background image

I

UK

   S P E A K E R     S Y S T E M S

User's Manual

Manuale d'uso

VENTIS 112MA 

Processed Active Monitor

VENTIS 115MA 

Processed Active Monitor

VENTIS 112M 

Passive Reinforcement Monitor

VENTIS 115M 

Passive Reinforcement Monitor

Summary of Contents for VENTIS 112M

Page 1: ...E A K E R S Y S T E M S User s Manual Manuale d uso VENTIS 112MA Processed Active Monitor VENTIS 115MA Processed Active Monitor VENTIS 112M Passive Reinforcement Monitor VENTIS 115M Passive Reinforcement Monitor ...

Page 2: ...STALLAZIONE INSTALLATION MODES DIMENSIONI DIMENSIONS CONTROLLI E FUNZIONI CONTROLS AND FUNCTIONS DSP Descrizione del menu Menu description Controllo dei parametri di sistema System parameters control Descrizione delle voci del menu principale Description of the main menu items CARATTERISTICHE TECNICHE TECHNICAL SPECIFICATIONS 1 2 3 4 5 5 6 7 8 9 10 11 11 12 13 14 15 16 17 ...

Page 3: ...IMPORTANTI ISTRUZIONI DI SICUREZZA IMPORTANT SAFETY INSTRUCTIONS AVVERTENZE WARNINGS 1 ...

Page 4: ...lità push to select 6 preset offrono la soluzione ideale per soddisfare una ampia varietà di usi per ogni esigenza Versione attiva Active version Versione passiva Passive version 2 The new VENTIS bass reflex coaxial monitors extend the active and passive range of the series Equipped with custom B C transducers and built in 15mm multilayer birch they can also be used for fixed and FOH installation ...

Page 5: ...ce coil 1 exit throat B C HFcompression driver with 1 7 voice coil Frequency response from 50Hz to 20kHz Dispersion 90 Wall bracket mount thread optional 1 38 top heat Two integrated handles 0 59 birch plywood enclosure 700W 200W RMS 3 PASSIVE REINFORCEMENTMONITOR 500W 8 Ohm Crossover passivo interno con protezione soft trip su WF eTW Connettori Speakon NL 4 IN LINK out Risposta in frequenza da 55...

Page 6: ...oice coil 1 exit throat B C HFcompression driver with 1 7 voice coil Frequency response from 55Hz to 20kHz Dispersion 90 Wall bracket mount thread optional 1 38 top heat Two integrated handles 0 59 birch plywood enclosure 700W 200W RMS PASSIVE REINFORCEMENTMONITOR 400W 8 Ohm Crossover passivo interno con protezione soft trip su WF eTW Connettori Speakon NL 4 IN LINK out Risposta in frequenza da60H...

Page 7: ...ord supplied since the power cord can only support a maximum current of 16A POWER SUPPLY120V If the total current demand does not exceed 15A use the power cable supplied If the total current demand is between 15A and 20A user the power cable THE CABLE AND THE PLUG MUST HOLD THE UL OR CSA CERTIFICATION AWG12 SJT VW1 with plug rated current equal or greater than 30A The PowerCon True 1 system is cer...

Page 8: ...ri causati dall accensione delle apparecchiature audio a monte dei diffusori è buona regola che i diffusori amplificati e gli amplificatori collegati siano sempre le ultime apparecchiature ad essere accese dopo il montaggio e le prime ad essere spente alla fine dello spettacolo Solo a questo punto potete accendere il diffusore e alzare il controllo del livello Before turning on the speaker make su...

Page 9: ...ACCESSORI ACCESSORIES VENTIS VENTIS 7 VN U115M VN U112M 628mm 24 72 528mm 20 78 70mm 2 75 325mm 12 79 90 90 70mm 2 75 460mm 18 11 560mm 22 04 290mm 11 41 VN C112M VN C115M Ventis 115MA M Ventis 112MA M ...

Page 10: ... MURO SUSPENSION BY WALL BRACKET Carefully choose the area where speakers will be installed making sure that the structure can support the system weight Remove the speaker s rubber feet A and the stand adapter B Fix the flange supplied instead of the adapter C Secure the bracket to the wall by using screws in all its fixing holes Place the speaker between bracket arms and secure it through two M10...

Page 11: ...ctive Monitor VENTIS 115MA Processed Active Monitor VENTIS 112M Passive Reinforcement Monitor VENTIS 115M Passive Reinforcement Monitor 620mm 24 40inch 516 5mm 20 33inch 342mm 13 46inch 551mm 21 69inch 452 5mm 17 81inch 299 5mm 11 79inch 48 55 48 55 ...

Page 12: ...i esterne come ad esempio MP3 player 9 Prese Speakon collegate in parallelo utilizzare una presa per il collegamento del diffusore all uscita di un amplificatore di potenza l altra per collegare un secondo diffusore 1 Menu display and DSPsettings 2 General digital volume to control the level of mixed signals Press to access the DSPmenu and turn the knob to select parameters 3 Output signal mode se...

Page 13: ...e System protection Indicatori di guasto Fault controls AMPLIFIER PROTECT In caso di malfunzionamento il display fornisce indicazioni della possibile causa discernendo tra cause termiche segnalate come THERMAL PROTECT o guasti generici dell amplificatore segnalati comeAMPLIFIER PROTECT Fig 2 indicatori di guasto 1 PRESET Preset settings 2 EQUALISATION By default all filter gains are set to zero On...

Page 14: ...em requested by turning the knob 3 Press the knob to select the item you want to edit The sub menu item will be displayed in the right column certain items may open a new menu window if the editing options concern a higher number of variables as in the case of the three band equaliser ORIGINAL 4 Ricercare la voce desiderata ruotando la manopola 5 Premere per confermare la scelta ed applicare le mo...

Page 15: ...13 ...

Page 16: ... voce di ritorno alla pagina precedente BACK Di default i valori sono tutti impostati a zero Gain adjustment function of the 3 band equaliser The selection opens a new window where you can adjust the gains of the three tone filters Low Mid High with item to go back to the previous page BACK The default values are all set to zero 14 High pass filter frequency input function selection which is usefu...

Page 17: ...iere se abilitare il LOCK con le istruzioni per lo sblocco tali istruzioni in modalità LOCKED verranno indicate a schermo ad ogni tentativo di accesso per mezzo della manopola MASTER VOL LOCK SCREEN ARE YOU SURE Fig 8 finestra di blocco schermo YES NO TO UNLOCK THE MENU PRESS AND HOLD THE MENU BUTTON FOR 5 SECONDS Menu lock function which prevents accidental changes to settings of DSP Selection op...

Page 18: ...e La selezione apre una nuova finestra in cui viene chiesta conferma per l esecuzione del RESET RESET Fig 9 ripristino ai dati di fabbrica RESET TO FACTORY SETTINGS BACK YES Function to reset default settings delete all customised settings made by the user Selection opens a new window where you will be asked to confirm execution of RESET Fornisce le informazioni generiche sul diffusore nome versio...

Page 19: ...000 800 55Hz 18kHz 60Hz 18kHz 90 90 44 75 36 37 49 16 40 78 1 x 15 coil 2 5 1 x 12 coil 2 5 1 x 25 bobina 44 1 x 25 bobina 44 1 x 1 coil 1 7 1 x 1 coil 1 7 127 132 126 132 16 40 16 40 1 x 15 coil 2 5 1 x 12 coil 2 5 1 x 25 bobina 44 1 x 25 bobina 44 1 x 1 coil 1 7 1 x 1 coil 1 7 126 130 125 129 1 4 50Hz 24dB oct 45Hz 24dB oct 50Hz 24dB oct 45Hz 24dB oct 620 x 342 x 516 5 551 x 299 5 x 452 5 24 40 ...

Page 20: ...CODE 41413 28062017 ...