV fridges Please keep away the video door monitor from wet high temperature dust and caustic and oxidation gas in order to avoid any unpredictable d...